François Jamar

Prof. Dr. François Jamar

Department of Nuclear Medicine, Institut de Recherche Expérimentale et Clinique (IREC-MIRO), Cliniques Universitaires Saint-Luc, Université Catholique de Louvain, B-1200 Brussels, Belgium
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2024 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
GAGad Abikhzer
Gad Abikhzer
Giorgio TregliaGiorgio Treglia
Giorgio Treglia
MPMatthieu Pelletier-Galarneau
Matthieu Pelletier-Galarneau
JBJohn Buscombe
John Buscombe
ACArturo Chiti
Arturo Chiti
OGOlivier Gheysens
Olivier Gheysens
Introduction: Hybrid [18F]FDG PET imaging is currently the method of choice for a wide variety of infectious and inflammatory disorders and was recently adopted in several clinical guidelines. A large amount of evidence-based articles, guidelines and appropriate use criteria have been published since the first version of this guideline in 2013. Purpose: To provide updated evidence-based information to assist physicians in recommending, performing and interpreting hybrid [18F]FDG PET examinations for infectious and inflammatory disorders in the adult population. Methods: A systematic literature search of evidence-based articles using whole-body [18F]FDG hybrid imaging on the indications covered within this guideline was performed. All systematic reviews and meta-analyses published within the last 10 years until January 2023 were identified in PubMed/Medline or Cochrane. For each indication covered in this manuscript, diagnostic performance was provided based on meta-analyses or systematic reviews. If not available, results from prospective or retrospective studies were considered based on predefined selection criteria. Results and conclusions: Hybrid [18F]FDG PET is extremely useful in the work-up and management of adults with infectious and inflammatory diseases, as supported by extensive and rapidly growing evidence-based literature and adoption in clinical guidelines. Practical recommendations are provided describing evidence-based indications as well as interpretation criteria and pitfalls. Monitoring treatment response is the most challenging but insufficiently studied potential application in infection and inflammation imaging.


21 October 2017 in Critical Care
Verified
Journal Article
Open access
PDF file
JDJonathan Dugernier
Jonathan Dugernier
SEStephan Ehrmann
Stephan Ehrmann
TSThierry Sottiaux
Thierry Sottiaux
JRJean Roeseler
Jean Roeseler
XWXavier Wittebole
Xavier Wittebole
GRGregory Reychler
Gregory Reychler
This systematic review aimed to assess inhaled drug delivery in mechanically ventilated patients or in animal models. Whole lung and regional deposition and the impact of the ventilator circuit, the artificial airways and the administration technique for aerosol delivery were analyzed. In vivo studies assessing lung deposition during invasive mechanical ventilation were selected based on a systematic search among four databases. Two investigators independently assessed the eligibility and the risk of bias. Twenty-six clinical and ten experimental studies were included. Between 30% and 43% of nominal drug dose was lost to the circuit in ventilated patients. Whole lung deposition of up to 16% and 38% of nominal dose (proportion of drug charged in the device) were reported with nebulizers and metered-dose inhalers, respectively. A penetration index inferior to 1 observed in scintigraphic studies indicated major proximal deposition. However, substantial concentrations of antibiotics were measured in the epithelial lining fluid (887 (406–12,819) μg/mL of amikacin) of infected patients and in sub-pleural specimens (e.g., 197 μg/g of amikacin) dissected from infected piglets, suggesting a significant distal deposition. The administration technique varied among studies and may explain a degree of the variability of deposition that was observed. Lung deposition was lower than 20% of nominal dose delivered with nebulizers and mostly occurred in proximal airways. Further studies are needed to link substantial concentrations of antibiotics in infected pulmonary fluids to pulmonary deposition. The administration technique with nebulizers should be improved in ventilated patients in order to ensure an efficient but safe, feasible and reproducible technique.

22 July 2016 in Annals of Intensive Care
Verified
Journal Article
Open access
PDF file
JDJonathan Dugernier
Jonathan Dugernier
GRGregory Reychler
Gregory Reychler
XWXavier Wittebole
Xavier Wittebole
JRJean Roeseler
Jean Roeseler
VDVirginie Depoortere
Virginie Depoortere
PLPierre-François Laterre
Pierre-François Laterre
Volume-controlled ventilation has been suggested to optimize lung deposition during nebulization although promoting spontaneous ventilation is targeted to avoid ventilator-induced diaphragmatic dysfunction. Comparing topographic aerosol lung deposition during volume-controlled ventilation and spontaneous ventilation in pressure support has never been performed. The aim of this study was to compare lung deposition of a radiolabeled aerosol generated with a vibrating-mesh nebulizer during invasive mechanical ventilation, with two modes: pressure support ventilation and volume-controlled ventilation. Seventeen postoperative neurosurgery patients without pulmonary disease were randomly ventilated in pressure support or volume-controlled ventilation. Diethylenetriaminepentaacetic acid labeled with technetium-99m (2 mCi/3 mL) was administrated using a vibrating-mesh nebulizer (Aerogen Solo®, provided by Aerogen Ltd, Galway, Ireland) connected to the endotracheal tube. Pulmonary and extrapulmonary particles deposition was analyzed using planar scintigraphy. Lung deposition was 10.5 ± 3.0 and 15.1 ± 5.0 % of the nominal dose during pressure support and volume-controlled ventilation, respectively (p < 0.05). Higher endotracheal tube and tracheal deposition was observed during pressure support ventilation (27.4 ± 6.6 vs. 20.7 ± 6.0 %, p < 0.05). A similar penetration index was observed for the right (p = 0.210) and the left lung (p = 0.211) with both ventilation modes. A high intersubject variability of lung deposition was observed with both modes regarding lung doses, aerosol penetration and distribution between the right and the left lung. In the specific conditions of the study, volume-controlled ventilation was associated with higher lung deposition of nebulized particles as compared to pressure support ventilation. The clinical benefit of this effect warrants further studies. Clinical trial registration NCT01879488

21 October 2021 in Cancers
Verified
Journal Article
Open access
PDF file
JDjulien Van Damme
julien Van Damme
BTBertrand TOMBAL
Bertrand TOMBAL
LCLaurence Collette
Laurence Collette
SNSandy Van nieuwenhove
Sandy Van nieuwenhove
Vassiliki PasoglouVassiliki Pasoglou
Vassiliki Pasoglou
FLFrederic Lecouvet
Frederic Lecouvet
Background: Prostate specific membrane antigen (PSMA) positron emission tomography computed tomography (PET-CT) and whole-body magnetic resonance imaging (WB-MRI) outperform standard imaging technology for the detection of metastasis in prostate cancer (PCa). There are few direct comparisons between both modalities. This paper compares the diagnostic accuracy of PSMA PET-CT and WB-MRI for the detection of metastasis in PCa. One hundred thirty-four patients with newly diagnosed PCa (n = 81) or biochemical recurrence after curative treatment (n = 53) with high-risk features prospectively underwent PSMA PET-CT and WB-MRI. The diagnostic accuracy of both techniques for lymph node, skeletal and visceral metastases was compared against a best valuable comparator (BVC). Overall, no significant difference was detected between PSMA PET-CT and WB-MRI to identify metastatic patients when considering lymph nodes, skeletal and visceral metastases together (AUC = 0.96 (0.92–0.99) vs. 0.90 (0.85–0.95); p = 0.09). PSMA PET-CT, however, outperformed WB-MRI in the subgroup of patients with newly diagnosed PCa for the detection of lymph node metastases (AUC = 0.96 (0.92–0.99) vs. 0.86 (0.79–0.92); p = 0.0096). In conclusion, PSMA PET-CT outperforms WB-MRI for the detection of nodal metastases in primary staging of PCa.

1 January 2011 in EJNMMI Research
Verified
Journal Article
Open access
PDF file
SWStephan Walrand
Stephan Walrand
MHMichel Hesse
Michel Hesse
GDGeorges Demonceau
Georges Demonceau
SPStanislas Pauwels
Stanislas Pauwels
FJFrançois Jamar
François Jamar
The purpose of the study is to evaluate whether a pinhole collimator is better adapted to bremsstrahlung single photon emission computed tomography [SPECT] than parallel-hole collimators and in the affirmative, to evaluate whether pinhole bremsstrahlung SPECT, including a simple model of the scatter inside the patient, could provide a fast dosimetry assessment in liver selective internal radiotherapy [SIRT].