The overall duration of acquiring a Nyquist sampled 3D dataset can be significantly shortened by enhancing the efficiency of ${k}$ -space sampling. This can be achieved by increasing the coverage of ${k}$ -space for every trajectory interleave. Furthermore, acceleration is possible by making use of advantageous undersampling properties. In this paper, a versatile 3D center-out ${k}$ -space trajectory based on Jacobian elliptic functions (Seiffert’s spiral) is presented. The trajectory leads to a low-discrepancy coverage of ${k}$ -space using a considerably reduced number of readouts compared with other approaches. Such a coverage is achieved for any number of interleaves, and, therefore, even single-shot trajectories can be constructed to be combined with, for example, hyperpolarized media. Furthermore, acceleration is achievable due to non-coherent undersampling properties of the trajectory in combination with non-linear reconstruction techniques like compressed sensing (CS). Simulations of point-spread functions and discrepancy evaluations compare Seiffert’s spiral to the established 3D cones approach. Imaging capabilities are evaluated by comparison of in vivo knee images using Nyquist and undersampled datasets in combination with CS reconstructions.
Cardiovascular magnetic resonance (CMR) imaging has become an accurate and versatile imaging modality to visualize the cardiovascular system in normal or abnormal conditions. In preclinical research, small rodent animal models of human cardiovascular diseases are frequently used to investigate the basic underlying mechanism of normal and abnormal cardiac function and for monitoring the disease progression under therapy. Technical improvements have enabled the transfer of CMR to small animal research, and as such made this non-invasive technique available to provide insights into cardiac morphology, function, perfusion, and pathophysiology in small animal cardiac disease models. This article reviews the basic technical approaches to in vivo small animal magnetic resonance imaging and its variants for the most promising applications.
Cardiovascular magnetic resonance imaging has proven valuable for the assessment of structural and functional cardiac abnormalities. Even although it is an established imaging method in small animals, the long acquisition times of gated or self‐gated techniques still limit its widespread application. In this study, the application of tiny golden angle radial sparse MRI (tyGRASP) for real‐time cardiac imaging was tested in 12 constitutive nexilin (Nexn) knock‐out (KO) mice, both heterozygous (Het, N = 6) and wild‐type (WT, N = 6), and the resulting functional parameters were compared with a well‐established self‐gating approach. Real‐time images were reconstructed for different temporal resolutions of between 16.8 and 79.8 ms per image. The suggested approach was additionally tested for dobutamine stress and qualitative first‐pass perfusion imaging. Measurements were repeated twice within 2 weeks for reproducibility assessment. In direct comparison with the high‐quality, self‐gated technique, the real‐time approach did not show any significant differences in global function parameters for acquisition times below 50 ms (rest) and 31.5 ms (stress). Compared with WT, the end‐diastolic volume (EDV) and end‐systolic volume (ESV) were markedly higher (P < 0.05) and the ejection fraction (EF) was significantly lower in the Het Nexn‐KO mice at rest (P < 0.001). For the stress investigation, a clear decrease of EDV and ESV, and an increase in EF, but maintained stroke volume, could be observed in both groups. Combined with ECG‐triggering, tyGRASP provided first‐pass perfusion data with a temporal resolution of one image per heartbeat, allowing the quantitative assessment of upslope curves in the blood‐pool and myocardium. Excellent inter‐study reproducibility was achieved in all the functional parameters. The tyGRASP is a valuable real‐time MRI technique for mice, which significantly reduces the scan time in preclinical cardiac functional imaging, providing sufficient image quality for deriving accurate functional parameters, and has the potential to investigate real‐time and beat‐to‐beat changes.
Purpose: To adapt the non-uniform Self-Gating (nuSG) method and compare it to established self-gating approaches for lung imaging in uniform and highly irregular respiratory patterns.Methods: Six healthy volunteers underwent free breathing lung MRI using a radial tiny golden angle ultrashort echo-time sequence. Acquisitions were performed with the volunteer breathing as uniformly as possible and with a deliberately non-uniform respiratory pattern. The acquired data was reconstructed with the nuSG method, previously introduced for cardiac imaging and imaging of the temporomandibular joint (TMJ) and compared to established k-space based and image-based self-gating approaches. Residual motion blur, SNR and functional values were assessed and compared to reference breath-hold acquisitions.Results: nuSG is capable of reconstructing high-quality images for uniform and non-uniform breathing patterns and is furthermore capable of resolving motion in cases where additional motion is superimposed or no clear motion surrogate exists. Derived functional values do not differ significantly from other image-based gated reconstructions - and in the case of non-uniform respiratory patterns replicate the reference BH values.Conclusion: Image based approaches are computationally more demanding but yield better results in all aspects. In scenarios with a direct surrogate for respiratory motion (i.e. the lung-liver interface) the extraction of a one-dimensional navigator is sufficient. When there is no direct surrogate for the motion of the target structure available (e.g., considerable through-plane motion or a different source of motion), the two-dimensional correlation-based measure used in nuSG is able to track the motion more accurately.
(1) Background: Segmented Cartesian Cardiovascular magnetic resonance (CMR) often fails to deliver robust assessment of cardiac function in patients with arrhythmia. We aimed to assess the performance of a tiny golden-angle spiral real-time CMR sequence at 1.5 T for left-ventricular (LV) volumetry in patients with irregular heart rhythm; (2) Methods: We validated the real-time sequence against the standard breath-hold segmented Cartesian sequence in 32 patients, of whom 11 presented with arrhythmia. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) were assessed. In arrhythmic patients, real-time and standard Cartesian acquisitions were compared against a reference echocardiographic modality; (3) Results: In patients with sinus rhythm, good agreements and correlations were found between the segmented and real-time methods, with only minor, non-significant underestimation of EDV for the real-time sequence (135.95 ± 30 mL vs. 137.15 ± 31, p = 0.164). In patients with arrhythmia, spiral real-time CMR yielded superior image quality to the conventional segmented imaging, allowing for excellent agreement with the reference echocardiographic volumetry. In contrast, in this cohort, standard Cartesian CMR showed significant underestimation of LV-ESV (106.72 ± 63.51 mL vs. 125.47 ± 72.41 mL, p = 0.026) and overestimation of LVEF (42.96 ± 10.81% vs. 39.02 ± 11.72%, p = 0.039); (4) Conclusions: Real-time spiral CMR improves image quality in arrhythmic patients, allowing reliable assessment of LV volumetry.
23 January 2024 in Computerized Medical Imaging and Graphics
Left atrial appendage (LAA) is the source of thrombi formation in more than 90% of strokes in patients with nonvalvular atrial fibrillation. Catheter-based LAA occlusion is being increasingly applied as a treatment strategy to prevent stroke. Anatomical complexity of LAA makes percutaneous occlusion commonly performed under transesophageal echocardiography (TEE) and X-ray (XR) guidance especially challenging. Image fusion techniques integrating 3D anatomical models derived from pre-procedural imaging into the live XR fluoroscopy can be applied to guide each step of the LAA closure. Cardiac magnetic resonance (CMR) imaging gains in importance for radiation-free evaluation of cardiac morphology as alternative to gold-standard TEE or computed tomography angiography (CTA). Manual delineation of cardiac structures from non-contrast enhanced CMR is, however, labor-intensive, tedious, and challenging due to the rather low contrast. Additionally, arrhythmia often impairs the image quality in ECG synchronized acquisitions causing blurring and motion artifacts. Thus, for cardiac segmentation in arrhythmic patients, there is a strong need for an automated image segmentation method. Deep learning-based methods have shown great promise in medical image analysis achieving superior performance in various imaging modalities and different clinical applications. Fully-convolutional neural networks (CNNs), especially U-Net, have become the method of choice for cardiac segmentation. In this paper, we propose an approach for automatic segmentation of cardiac structures from non-contrast enhanced CMR images of arrhythmic patients based on CNNs implemented in a multi-stage pipeline. Two-stage implementation allows subdividing the task into localization of the relevant cardiac structures and segmentation of these structures from the cropped sub-regions obtained from previous step leading to efficient and effective way of automated cardiac segmentation.