The ITER Neutral Beam Test Facility (NBTF), called PRIMA (Padova Research on ITER Megavolt Accelerator), is hosted in Padova, Italy and includes two experiments: MITICA, the full-scale prototype of the ITER heating neutral beam injector, and SPIDER, the full-size radio frequency negative-ions source. The NBTF realization and the exploitation of SPIDER and MITICA have been recognized as necessary to make the future operation of the ITER heating neutral beam injectors efficient and reliable, fundamental to the achievement of thermonuclear-relevant plasma parameters in ITER. This paper reports on design and R&D carried out to construct PRIMA, SPIDER and MITICA, and highlights the huge progress made in just a few years, from the signature of the agreement for the NBTF realization in 2011, up to now-when the buildings and relevant infrastructures have been completed, SPIDER is entering the integrated commissioning phase and the procurements of several MITICA components are at a well advanced stage.
The negative-ion based neutral beam injector for heating and current drive of the ITER plasma (ITER HNB) is under development, at present focusing on the optimization of the full-scale plasma source in the SPIDER test stand. The production of H− or D− ions in the ion source is based on the low work function surfaces obtained by caesium evaporation. This paper describes the caesium conditioning procedure and the corresponding beam performances during the first operation of SPIDER with caesium. Technical solutions to overcome present limitations of the test stand are described. The influence of source parameters on the caesium effectiveness was investigated in short beam pulse operation; with total radio-frequency (RF) power of 400 kW and filling pressure below 0.4 Pa, and a limited number of extraction apertures, a negative ion current density of about 200 A m−2 was extracted in hydrogen, with beam energy lower than 60 keV. Beam optics and beam uniformity were assessed thanks to the acceleration of isolated ion beamlets. A possible procedure to accelerate a uniform beam was demonstrated at low RF power. The results obtained in this first investigation provided key indications on the operation of one of the largest existing sources of accelerated negative hydrogen-like ions.
The ITER heating neutral beam (HNB) injector, based on negative ions accelerated at 1 MV, will be tested and optimized in the SPIDER source and MITICA full injector prototypes, using a set of diagnostics not available on the ITER HNB. The RF source, where the H−/D− production is enhanced by cesium evaporation, will be monitored with thermocouples, electrostatic probes, optical emission spectroscopy, cavity ring down, and laser absorption spectroscopy. The beam is analyzed by cooling water calorimetry, a short pulse instrumented calorimeter, beam emission spectroscopy, visible tomography, and neutron imaging. Design of the diagnostic systems is presented.