Summary: The aim was to identify cell and genetic predictors of human blastocyst hatching success in assisted reproduction programmes via a prospective case–control study. Blastocysts, donated by couples in assisted reproduction programmes were used. Hatching success assessment was performed after 144–146 h post-fertilization. The mRNA expression levels of cathepsin V (CTSV), GATA-binding protein 3 (GATA3) and human chorionic gonadotropin beta subunit 3, 5, 7 and 8 (CGB) genes were detected by quantitative real-time polymerase chain reaction. The odds ratio (OR) of hatching due to zona pellucida (ZP) thickness, oocyte and sperm quality, embryo quality and mRNA expression of CTSV, GATA3 and CGB genes in blastocysts was determined. From 62 blastocysts included in the study, 47 (75.8%) were unable to hatch spontaneously. The ZP thickening, and oocyte and sperm quality did not affect human blastocyst ability to hatch, except the combination of cytoplasmic and extracytoplasmic oocyte dysmorphisms (OR = 1.25; 95% confidence interval = 1.08, 1.45). Hatching-capable blastocysts had higher Gardner scale grade and mRNA expression of CTSV, GATA3 and CGB genes than hatching-incapable blastocysts. The human blastocyst hatching success depends on the blastocyst Gardner grade, but not on ZP and gamete quality. Blastocyst development was regulated by CTSV, GATA3 and CGB gene expression.
Coagulopathy in COVID-19 patients is presumably based on systemic hypercoagulation with the inflammatory response. As a result of endothelial dysfunction, tissue factor and von Willebrand factor (vWF) are released into the blood stream, which leads to prothrombinase activation. The vWF/ADAMTS-13 ratio can be used for monitoring the severity of the disease. This observational prospective study included 141 patients with COVID-19. In patients with mild COVID-19 (group 1), the assessment was performed on the 3rd–7th day of illness (point 1) and 14–28 days after recovery (point 2). In patients with moderate (groups 2) and severe (group 3) COVID-19, the assessment was performed during hospitalization (point 1) and after 14 days (point 2). The vWF:RCo/ADAMTS-13:activity (point 1), vWF/ADAMTS-13 (point 2) and vWF:RCo/ADAMTS-13:activity (point 2) ratios were significantly higher in patients with moderate and severe COVID-19. Moreover, in these patients, both ratios increased after recovery (point 2), which is a negative prognostic factor of thrombotic complications. Thus, COVID-19 is characterized by a decrease in the concentration and activity of ADAMTS-13 metalloproteinase, especially in patients with the severe form of COVID-19. A decrease in ADAMTS-13 activity results in an increase in vWF concentration and activity so the ratio of vWF to ADAMTS-13 changes significantly.
Objective: To compare the accuracy of cord blood lactate measurement using gas analyzer and portable devices in order to assess possibility of implementation of these devices in clinical practice.Methods: We performed a prospective observational study using 30 umbilical cord samples which were obtained immediately after birth. Portable electrochemical devices Lactate Scout (SensLab GmbH, Leipzig, Germany) and StatStrip Lactate (NOVA Biomedical, Waltham, MA, USA) were used to determine lactate level. A gas analyzer ABL800 FLEX (Radiometer Medical ApS, Brønshøj-Husum, Denmark) was used as a reference. Base excess (BE), pH, partial oxygen (pO2) and carbon dioxide (pCO2) pressure, hemoglobin (ctHb) and bilirubin (ctBl) levels were measured.Results: The mean umbilical cord blood lactate level determined by the gas analyzer was 5.85 ± 2.66 mmol/L (ranging from 1.4 mmol/L to 13.4 mmol/L). Lactate level estimated by Lactate Scout was 5.66 ± 2.65 mmol/L and did not significantly differ from the reference method level (P = 0.2547). The mean lactate level determined by StatStrip Lactate was significantly lower than by the gas analyzer – 4.81 ± 2.38 mmol/L (P < 0.0001). Umbilical cord blood pH, BE, pO2and pCO2, ctHb and ctBl levels did not affect the accuracy of the lactate measurement in absolute units (mmol/L).Conclusion: Umbilical cord blood lactate level measured by StatStrip Lactate was lower than estimated by the ABL800 FLEX gas analyzer. This shows the necessity to develop decision-making reference points separately for each device. Umbilical cord blood pH, BE, pO2and pCO2, ctHb and ctBl levels did not affect the accuracy of measurements by electrochemical portable devices.
20 August 2018 in Bulletin of Experimental Biology and Medicine