Urban development always has a strong impact on the urban thermal environment, but it is unclear to what extent urbanization factors influence urban heat island intensity (UHII) in mountainous cities, and fewer studies have been conducted on the trends of long-term UHII in mountainous cities. Chongqing, as the only municipality directly under the central government in Southwest China and a typical mountainous city, is chosen as the case study. This study analyzed the interannual and seasonal variations of UHII based on the data from meteorological stations in Chongqing from 1959 to 2018 using the least-squares method and the Mann–Kendall test, and explored the relationship between urbanization factors (urban resident population, gross domestic product (GDP), fixed investments, and gross industrial output value) and UHII. The results show that the increasing rates of temperature in urban areas of Chongqing are significantly higher than those in rural areas affected by urbanization. Using the Mann–Kendall test, it is found that almost all abrupt temperature changes in Chongqing occurred after the rapid urbanization of Chongqing in the 21st century. The annual mean UHII increased from 0.1 °C to 1.5 °C during the study period, with summer making the largest contribution. It is also found that the UHII in Chongqing has increased year by year, especially after the 1980s. The increasing rates of UHII are larger at night and smaller during the day. The increasing trends of nighttime UHII are statistically significant, while those of daytime UHII are not. In addition, UHII and urbanization factors are found to be correlated using the grey relational analysis (GRA). Eventually, a comprehensive UHII index and a comprehensive urbanization index are constructed using principal component analysis (PCA). A tertiary regression model of UHII and urbanization index is established, which reflects that the UHII in Chongqing will continue to grow rapidly with the development of the city.
Certain configurations of liquefied natural gas refueling stations exhibit a deficiency in managing boil-off gas. Furthermore, the ill-conceived linkage between the submersible pump and the gas storage tank pipeline leads to impeded natural gas transmission. This study employs Computational Fluid Dynamics (CFD) methodology to scrutinize the hydrodynamic attributes of T-type tee and dovetail tee configurations implemented in the pipeline design connecting the submersible pump and storage tank in an LNG filling station across diverse operational scenarios. The T-type tee induces detachment of the primary flow from the inner wall due to inertial forces, resulting in vortex formation and heightened resistance, accompanied by increased energy dissipation. Conversely, the dovetail tee, with its circular wall transition, mitigates vortex generation, reducing the separation zone and consequently minimizing resistance and energy loss. The maximum static differential pressure between the inlet and outlet of the dovetail tee is diminished by 52.52% when compared to that of the T-type tee. In the most noteworthy scenarios, the local resistance coefficient of the dovetail tee is even less than 1/10 of that of the T-type tee. In practical engineering applications, the incorporation of dovetail tees leads to a 17.58% reduction in the required elevation difference. This results in a more uniform flow field and enhanced stability in both flow rate and pressure. Such improvements contribute to heightened engineering efficiency and environmental sustainability, particularly evident in the design of LNG filling stations.
Certain configurations of liquefied natural gas refueling stations exhibit a deficiency in managing boil-off gas. Furthermore, the ill-conceived linkage between the submersible pump and the gas storage tank pipeline leads to impeded natural gas transmission. This study employed the computational fluid dynamics (CFD) methodology to scrutinize the hydrodynamic attributes of the T-type tee and dovetail tee configurations implemented in the pipeline design connecting the submersible pump and storage tank in a liquefied natural gas (LNG) filling station across diverse operational scenarios. The T-type tee induces detachment of the primary flow from the inner wall due to inertial forces, which results in vortex formation and heightened resistance, accompanied by increased energy dissipation. The transition of the rounded inner wall of the dovetail tee results in the reduction of eddy current generation and a smaller separation zone, thus minimizing resistance and energy loss. The maximum static differential pressure between the inlet and outlet of the dovetail tee is reduced by 52.52% compared to that of the T-type tee. In practical engineering applications, the use of dovetail tees leads to a reduction in the height difference for the pipeline by 17.58%, resulting in more uniform and stable flow rates and pressures in the flow field. These improvements contribute to engineering efficiency and environmental sustainability and are particularly evident in the design of LNG filling stations.