Chaowei Zhuang

Dr. Chaowei Zhuang

Tsinghua University, Beijing, China
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 March 2021 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
CZChaowei Zhuang
Chaowei Zhuang
JCJiangbei Cao
Jiangbei Cao
RZRujin Zhang
Rujin Zhang
GXGuihua Xiao
Guihua Xiao
JHJing Hu
Jing Hu
QDQionghai Dai
Qionghai Dai
Interactions between the cerebral cortex and the deep cerebellar nuclei play important roles in cognitive processes. However, conventional microscopes fail to dynamically record cellular structures in distinct brain regions and at different depths, which requires high resolution, large field of view (FOV), and depth of field (DOF). Here we propose a single-photon excited fluorescence microscopy technique that performs simultaneous cortex and hippocampus imaging, enabled by a customized microscope and a chronic optical window. After we implant a glass microwindow above the hippocampus, the surface of the hippocampus is shifted to the superficial plane. We demonstrate that the proposed technique is able to image cellular structures and blood vessel dynamics in the cortex and the hippocampus in in vivo experiments, and is compatible with various mesoscopic systems.

26 July 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
RZRujin Zhang
Rujin Zhang
CZChaowei Zhuang
Chaowei Zhuang
ZWZilin Wang
Zilin Wang
GXGuihua Xiao
Guihua Xiao
KCKunsha Chen
Kunsha Chen
JCJiangbei Cao
Jiangbei Cao
The fluorescence microscope has been widely used to explore dynamic processes in vivo in mouse brains, with advantages of a large field-of-view and high spatiotemporal resolution. However, owing to background light and tissue scattering, the single-photon wide-field microscope fails to record dynamic neural activities in the deep brain. To achieve simultaneous imaging of deep-brain regions and the superficial cortex, we combined the extended-field-of-view microscopy previously proposed with a novel prism-based cranial window to provide a longitudinal view. As well as a right-angle microprism for imaging above 1 mm, we also designed a new rectangular-trapezoidal microprism cranial window to extend the depth of observation to 1.5 mm and to reduce brain injury. We validated our method with structural imaging of microglia cells in the superficial cortex and deep-brain regions. We also recorded neuronal activity from the mouse brains in awake and anesthesitized states. The results highlight the great potential of our methods for simultaneous dynamic imaging in the superficial and deep layers of mouse brains.

15 May 2024 in Biomedicine & Pharmacotherapy
Verified
Journal Article
Open access
ZWZilin Wang
Zilin Wang
KCKunsha Chen
Kunsha Chen
XWXiaodong Wu
Xiaodong Wu
PZPengchang Zheng
Pengchang Zheng
ALAo Li
Ao Li
JCJiangbei Cao
Jiangbei Cao
Anesthesia inhibits neural activity in the brain, causing patients to lose consciousness and sensation during the surgery. Layers 2/3 of the cortex are important structures for the integration of information and consciousness, which are closely related to normal cognitive function. However, the dynamics of the large-scale population of neurons across multiple regions in layer 2/3 during anesthesia and recovery processes remains unclear. We conducted simultaneous observations and analysis of large-scale calcium signaling dynamics across multiple cortical regions within cortical layer 2/3 during isoflurane anesthesia and recovery in vivo by high-resolution wide-field microscopy. Under isoflurane-induced anesthesia, there is an overall decrease in neuronal activity across multiple regions in the cortical layer 2/3. Notably, some neurons display a paradoxical increase in activity during anesthesia. Additionally, the activity among multiple cortical regions under anesthesia was homogeneous. It is only during the recovery phase that variability emerges in the extent of increased neural activity across different cortical regions. Within the same duration of anesthesia, neural activity did not return to preanesthetic levels. To sum up, anesthesia as a dynamic alteration of brain functional networks, encompassing shifts in patterns of neural activity, homogeneousness among cortical neurons and regions, and changes in functional connectivity. Recovery from anesthesia does not entail a reversal of these effects within the same timeframe.

17 December 2020 in Frontiers in Chemistry
Verified
Journal Article
Open access
CZChaowei Zhuang
Chaowei Zhuang
XLXinyang Li
Xinyang Li
YZYuanlong Zhang
Yuanlong Zhang
LKLingjie Kong
Lingjie Kong
Hao XieHao Xie
Hao Xie
QDQionghai Dai
Qionghai Dai
Compared with two-photon point-scanning microscopy, two-photon temporal focusing microscopy (2pTFM) provides a parallel high-speed imaging strategy with optical sectioning capability. Owing to out-of-focus fluorescence induced by scattering, 2pTFM suffers deteriorated signal-to-background ratio (SBR) for deep imaging in turbid tissue, Here, we utilized the photobleaching property of fluorophore to eliminate out-of-focus fluorescence. According to different decay rates in different focal depth, we extract the in-focus signals out of backgrounds through time-lapse images. We analyzed the theoretical foundations of photobleaching imprinting of the line-scanning temporal focusing microscopy, simulated implementation for background rejection, and demonstrated the contrast enhancement in MCF-10A human mammary epithelial cells and cleared Thy1-YFP mouse brains. More than 50% of total background light rejection was achieved, providing higher SBR images of the MCF-10A samples and mouse brains. The photobleaching imprinting method can be easily adapted to other fluorescence dyes or proteins, which may have application in studies involving relatively large and nontransparent organisms.