Lara K. F. Schorn

Dr. Lara K. F. Schorn

Department of Oral & Maxillofacial Surgery, University of Duesseldorf, Moorenstr 5, D-40225 Dusseldorf, Germany
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 June 2017 in Head & Face Medicine
Verified
Journal Article
Open access
PDF file
Lara K. F. SchornLara K. F. Schorn
Lara K. F. Schorn
CSChristoph Sproll
Christoph Sproll
Michelle Alicia OmmerbornMichelle Alicia Ommerborn
Michelle Alicia Ommerborn
CNChristian Naujoks
Christian Naujoks
NKNorbert R. Kübler
Norbert R. Kübler
RDRita Depprich
Rita Depprich
Sufficient vertical and lateral bone supply and a competent osteogenic healing process are prerequisities for the successful osseointegration of dental implants in the alveolar bone. Several techniques including autologous bone grafts and guided bone regeneration are applied to improve quality and quantity of bone at the implantation site. Depending on the amount of lacking bone one- or two-stage procedures are required. Vertical bone augmentation has proven to be a challenge particularly in terms of bone volume stability. This study focuses on the three dimensional vertical bone generation in a one stage procedure in vivo. Therefore, a collagenous disc-shaped scaffold (ICBM = Insoluble Collagenous Bone Matrix) containing rhBMP-2 (Bone Morphogenetic Protein-2) and/or VEGF (Vascular Endothelial Growth Factor) was applied around the coronal part of a dental implant during insertion. RhBMP-2 and VEGF released directly at the implantation site were assumed to induce the generation of new vertical bone around the implant. One hundred eight titanium implants were inserted into the mandible and the tibia of 12 mini pigs. Four experimental groups were formed: Control group, ICBM, ICBM + BMP-2, and ICBM + BMP-2 + VEGF. After 1, 4 and 12 weeks the animals were sacrificed and bone generation was investigated histologically and histomorphometrically. After 12 weeks the combination of ICBM + rhBMP2 + VEGF showed significantly more bone volume density (BVD%), a higher vertical bone gain (VBG) and more vertical bone gain around the implant (PVBG) in comparison to the control group. By using collagenous disc-shaped matrices in combination with rhBMP-2 and VEGF vertical bone can be generated in a one stage procedure without donor site morbidity. The results of the presenting study suggest that the combination of rhBMP-2 and VEGF applied locally by using a collagenous carrier improves vertical bone generation in vivo. Further research is needed to establish whether this technique is applicable in clinical routines.

9 March 2022 in Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Open access
JLJulian Lommen
Julian Lommen
Lara K. F. SchornLara K. F. Schorn
Lara K. F. Schorn
CSChristoph Sproll
Christoph Sproll
JHJan Haussmann
Jan Haussmann
NKNorbert R. Kübler
Norbert R. Kübler
Bálint TamaskovicsBálint Tamaskovics
Bálint Tamaskovics
Surgical reconstruction after segmental mandibulectomy in patients with oral cancer commonly requires implantation of titanium plates, which cause metallic artifacts in CT examinations detrimental for image quality. Therefore, the aim of the present study was to evaluate CT artifacts and image quality of the polymer plate materials polyetheretherketone (PEEK), polyetherketoneketone (PEKK), polyphenylsulfone (PPSU), and polyethylene (PE) in mandible reconstruction. Five plates (titanium, PEEK, PEKK, PPSU, and PE) were successively surgically inserted in a human cadaveric specimen using eight (1) titanium and (2) zirconium oxide screws. Streak and blooming artifacts were assessed in 1 mm CT scans with and without metallic artifact reduction algorithms (MAR) in this cross-sectional study. The different plate materials were analyzed for their effect on Hounsfield unit (HU) values resulting in streak artifacts. Blooming artifacts were measured as virtual growth of plates compared to actual size. Subjective image quality was assessed by 3 independent observers. Statistics were conducted by multifactorial ANOVA and Bonferroni's post hoc test. Titanium (182.42 HU; SD ± 3.09) was associated with significantly more streak and blooming artifacts compared to the polymers PEEK (86.41 HU; SD ± 1.72; P < .001), PEKK (85.50 HU; SD ± 2.75; P < .001), PPSU (85.51 HU; SD ± 1.97; P < .001), and PE (85.52 HU; SD ± 3.33; P < .001) implants. No significant differences could be seen between the screw types (titanium vs zirconium oxide) (P = .75) or the activation or inactivation of MAR (P = .85). Image quality was best for PE and worst for titanium implants in combination with zirconium oxide screws. Polymers plate materials PEEK, PEKK, PPSU, and PE significantly reduce CT artifacts and improve image quality facilitating the radiological interpretation of implant surrounding tissues. This effect is beneficial for radiological tumor follow-up and CT-based planning of adjuvant radiotherapy.

1 March 2021 in Head & Face Medicine
Verified
Journal Article
Open access
PDF file
JLJulian Lommen
Julian Lommen
Lara K. F. SchornLara K. F. Schorn
Lara K. F. Schorn
BRBenjamin Roth
Benjamin Roth
CNChristian Naujoks
Christian Naujoks
JHJörg Handschel
Jörg Handschel
CSChristoph Sproll
Christoph Sproll
Background: Gland preserving techniques in the treatment of sialolithiasis have continuously replaced radical surgery. The aim of this study was to evaluate a multimodal treatment algorithm in the therapy of sialolithiasis and assess improvement of HRQoL perceived by patients. Methods: Patients with sialolithiasis were treated by a multimodal treatment algorithm based on multiplicity of stones, stone size, affected gland, and stone position. The therapeutic spectrum ranged from conservative measures, extracorporeal shockwave lithotripsy, interventional sialendoscopy, combined endoscopic-surgical procedures to surgical gland removal as ultima ratio. Outcomes were evaluated by surgeons by means of the electronic patient record and by patients themselves using a standardized questionnaire. Results: 87 patients treated for sialolithiasis were comprised in this study. The submandibular gland (SMG) was affected in 58.6% and the parotid gland (PG) in 41.4% of cases. Mean patient age was 41.67 years for SMG and 48.91 years for PG. In over 80% of cases sialolithiasis was associated with classic meal-related pain and swelling. Type and intensity of symptomatic sialolithiasis were not dependent on patient age or gender, nor could a relation between the affected gland and the occurrence of symptoms be demonstrated. Overall, 86.2% of cases were reported as cured using the multimodal step-by-step treatment algorithm. Resection of the affected gland could be dispensed in 98.9% of cases. According to patients pain could be reduced in 94.3% of cases. Conclusions: The analyzed treatment algorithm of increasing invasiveness is a favorable and effective tool to successfully treat sialolithiasis in > 86% of cases. For the first time, the present study shows that patient-perceived improvement of HRQoL due to ease of symptoms has an even higher success rate of > 94%.

Verified
Journal Article
Open access
DSDaman D. Singh
Daman D. Singh
Lara K. F. SchornLara K. F. Schorn
Lara K. F. Schorn
ESE. Bradley Strong
E. Bradley Strong
MGMichael Grant
Michael Grant
ASAlexander Schramm
Alexander Schramm
MRMajeed Rana
Majeed Rana
Study Design: This study presents a case-control study of 33 patients who underwent secondary orbital reconstruction, evaluating techniques and outcome. Objective: Adequate functional and aesthetical appearance are main goals for secondary orbital reconstruction. Insufficient premorbid orbital reconstruction can result in hypoglobus, enophthalmos, and diplopia. Computer-assisted surgery and the use of patient-specific implants (PSIs) is widely described in the literature. The authors evaluate the use of selective laser-melted PSIs and hypothesize that PSIs are an excellent option for secondary orbital reconstruction. Methods: The sample was composed of 33 patients, previously treated with primary orbital reconstruction, presenting themselves with indications for secondary reconstruction (i.e. enophthalmos, diplopia, or limited eye motility). Computed tomography and/or cone beam data sets were assessed before and after secondary reconstruction comparing intraorbital volumes, infraorbital angles, and clinical symptoms. Clinical outcomes were assessed using a standardized protocol. Results: Results show a significant change in intraorbital volumes and a reduction of clinical symptoms after secondary reconstruction. Conclusions: Outcomes of this study suggest that secondary orbital reconstruction can be performed routinely using selective laser-melted PSIs and titanium spacers.

30 March 2020 in Oral Radiology
Verified
Journal Article
Open access
PDF file
JNJulia Nitschke
Julia Nitschke
Lara K. F. SchornLara K. F. Schorn
Lara K. F. Schorn
HHHenrik Holtmann
Henrik Holtmann
UZUwe Zeller
Uwe Zeller
JHJörg Handschel
Jörg Handschel
JLJulian Lommen
Julian Lommen
Objectives: The aim of this study was to determine whether a handheld (HH) X-ray device (Nomad Pro 2) is capable of producing equivalent or even superior X-ray image quality in comparison to a wall-mounted (WM) dental X-ray unit (Heliodent Plus) on the basis of objectifiable image quality parameters. Methods: Anatomical, radiological and biological dental X-ray image quality parameters of a handheld dental X-ray device (Nomad Pro 2, Kavo Kerr, Biberach, Germany) were compared to a standard wall-mounted dental X-ray unit (Heliodent Plus, Sirona Dental Systems, Bensheim, Germany) using a maxillofacial phantom. In addition, the effect of different operators (dentists, dental students, dental assistants) on the dental X-ray image quality was measured. Results: HH and WM devices showed comparable image quality for anterior teeth, premolars, molars and bitewing images. During the two-month investigational period, the radiation exposure level for the operator of the Nomad Pro 2 was 0.1 mSv for 203 images. Dentists as the highest trained personnel enrolled in the study achieved better image quality with the Nomad Pro 2 as compared to dental students and dental assistants, especially in the molar region. Conclusions: A HH device delivers a comparable image quality to a WM device. In addition, there seem to be short learning curves with regard to image acquisition when using a handheld device, which is further minimised by the previous training of the operating personnel. HH dental X-ray devices, such as the Nomad Pro 2 are a promising adjunct for dental radiology in cases where WM units are of limited practicability.

Verified
Journal Article
Open access
PDF file
Majeed RanaMajeed Rana
Majeed Rana
HMHenriette Louise Möllmann
Henriette Louise Möllmann
Lara K. F. SchornLara K. F. Schorn
Lara K. F. Schorn
JLJulian Lommen
Julian Lommen
MRMadiha Rana
Madiha Rana
KHKarsten Hufendiek
Karsten Hufendiek
Contemporary advances in technology have allowed the transfer of knowledge from industrial laser melting systems to surgery; such an approach could increase the degree of accuracy in orbital restoration. The aim of this study was to examine the accuracy of selective laser melted PSIs (patient-specific implants) and navigation in primary orbital reconstruction. Ninety-six patients with orbital fractures were included in this study. Planned vs. achieved orbital volumes (a) and angles (b) were compared to the unaffected side (n = 96). The analysis included the overlay of post-treatment on planned images (iPlan 3.0.5, Brainlab®, Feldkirchen, Germany). The mean difference in orbital volume between the digitally planned orbit and the postoperative orbit was 29.16 cm3 (SD 3.54, presurgical) to 28.33 cm3 (SD 3.64, postsurgical, t = 5.00, df = 95.00; p < 0.001), resulting in a mean volume difference (planned vs. postop) of less than 1 cm3. A 3D analysis of the color mapping showed minor deviations compared to the mirrored unaffected side. The results suggested that primary reconstruction in complex orbital wall fractures can be routinely achieved with a high degree of accuracy by using selective laser melted orbital PSIs.