Based on magnetron sputtering deposition technology, titanium (Ti) thin films are deposited on silicon (Si) substrate using different preparation conditions such as sputtering power and pressure. The influence of altering these conditions on deposition rate and microstructure is studied. The results show that sputtering power significantly affects the rate of deposition and the resistivity. The deposition rate of the Ti thin film increases when the resistivity decreases under sputtering powers of 150–225 W with a pressure of 0.8 Pa and Argon (Ar) flux of 80 sccm. As sputtering power was increased further (from 225 to 250 W), the deposition rate reduced and the resistivity augmented. Pressure also has influence on the deposition rate and resistivity – when pressure increases from 0.6 to 0.8 Pa, the deposition rate escalates while the resistivity reduces; when the pressure is raised from 0.8 to 1.0 Pa with Ar flux of 100 sccm, the deposition rate decreases and resistivity increases. The surface chemical compositions and the structures of the Ti film were studied by using X-ray photoelectron spectroscopy (XPS) and X-ray diffractometer (XRD). Observing the cross-section of the thin-film samples produced by scanning electron microscope (SEM) reveals the influence of the preparation conditions used on the microstructure and confirms the influence of sputtering power and pressure on the resistivity.
In digital holographic microscopy, the quantitative phase image suffers from phase aberrations and coherent noises. To solve these problems, two independent steps are applied sequentially in the reconstruction procedure to compensate for the phase aberrations and denoising. Here we demonstrate for the first time, to the best of our knowledge, that the reconstruction process can be simplified by replacing the two step methods with a deep learning-based algorithm. A convolutional neural network is trained simultaneously for phase aberration correction and denoising from an only wrapped phase map. In order to train the network, a database consists of massive wrapped phase maps as input, and noise-free sample phase maps as labels are constructed. The generated wrapped phase maps include a variety of phase aberrations and faithful coherent noises that are reconstructed from a practical apparatus. The trained network is applied to correct phase aberrations and denoise of both simulated and experimental data for the quantitative phase image. It exhibits excellent performance with output comparable to that reconstructed from the double exposure method for phase aberration correction followed with block-matching and 3D filtering for denoising, while outperforming other conventional two step methods.
Retrieving a phase map from a single closed fringe pattern is a challenging task in optical interferometry. In this paper, a convolutional neural network (CNN), HRUnet, is proposed to demodulate phase from a closed fringe pattern. The HRUnet, derived from the Unet model, adopts a high resolution network (HRnet) module to extract high resolution feature maps of the data and employs residual blocks to erase the gradient vanishing in the network. With the trained network, the unwrapped phase map can be directly obtained by feeding a scaled fringe pattern. The high accuracy of the phase map obtained from HRUnet is demonstrated by demodulation of both simulated data and actual fringe patterns. Compared results between HRUnet and two other CNNS are also provided, and the results proved that the performance of HRUnet in accuracy is superior to the two other counterparts.
Computed tomography of chemiluminescence (CTC) is an effective technique for three-dimensional (3D) combustion diagnostics. It reconstructs the 3D concentrations of intermediate species or 3D images of flame topology by multiple chemiluminescence projections captured from different perspectives. In the previous studies of CTC systems, it was assumed that projections from arbitrary perspectives are available. However, for some practical applications, the range of view angles and the number of projections might be restricted due to the optical access limitation, greatly affecting the reconstruction quality. In this paper, the exact reconstruction condition for angle-limited computed tomography of chemiluminescence was studied based on Mojette transform theories, and it was demonstrated by numerical simulations and experiments. The studies indicate that the object tested within limited angles can be well reconstructed when the number of grids, the number of projections, and the sampling rate of projections satisfy the exact reconstruction condition. By increasing the sampling rate of projections, high-quality tomographic reconstruction can be achieved by a few projections in a small angle range. Although this technique is discussed under combustion diagnostics, it can also be used and adapted for other tomography methods.
Computed tomography of chemiluminescence (CTC) is an effective tool for combustion diagnostics by using optical detectors to capture the projections of luminescence from multiple views and realizing the three-dimensional (3D) reconstruction by computed tomography (CT) theories. In the existing CTC, ordinary commodity lenses were employed in the system for imaging, the imaging effects complicate the projection model and the low sampling rate decreases the spatial resolution and reconstruction accuracy. In classical CT techniques, parallel projection based on 2D Radon transform is the simplest model, which has been widely used in CT applications. In this work, double telecentric lens is introduced in CTC to realize the acquisition of parallel projection with high sampling rate. Despite the parallel projection CT theories have been well studied, there are still a few theoretical and technological drawbacks need to be solved when utilizing double telecentric lens in CTC. Firstly, a simple method based on bilinear interpolation is studied to improve the calculation accuracy of the weight matrix. Secondly, the exact reconstruction condition for parallel projections is studied based on the discrete Radon transform theory. It establishes the theoretical relationship of the reconstruction quality and the sampling rate of the projections, the number of views, the range and the spatial resolution of the reconstructed region. In experiment, camera calibration technique for double telecentric lens is studied, and the results of which are used for projection correction. The tomographic reconstructions of an axisymmetric flame demonstrate the feasibility and accuracy of the studies.
In order to study the effect of temperature fields on the microstructure, optical properties and response to laser damage of La2Ti2O7 films, a group of films were prepared by electron beam evaporation using the same parameters on Si and fused silica substrates. Then, rapid thermal annealing at different temperatures was applied to simulate the application of a temperature field. The structure, optical constants and response to laser damage of La2Ti2O7 films were investigated by XPS, XRD, ellipsometry and laser damage testing. The results showed that Ti4+ is gradually converted to Ti3+ with increasing temperature resulting in a higher refractive index, larger extinction coefficient and more serious absorption. When the temperature was higher than 800oC, the loss of oxygen was more pronounced. The density of annealed films first increased and then decreased when the temperature rises from 600 to 1000oC, and reached its maximum at 800oC. And the crystallization, oxygen loss and densification were found to be related to the laser damage threshold of La2Ti2O7 film. The laser damage threshold of the film decreased sharply when the temperature is above 900oC.