Nonlinearity may cause a model deviation problem, and hence, it is a challenging problem for process monitoring. To handle this issue, local kernel principal component analysis was proposed, and it achieved a satisfactory performance in static process monitoring. For a dynamic process, the expectation value of each variable changes over time, and hence, it cannot be replaced with a constant value. As such, the local data structure in the local kernel principal component analysis is wrong, which causes the model deviation problem. In this paper, we propose a new two-step dynamic local kernel principal component analysis, which extracts the static components in the process data and then analyzes them by local kernel principal component analysis. As such, the two-step dynamic local kernel principal component analysis can handle the nonlinearity and the dynamic features simultaneously.
To overcome the shortage of traditional temperature sensors, this paper adopts infrared thermal imaging technology for temperature measurement. To avoid the spatial information loss issue during the image data vectorization process, this paper adopted the spatial relationship between pixels in principal component analysis (PCA) model training, which is called spatial information-based PCA (SIPCA). Then, spatial information is also used in the fault localization method to enhance the fault location performance. Tested by an experimental tank system, the proposed method achieves better performance than the traditional PCA approach, and it can detect heat leakage faults on the surface of the equipment.
17 March 2024 in The Canadian Journal of Chemical Engineering