Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
Continuum robot is a class of robots renowned for its significant flexibility and manipulability. In recent years, tendon-driven robot, one type of continuum robots, is with compressible and extensible length and bigger working space compared with the non-extensible robot and can travel along the nonlinear spatial curved path. However, existing retractable robots mainly consist of a concentric-like tube, by which it is hard to construct a robot with arbitrary segments, due to the iterative reduction of diameters of multiple tubes and the constraint that diameters of tubes should not be over small to guarantee a necessary stiffness. In this paper, we present a novel tendon-driven continuum robot with extensible length to overcome this shortcoming. The key distinction is that the new design achieves extension based on wire-driven method rather than direct push-pull approach adopted in existing concentric robots. Therefore, continuum robot based on this new design shows higher flexibility and can be with arbitrary segments. Kinematic model of the robot are derived and its workspace is obtained for one and two bending modules. Prototype built demonstrates via experiments the contractible and extensible performance, and the maximal bending angle is measured through experiments. This type of continuum robot may be implemented in therapies for some clinical diseases, like neurosurgery and natural orifice transluminal endoscopic surgery (NOTES).
10 January 2022 in IEEE Robotics and Automation Letters
Surgical incision is a pervasive procedure in medical environments. Stapling is an incision closure method that is comparable to stitching. While incision closure is performed immediately after a surgery, staples are removed several weeks after the closure. The workload of surgeons and the probability of infections can be highly reduced if both stapling and staple removal procedures are accomplished by autonomous medical robots. This study proposes a medical robot system that can autonomously perform both the stapling of surgical incisions and the removal of staples after the stapled incision is healed. Individual module designs for stapling and removing staples are presented in detail. The modules were attached to an end-effector that was connected to the end joint of the manipulator. Based on binocular vision, a control method consisting of incision detection, staple position planning, and staple detection was developed to guide the robot to press the staples into a simulated piece of wounded skin and remove the staples from the same phantom. The experiments demonstrated that the prototypical robot effectively performed both stapling and staple removal tasks without human intervention.
2 February 2021 in IEEE Journal of Translational Engineering in Health and Medicine
Objective : To remove blood from an incision and find the incision spot is a key task during surgery, or else over discharge of blood will endanger a patient’s life. However, the repetitive manual blood removal involves plenty of workload contributing fatigue of surgeons. Thus, it is valuable to design a robotic system which can automatically remove blood on the incision surface. Methods : In this paper, we design a robotic system to fulfill the surgical task of the blood removal. The system consists of a pair of dual cameras, a 6-DoF robotic arm, an aspirator whose handle is fixed to a robotic arm, and a pump connected to the aspirator. Further, a path-planning algorithm is designed to generate a path, which the aspirator tip should follow to remove blood. Results : In a group of simulating bleeding experiments on ex vivo porcine tissue, the contour of the blood region is detected, and the reconstructed spatial coordinates of the detected blood contour is obtained afterward. The BRR robot cleans thoroughly the blood running out the incision. Conclusions : This study contributes the first result on designing an autonomous blood removal medical robot. The skill of the surgical blood removal operation, which is manually operated by surgeons nowadays, is alternatively grasped by the proposed BRR medical robot.
End effectors of laser ablation systems for minimally invasive surgery are crucial to the performance of integrated laser ablation systems. Due to the constraints imposed by millimeter-sized overall diameter, the designs of laser ablation end effectors are challenging. In this paper, a laser ablation end effector for minimally invasive surgery is designed and built. The proposed end effector is composed of a bending section, a ball joint mechanism and a micro imaging sensor. By actuating the bending section and the ball joint mechanism independently, the Nd:YAG laser beam with the wavelength of 1064nm is steered to desired directions within its workspace and irradiate target lesion points. The diameter of the laser ablating distal module is 5 millimeters and the maximal tilt angle of the ball joint mechanism is 26 degrees. Furthermore, based on the proposed end effector and auxiliary mechanical system, an autonomous laser ablating approach is established to coagulate lesion. This method is developed on a lesion's planar contour which is obtained by the small image sensor, and the coordinates of all planned ablating positions are calculated, satisfying that all lesion area are covered. The laser ablating method is verified by experiments.