Goshu Kenea

Mr. Goshu Kenea


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2022 in International Journal of Analytical Chemistry
Verified
Journal Article
Open access
PDF file
TLTofik Gali Aba Lulesa
Tofik Gali Aba Lulesa
DBDejene Beyene
Dejene Beyene
MEMillion Ebba
Million Ebba
GKGoshu Kenea
Goshu Kenea
Water treatment is the primary consideration before utilizing water for different purposes. Surface water is highly vulnerable to pollution, either due to natural or anthropogenic processes. The main targets of this study were to investigate surface water treatment using Moringa Oleifera (MO), the electrocoagulation process (EC), and the Moringa Oleifera assisted electrocoagulation process (MOAEC). The Moringa Oleifera, EC process, and Moringa Oleifera-assisted EC process are effective mechanisms for the removal of COD (Chemical Oxygen Demand), BOD (Biological Oxygen Demand), TDS (Total Dissolved Solids), phosphate, TSS (Total Suspended Solids), and color from surface water. Different operating parameters such as pH (511), the dosage of coagulant (0.20.5g), contact time or reaction time (2050 minutes), current (0.20.5A), and settling time (520 minutes) were considered. The maximum removal efficiency using Moringa Oleifera and the EC process was COD (85.48), BOD (78.50), TDS (84.5), phosphate (95.70), TSS (93.90), color (94.50), and COD (90.50), BOD (87), TDS (97.50), phosphate (89.10), TSS (95.80), and color (96.15), respectively. Similarly, with the application of MOAEC, 91.47, 89.35, 97.0, 90.20, 9.10, and 95.70 of COD, BOD, TDS, phosphate, TSS, and color were removed, respectively. The EC process and MOAEC were more effective in the removal of COD, BOD, TDS, TSS, and color than using MO. More phosphate was removed using MO than the EC process and MOAEC. Additionally, the effects of different operating parameters were studied on the removal efficiency.

24 May 2022 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
MTMuliye Tarekegn
Muliye Tarekegn
Kabtamu Getachew HailuKabtamu Getachew Hailu
Kabtamu Getachew Hailu
GKGoshu Kenea
Goshu Kenea
Concrete is the most extensively utilized construction material globally and is increasingly used due to industrialization and urbanization. Currently, most scientists worldwide are concentrating their attention on effective strategies to adopt materials from large amounts of waste resources as a partial substitute for cement in concrete production due to scarcity of resources and continuous environmental pollution. In this study, an experimental investigation was conducted on the properties of concrete made from the partial replacement of cement by hybrid coffee husk ash (CHA) and sugarcane bagasse ash (SCBA). The study considered different percentages (0%, 5%, 10%, and 15%) of hybrid ash to assess the engineering properties of fresh and hardened concrete of C-20/25. A slump and compaction factor test was conducted to study the workability of fresh concrete. The study showed that, as the percentage of replacement increased from 0% to 15%, the workability of the concrete decreased up to 15.15%. In addition, compression, split tensile, and flexural tests were done on the 7th, 14th, and 28th days to investigate the properties of hardened concrete. Based on the test result, 10% of hybrid ash was the maximum percentage of replacement that showed a compressive and tensile strength greater than the target strength. Therefore, the study concludes that up to 10% replacement of cement by hybrid ash may be employed in concrete production, which in turn is used to minimize the cost of construction and environmental pollution by recycling waste coffee husk and sugarcane bagasse.

1 January 2022 in Advances in Civil Engineering
Verified
Journal Article
Open access
PDF file
AFAlemu Feyissa
Alemu Feyissa
GKGoshu Kenea
Goshu Kenea
The composite construction strategies realize an increasing number of sizeable applications in regions like bridges, ramps, homes, and different exceptional places. The component of composite structure considered in the study contains composite slab, profiled steel sheeting, steel beam, shear connector, and reinforcement cages. The investigation mainly focused on the structural performance of demountable shear connectors in composite slabs and steel beams with profiled steel sheeting. An extensive nonlinear finite element model was used to carry out in FE software Abaqus 6.14. Nonlinear behavior of concrete, stud connector, profiled steel sheeting, reinforcement cage, and steel beam are included in the finite element model. In this study, 24 specimens were taken into consideration to investigate the capacity of the shear connection, the load‐slip curve of stud, failures modes of demountable shear connectors, and concrete crushing in the composite floor with profiled steel sheeting. The analysis confirmed that as the diameter of the shear connector increased from 19 to 22 mm, the capacity of the shear connector also increased by 54.313% and 28.903% in both open through and reentrant profiled steel sheeting, respectively. In addition, as the height of the profiled steel sheeting increased from 50 to 64 mm, the capacity of the shear connector is increased by 11.601% and 32.564% in open through and reentrant profiled steel sheeting, respectively. Similarly, when the concrete grade increased from C‐40 to C‐60, the capacity of the shear connector also increased by 70.128% and 48.301% with open and reentrant profiled steel sheeting, respectively. Furthermore, sensitivity analysis is done to see how much each input parameters affect the output parameter.

27 April 2022 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
EMEdosa Megarsa
Edosa Megarsa
GKGoshu Kenea
Goshu Kenea
This study presents an extensive analytical investigation of the shear performance of reinforced concrete beams by using ferrocement composite as transverse reinforcement. Nonlinear finite element simulation was conducted in Abaqus 6.14 software package. Fifteen beam models were selected under two-point loading. The main parameters considered includes the diameter, spacing, number of layers of wire mesh, and its combination with stirrups. The results testified that as the diameter and number of layers of wire mesh increased, the ultimate failure load, shear capacity, and stiffness of the model specimen also increased. However, as the number of layers becomes greater than three, no significant change happens in the shear performance of the beam. In another way, the failure load, shear capacity, and stiffness of the beam models are decreased, as the spacing between wire mesh is increased. Furthermore, the study confirmed that under the same weight criteria, the shear performance of RC beam specimens with wire mesh and its combination with stirrups as shear reinforcement is greater than specimens with stirrups only. Finally, the sensitivity analysis is conducted in MS excel to access the effect of each independent variable on the ultimate failure load of the RC beam.

1 January 2022 in Advances in Civil Engineering
Verified
Journal Article
Open access
PDF file
AHAman Hamicha
Aman Hamicha
GKGoshu Kenea
Goshu Kenea
Finite element modeling is becoming widely applicable for the assessment of structural behavior, which is accurate and reliable, since conducting the full experimental test is time‐consuming and very expensive. Previously conducted research confirmed that there is a good agreement with the experimental tests. In this study, a nonlinear finite element analysis with the ABAQUS software package has been taken to investigate the response of reinforced concrete exterior shear wall‐slab connection subjected to cyclic loading. The structural responses such as load‐carrying capacity, energy dissipation, ductility, and stiffness degradation have been studied. Connection type, an aspect ratio of the thickness of the slab to the thickness of the shear wall (ts/tw), the aspect ratio of the height of the shear wall to the effective width of the slab (H/We), and concrete strength were used as study parameters to evaluate their effect on the structural response of the connection. A total of sixteen models have been selected based on the parametric study and objective of the study. The results show that the exterior shear wall‐slab connection with U‐type connection has high load‐carrying capacity than the other connection types. As the aspect ratios of ts/tw, H/We and concrete strength increase, the ultimate load capacity and energy dissipation capacity increase. In other words, as the number of loading cycles increases, the stiffness of the connection is decreased.

1 January 2022 in Advances in Civil Engineering
Verified
Journal Article
Open access
PDF file
GKGoshu Kenea
Goshu Kenea
AFAlemu Feyissa
Alemu Feyissa
Nonlinear finite element (FE) simulation was employed to look into the behavior of flat slab‐column connections exposed to lateral cyclic loading. The study focused on the effect of drop panel and concrete grade by taking into consideration the element size sensitivity on the response of the joint. The study considered twelve specimens for the investigation. Four concrete grades having a magnitude of 47.7, 60, 75, and 90 MPa were selected. Three element sizes of 30 mm, 40 mm, and 60 mm were undertaken to access the mesh size sensitivity of the outputs. Six specimens are with drop panels, and others are without drop panels. The concrete‐damaged plasticity model has been used to model the specimens. Reduced eight noded bricks (C3D8R) and two noded trusses (T3D2) elements have been used for modeling concrete and steel, respectively. Cracking pattern, slab vertical deflection, strain distribution, ductility, load‐drift ratio, cracking load capacity, yielding load capacity, and ultimate load capacity are the main outputs of the FE simulation. The study confirmed a considerable increase in load‐carrying capacity and a decrease in ductility as the concrete grade increased. In another way, the load‐carrying capacity and ductility were slightly increased and decreased, respectively, as the slab‐column connection is provided with a drop panel. As element size decreases, the result obtained becomes more realistic.