Hidekazu Takano

Dr. Hidekazu Takano

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2006 in Japanese Journal of Applied Physics
Verified
Journal Article
Closed access
TKTakahisa Koyama
Takahisa Koyama
TTTakuya Tsuji
Takuya Tsuji
KYKeisuke Yoshida
Keisuke Yoshida
HTHidekazu Takano
Hidekazu Takano
YTYoshiyuki Tsusaka
Yoshiyuki Tsusaka
YKYasushi Kagoshima
Yasushi Kagoshima

10 February 2020 in Quantum Beam Science
Verified
Journal Article
Open access
PDF file
AMAtsushi Momose
Atsushi Momose
HTHidekazu Takano
Hidekazu Takano
YWYanlin Wu
Yanlin Wu
KHKoh Hashimoto
Koh Hashimoto
TSTetsuo Samoto
Tetsuo Samoto
TSTakenao Shinohara
Takenao Shinohara
Under the JST-ERATO project in progress to develop X-ray and neutron phase-imaging methods together, recent achievements have been selected and reviewed after describing the merit and the principle of the phase imaging method. For X-ray phase imaging, recent developments of four-dimensional phase tomography and phase microscopy at SPring-8, Japan are mainly presented. For neutron phase imaging, an approach in combination with the time-of-flight method developed at J-PARC, Japan is described with the description of new Gd grating fabrication.

1 December 2020 in Journal of Bone and Mineral Research
Verified
Journal Article
Open access
PDF file
YKYukiko Kuroda
Yukiko Kuroda
KKKatsuhiro Kawaai
Katsuhiro Kawaai
NHNaoya Hatano
Naoya Hatano
YWYanlin Wu
Yanlin Wu
HTHidekazu Takano
Hidekazu Takano
KMK. Matsuo
K. Matsuo
Auditory ossicles in the middle ear and bony labyrinth of the inner ear are highly mineralized in adult mammals. Cellular mechanisms underlying formation of dense bone during development are unknown. Here, we found that osteoblast‐like cells synthesizing highly mineralized hearing‐related bones produce both type I and type II collagens as the bone matrix, while conventional osteoblasts and chondrocytes primarily produce type I and type II collagens, respectively. Furthermore, these osteoblast‐like cells were not labeled in a “conventional osteoblast”‐specific green fluorescent protein (GFP) mouse line. Type II collagen‐producing osteoblast‐like cells were not chondrocytes as they express osteocalcin, localize along alizarin‐labeled osteoid, and form osteocyte lacunae and canaliculi, as do conventional osteoblasts. Auditory ossicles and the bony labyrinth exhibit not only higher bone matrix mineralization but also a higher degree of apatite orientation than do long bones. Therefore, we conclude that these type II collagen‐producing hypermineralizing osteoblasts (termed here auditory osteoblasts) represent a new osteoblast subtype. © 2021 The Authors. Journal of Bone and Mineral Research published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research (ASBMR).

15 December 2022 in Physics Reports
Verified
Journal Article
Open access
ASAnton P.J. Stampfl
Anton P.J. Stampfl
ZLZhongdong Liu
Zhongdong Liu
JHJun Hu
Jun Hu
KSKei Sawada
Kei Sawada
HTHidekazu Takano
Hidekazu Takano
GMGiorgio Margaritondo
Giorgio Margaritondo

5 August 2019 in Optica
Verified
Journal Article
Closed access
HTHidekazu Takano
Hidekazu Takano
KHKoh Hashimoto
Koh Hashimoto
YNYukinori Nagatani
Yukinori Nagatani
JIJeff Irwin
Jeff Irwin
LOLars Omlor
Lars Omlor
AMAtsushi Momose
Atsushi Momose

6 August 2018 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
HTHidekazu Takano
Hidekazu Takano
YWYanlin Wu
Yanlin Wu
JIJeff Irwin
Jeff Irwin
SMStan Maderych
Stan Maderych
MLMarty Leibowitz
Marty Leibowitz
AMAtsushi Momose
Atsushi Momose
A grating interferometer (GI) system has been installed in an X-ray microscope equipped with a Zernike phase contrast (ZPC) system and a Cu rotating anode X-ray source. The GI and ZPC systems are switchable, and their performances of phase information extraction have been compared. The GI system is based on a Lau interferometer consisting of an absorption grating and a π/2 phase grating, which extracts a magnified phase shift map of a sample via a phase-stepping measurement. The ZPC system generates a phase contrast image by using a phase plate and a corresponding condenser device. The ZPC system and the GI system are compared in terms of detectability of phase objects. By the Fourier analysis of images of a logarithmic ruler pattern, the spatial resolution was found to be identical between the two systems. Although the sensitivity depends on the sample size, the signal-to-noise ratio of polystyrene spheres with a few microns in diameter was used for sensitivity comparison, showing the superior sensitivity of the GI system to that of the ZPC system. The quantitativeness of the GI system with the phase-stepping measurement was also demonstrated over the ZPC system, which generates halo and shade-off artifacts. The GI system exhibits twin image artifacts that need to be resolved for practical applications of the technique.