Rare nucleated CD45 negative cells in peripheral blood may be malignant such as circulating tumor cells. Untouched isolation thereof by depletion of normal is favored yet still technological challenging. We optimized and evaluated a novel magnetic bead-based negative selection approach for enhanced enrichment of rare peripheral blood nucleated CD45 negative cells and investigated the problem of rare cell contamination during phlebotomy. Firstly, the performance of the magnetic cell separation system was assessed using leukocytes and cultivated fibroblast cells in regard to depletion efficiency and the loss of cells of interest. Secondly, a negative selection assay was optimized for high performance, simplicity and cost efficiency. The negative selection assay consisted of; a RBC lysis step, two depletion cycles comprising direct magnetically labelling of leukocytes using anti-CD45 magnetic beads followed by magnetic capture of leukocytes using a duopole permanent magnet. Thirdly, assay evaluation was aligned to conditions of rare cell frequencies and comprised cell spike recovery, cell viability and proliferation, and CD45 negative cell detection. Additionally, the problem of CD45 negative cell contamination during phlebotomy was investigated. The depletion factor and recovery of the negative selection assay measured at most 1600-fold and 96%, respectively, leaving at best 1.5 × 104 leukocytes unseparated and took 35 min. The cell viability was negatively affected by chemical RBC lysis. Proliferation of 100 spiked ovarian cancer cells in culture measured 37% against a positive control. Healthy donor testing revealed findings of nucleated CD45 negative cells ranging from 1 to 22 cells /2.5 × 107 leukocytes or 3.5 mL whole blood in 89% (23/26) of the samples. Our assay facilitates high performance at shortest assay time. The enrichment assay itself causes minor harm to cells and allows proliferation. Our findings suggest that rare cell contamination is unavoidable. An unexpected high variety of CD45 negative cells have been detected. It is hypothesized that a rare cell profile may translate into tumor marker independent screening.
Leptospirosis caused by Leptospira interrogans is the most widespread zoonosis and a major public health problem worldwide. Based on light-scattering and absorption, quantification of leptospires using UV-VIS spectroscopy was used as an indirect counting technique by measuring the optical density and comparing this to automated direct counting using a counting chamber in combination with imaging and analyzing software. Two serovars, Bangkok and Copenhagenii, from log-phase growth were used for the establishment of standard curves. They were found to be linear and slightly different in gradient for each serovar. The ease, rapidity, and reliability of these two adapted and optimized counting techniques may provide a useful alternative enumeration technique for leptospirosis research.
1 October 2018 in Annals of Translational Medicine
Background: Circulating rare cells (CRCs) are benign or malignant minuscule events in the peripheral blood or other bodily fluids. The detection and quantification of certain CRC types is an invaluable or proposed candidate biomarker for diagnosis, prognosis and prediction of various pathological conditions. The list of CRC types and biomarker applicability thereof continues to expand along with improvements in cell selection technology. Past findings may suggest commonness of healthy donor peripheral blood circulating mature erythroblasts. This work suggests the occurrence of morphologically distinct bone marrow native circulating early erythroid precursors that we intend to add to the list of CRCs. Methods: We tested 15 healthy individuals that varied in age and gender employing a negative cell selection assay based on magnetic bead technology to characterize healthy adult circulating CD45 negative cell events using cell surface markers CD71 and glycophorin-A. Results: Positive events were detected and varied in cell and nuclear size ranging between 7.5 µm till 15 µm and 4.5 till 9.2 µm, respectively with distinct appearance under bright field microscope. Cell rarity increased with cell and nuclear size. Largest cells exceeded 13.5 µm in cell diameter and were found in 7 out of 15 donors. Conclusions: Circulating erythroid precursors occur at different stages of maturation and may be part of the benign CRC spectrum.
20 December 2012 in Journal of Physics: Conference Series
We use Wang-Landau sampling with suitable Monte Carlo trial moves to study a hydrophobic-polar (HP) lattice protein confined between two parallel, attractive walls. The density of states is determined iteratively by a random walk in energy space. Thermodynamic and structural properties, such as specific heat, number of surface contacts and number of H-H monomer pairs, are then calculated. When the surface attraction is comparable to the internal attraction among the hydrophobic monomers in the chain, two conformational "transitions", adsorption at higher temperature and collapse at lower temperature, have been analyzed based on these properties. This transition behavior depends on the variation of surface separation.
28 September 2017 in Journal of Biomechanical Engineering
Viewed in renal physiology as a refined filtration device, the glomerulus filters large volumes of blood plasma while keeping proteins within blood circulation. Effects of macromolecule size and macromolecule hydrodynamic interaction with the nanostructure of the cellular layers of the glomerular capillary wall on the glomerular size selectivity are investigated through a mathematical simulation based on an ultrastructural model. The epithelial slit, a planar arrangement of fibers connecting the epithelial podocytes, is represented as a row of parallel cylinders with nonuniform spacing between adjacent fibers. The mean and standard deviation of gap half-width between its fibers are based on values recently reported from electron microscopy. The glomerular basement membrane (GBM) is represented as a fibrous medium containing fibers of two different sizes: the size of type IV collagens and that of glycosaminoglycans (GAGs). The endothelial cell layer is modeled as a layer full of fenestrae that are much larger than solute size and filled with GAGs. The calculated total sieving coefficient agrees well with the sieving coefficients of ficolls obtained from in vivo urinalysis in humans, whereas the computed glomerular hydraulic permeability also falls within the range estimated from human glomerular filtration rate (GFR). Our result indicates that the endothelial cell layer and GBM significantly contribute to solute and fluid restriction of the glomerular barrier, whereas, based on the structure of the epithelial slit obtained from electron microscopy, the contribution of the epithelial slit could be smaller than previously believed.
1 October 2010 in Journal of Mechanical Science and Technology