A new derivatization high-performance liquid chromatography method with ultraviolet detection was developed and validated for the quantitative analysis of methanesulfonate genotoxic impurities in an innovative drug for the treatment of non-alcoholic fatty liver disease. In this study, sodium dibenzyldithiocarbamate was used as a derivatization reagent for the first time to enhance the sensitivity of the analysis, and NaOH aqueous solution was chosen as a pH regulator to avoid the interference of the drug matrix. Several key experimental parameters of the derivatization reaction were investigated and optimized. In addition, specificity, linearity, precision, stability, and accuracy were validated. The determined results of the samples were consistent with those obtained from the derivatization gas chromatography–mass spectrometry analysis. Thus, the proposed method is a reliable and practical protocol for the determination of trace methanesulfonate genotoxic impurities in drugs containing mesylate groups.
4 August 2023 in Journal of Analytical Methods in Chemistry
Methyl 7,7-dimethoxy-5-(morpholinomethyl)-[4,4-bibenzo[d][1,3] dioxole]-5-carboxylate methanesulfonate (IMM) is an innovative drug for the treatment of nonalcoholic fatty liver disease (NAFLD) owing to its high efficacy and low toxicity. In this study, five minor impurities (I, II, III, IV, and V) were identified and analyzed using spectroscopic evidence, chemical synthetic methods, and liquid chromatography-tandem mass spectrometry (LC-MS/MS). The impurities included hydrolysates and oxidation by-products extracted from both the drug in its final formulation and during synthesis. Toxicity prediction revealed potential carcinogenicity of impurity V containing an N-oxygen fragment. A reliable and selective HPLC method for the quantitative analysis of impurities IIV and a sensitive HPLC-MS/MS method for potential genotoxic impurity V were developed and optimized. The methods were validated based on the International Council for Harmonization guidelines. Satisfactory linearity was obtained for the analytes over the range of 0.12.0μg/mL for impurities IIV and 0.330.0ng/mL for impurity V, and in all cases, the fitting correlation coefficients exceeded 0.999. The obtained limits of detection values were 0.05ng/mL and 0.005μg/mL for impurity V and impurities IIV, respectively. The precision and repeatability of the methods were less than 1.08 and 8.72 for each impurity. The recovery percentages of all impurities were in the range of 91.18111.27, with the relative standard deviation of less than 3.69. The greenness assessment of the HPLC method and the HPLC-MS/MS method were evaluated by using AGREE software with a score value of 0.72 and 0.68, respectively. The recommended procedures that were accurate, specific, and ecofriendly were applied to the existing active pharmaceutical ingredients of IMM, and they generated satisfactory results.
An accurate, rapid, and selective quantitative nuclear magnetic resonance method was developed and validated to assess the purity of IMM-H014, a novel drug for the treatment of metabolic-associated fatty liver disease (MAFLD), and four related substances (impurities I, II, III, and IV). In this study, we obtained spectra of IMM--H014 and related substances in deuterated chloroform using dimethyl terephthalate (DMT) as the internal standard reference. Quantification was performed using the 1H resonance signals at δ 8.13 ppm for DMT and δ 6.5–7.5 ppm for IMM-H014 and its related substances. Several key experimental parameters were investigated and optimized, such as pulse angle and relaxation delay. Methodology validation was conducted based on the International Council for Harmonization guidelines and verified with satisfactory specificity, precision, linearity, accuracy, robustness, and stability. In addition, the calibration results of the samples were consistent with those obtained from the mass balance method. Thus, this research provides a reliable and practical protocol for purity analysis of IMM-H014 and its critical impurities and contributes to subsequent clinical quality control research.