Steve Policastro

Dr. Steve Policastro

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 July 2017 in The Journal of Physical Chemistry C
Verified
Journal Article
Open access
MGMitchell C. Groenenboom
Mitchell C. Groenenboom
RARachel M. Anderson
Rachel M. Anderson
DHDerek J. Horton
Derek J. Horton
YBYasemin Basdogan
Yasemin Basdogan
DRDonald F. Roeper
Donald F. Roeper
JKJohn A. Keith
John A. Keith
The oxygen reduction reaction (ORR) is a major factor that drives galvanic corrosion. To better understand how to tune materials to better inhibit catalytic ORR, we have identified an in silico procedure for predicting elemental dopants that would cause common, natively formed titanium oxides to better suppress this reaction. In this work, we created an amorphous TiO2 surface model that is in good agreement with experimental radial distribution function data and contains reaction sites capable of replicating experimental ORR overpotentials. Dopant performance trends predicted with our quantum chemistry model mirrored experimental results, and our top three predicted dopants (Mn, Al, and V, each present at doping concentrations of 1%) were experimentally verified to lower ORR currents under alkaline conditions by up to 77% vs the undoped material. These results show the robustness of calculated thermodynamic descriptors for identifying poor, TiO2-based ORR catalysts. This also opens the possibility of using quantum chemistry to guide the design of coating materials that would better resist the ORR and presumably galvanic corrosion.

22 July 2023 in Coatings
Verified
Journal Article
Open access
PDF file
SPSteve Policastro
Steve Policastro
RARachel M. Anderson
Rachel M. Anderson
CHCarlos M. Hangarter
Carlos M. Hangarter
AAAttilio Arcari
Attilio Arcari
EIErick B. Iezzi
Erick B. Iezzi
Electrochemical impedance spectroscopy (EIS) is a widely used method for monitoring coatings because it can be done in situ and causes little damage to the coating. However, interpreting the impedance data from coatings in order to determine the state of the coating and its protective abilities is challenging. A modified version of the rapid electrochemical assessment of paint (REAP) equivalent circuit is developed here, along with a method to calculate the impedance of a circuit using matrix algebra. This new equivalent circuit and the calculation method are used to analyze EIS data obtained from a two-layer commercial organic coating system immersed in NaCl solutions with different concentrations and at different temperatures. The matrix calculation method is validated by comparing results obtained from commercial analysis software to this method for two different equivalent circuits, and the parameter values are nearly equal. Physics-based models of the equivalent circuit elements are derived and used to obtain both initial estimates for the regressions and physics-based constraints on the model parameters. These models are integrated into the regression procedure, and the corrected Akaike information criterion (AICc) is used to compare fits between the new circuit and classic equivalent circuits. The AICc values indicate the new circuit results in better fits than classic equivalent circuits used for coatings analysis.

1 April 2021 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
SPSteve Policastro
Steve Policastro
RARachel M. Anderson
Rachel M. Anderson
CHCarlos M. Hangarter
Carlos M. Hangarter
Measurements of galvanic corrosion between UNS S13800 and UNS A97075 in bulk and equilibrated droplet electrolytes are compared with theoretical predictions of the corrosion current using calculations of the static diffusion-limited current, the classic Cottrell equation, and chemical reaction pathway models. The droplet electrolyte experiments use disks of stainless steel embedded in the aluminum alloy but isolated from electrical contact by an epoxy ring and connected via a zero-resistance ammeter potentiostat. Discrepancies between the measured and expected corrosion current for the droplet electrolyte are analyzed and a mechanism that relies on chemical reactions in the electrolyte to form corrosion products that block ion transport and suppress further oxidation is proposed. Electrochemical impedance spectroscopy and mass measurements are used to monitor changing solution properties in the equilibration of the droplet with the temperature and relative humidity environment of the atmospheric corrosion chamber.

9 May 2023 in Materials
Verified
Journal Article
Open access
PDF file
SPSteve Policastro
Steve Policastro
RARachel M. Anderson
Rachel M. Anderson
CHCarlos M. Hangarter
Carlos M. Hangarter
AAAttilio Arcari
Attilio Arcari
EIErick B. Iezzi
Erick B. Iezzi
Water uptake by organic coating systems used for corrosion prevention on airframes is one of the principal contributors to the loss of barrier properties of the coating. We used equivalent circuit analyses of electrochemical impedance spectroscopy (EIS) data to track changes in coating layer capacitance for a two-layer coating system consisting of an epoxy primer and polyurethane topcoat immersed in NaCl solutions with different concentrations and temperatures. The capacitance curve exhibited two different response regions, consistent with the “two-stage kinetics” mechanisms for water uptake by the polymers. We tested several numerical diffusion models of water sorption and found the most successful to be one that varied the diffusion coefficient as a function of polymer type and immersion time and accounted for physical aging processes in the polymer. We employed the Brasher mixing law along with the water sorption model to estimate the coating capacitance as a function of water uptake. The predicted capacitance of the coating was found to be consistent with the capacitance obtained from the EIS data, which is consistent with theories that water uptake occurs via initial rapid transport followed by a much slower aging process. Thus, both these water uptake processes need to be considered when making EIS measurements to assess the state of a coating system.

1 April 2023 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
SPSteve Policastro
Steve Policastro
RARachel M. Anderson
Rachel M. Anderson
CHCarlos M. Hangarter
Carlos M. Hangarter
A method for analyzing cathodic polarization curves on stainless steels is described and a framework for predicting the cathodic polarization response for UNS S13800 is developed, including a model for the diffusivity of dissolved oxygen as a function of chloride concentration and temperature. The cathodic polarization behavior of UNS S13800 in NaCl solutions, ranging from dilute to saturated, and across a range of temperature values was studied using potentiodynamic polarization, electrochemical impedance spectroscopy (EIS), and X-ray photoelectron spectroscopy (XPS). Analysis of the data indicated that the concentration of the solutions affected the ability of the oxide to catalyze reduction reactions. Dilute-to-low concentration solutions exhibited different Tafel slopes in the ORR-activation region while middle-to-high concentration solutions exhibited a single Tafel slope. The XPS and EIS results show a slightly thicker oxide formed in the low chloride concentration solutions over the course of the 18 hour open circuit duration along with a higher concentration of Fe3+ species.. The EIS data also showed the oxide formed in the low chloride solution had a higher charge-transfer resistance while the oxide formed in the high chloride solution had a higher oxide resistance.

14 June 2019 in Corrosion Reviews
Verified
Journal Article
Closed access
PDF file
SPSteve Policastro
Steve Policastro
CHCarlos M. Hangarter
Carlos M. Hangarter
RARachel M. Anderson
Rachel M. Anderson
FFFritz Friedersdorf
Fritz Friedersdorf
This work investigates the effects that the confined volume of atmospheric electrolytes has on the galvanic corrosion kinetics of a martensitic stainless steel alloy, UNS S13800, coupled with UNS A97075 in simulated atmospheric environments at relative humidity values that span the range of operational exposures. Restricted volumes found in thin films and droplets have been shown to control reduction reaction kinetics and are an ongoing challenge to characterize and standardize. This, along with the dynamic and high concentration of aggressive ions found in confined electrolytes, creates a unique corrosion system that requires a multifaceted approach to evaluate varied conditions, compare them with traditional measurements, and more accurately predict galvanic atmospheric corrosion. In this work, corrosion currents in galvanic couples were obtained under two environmental conditions: (1) bulk electrolytes, in a standardized test configuration, with chemistries relevant to atmospheric electrolytes; and (2) deliquesced droplets formed and equilibrated at a given temperature and relative humidity value. The corrosion currents for the same galvanic couple specimens were evaluated, using an atmospheric corrosion model, under a thin film electrolyte while statically loaded and unloaded, at two nominally different locations, e.g. Alexandria, VA, and Miami, FL, on the same date, using recorded weather conditions. The modeled corrosion currents were then compared with the currents obtained from the experimental conditions.