The delivery of healthcare from a distance, also known as telemedicine, has evolved over the past 50 years, changing the way healthcare is delivered globally. Its integration into numerous domains has permitted high-quality care that transcends the obstacles of geographic distance, lack of access to health care providers, and cost. Ultrasound is an effective diagnostic tool and its application within telemedicine has advanced substantially in recent years, particularly in high-income settings and low-resource areas. The literature in Pubmed from 1960–2020 was assessed with the keywords “ultrasound”, “telemedicine”, “ultrasound remote”, and “tele-ultrasound” to conduct a SWOT analysis (strengths, weaknesses, opportunities, and threats). In addressing strengths and opportunities, we emphasized practical aspects, such as the usefulness of tele-ultrasound and the cost efficiency of it. Furthermore, aspects of medical education in tele-ultrasound were considered. When it came to weaknesses and threats, we focused on issues that may not be solved immediately, and that require careful consideration or further development, such as new software that is not yet available commercially.
OGon behalf of the Extracorporeal Multi-Organ Repair Study Group
on behalf of the Extracorporeal Multi-Organ Repair Study Group
+15
Background: Survival following cardiac arrest (CA) remains poor after conventional cardiopulmonary resuscitation (CCPR) (6–26%), and the outcomes after extracorporeal cardiopulmonary resuscitation (ECPR) are often inconsistent. Poor survival is a consequence of CA, low-flow states during CCPR, multi-organ injury, insufficient monitoring, and delayed treatment of the causative condition. We developed a new strategy to address these issues. Methods: This all-comers, multicenter, prospective observational study (69 patients with in- and out-of-hospital CA (IHCA and OHCA) after prolonged refractory CCPR) focused on extracorporeal cardiopulmonary support, comprehensive monitoring, multi-organ repair, and the potential for out-of-hospital cannulation and treatment. Result: The overall survival rate at hospital discharge was 42.0%, and a favorable neurological outcome (CPC 1+2) at 90 days was achieved for 79.3% of survivors (CPC 1+2 survival 33%). IHCA survival was very favorable (51.7%), as was CPC 1+2 survival at 90 days (41%). Survival of OHCA patients was 35% and CPC 1+2 survival at 90 days was 28%. The subgroup of OHCA patients with pre-hospital cannulation showed a superior survival rate of 57.1%. Conclusions: This new strategy focusing on repairing damage to multiple organs appears to improve outcomes after CA, and these findings should provide a sound basis for further research in this area.
Survival and neurological outcomes after out-of-hospital cardiac arrest (OHCA) remain low. The further development of prehospital extracorporeal resuscitation (ECPR) towards Controlled Automated Reperfusion of the Whole Body (CARL) has the potential to improve survival and outcome in these patients. In CARL therapy, pulsatile, high blood-flow reperfusion is performed combined with several modified reperfusion parameters and adjusted defibrillation strategies. We aimed to investigate whether pulsatile, high-flow reperfusion is feasible in refractory OHCA and whether the CARL approach improves heart-rhythm control during ECPR. In a reality-based porcine model of refractory OHCA, 20 pigs underwent prehospital CARL or conventional ECPR. Significantly higher pulsatile blood-flow proved to be feasible, and critical hypotension was consistently prevented via CARL. In the CARL group, spontaneous rhythm conversions were observed using a modified priming solution. Applying potassium-induced secondary cardioplegia proved to be a safe and effective method for sustained rhythm conversion. Moreover, significantly fewer defibrillation attempts were needed, and cardiac arrhythmias were reduced during reperfusion via CARL. Prehospital CARL therapy thus not only proved to be feasible after prolonged OHCA, but it turned out to be superior to conventional ECPR regarding rhythm control.
Background: Hands-on training in point-of-care ultrasound (POC-US) should ideally comprise bedside teaching, as well as simulated clinical scenarios. High-fidelity phantoms and portable ultrasound simulation systems are commercially available, however, at considerable costs. This limits their suitability for medical schools. A Linux-based software for Emergency Department Ultrasound Simulation (edus2TM) was developed by Kulyk and Olszynski in 2011. Its feasibility for POC-US education has been well-documented, and shows good acceptance. An important limitation to an even more widespread use of edus2, however, may be due to the need for a virtual machine for WINDOWS® systems. Our aim was to adapt the original software toward an HTML-based solution, thus making it affordable and applicable in any simulation setting. Methods: We created an HTML browser-based ultrasound simulation application, which reads the input of different sensors, triggering an ultrasound video to be displayed on a respective device. RFID tags, NFC tags, and QR Codes™ have been integrated into training phantoms or were attached to standardized patients. The RFID antenna was hidden in a mock ultrasound probe. The application is independent from the respective device. Results: Our application was used successfully with different trigger/scanner combinations and mounted readily into simulated training scenarios. The application runs independently from operating systems or electronic devices. Conclusion: This low-cost, browser-based ultrasound simulator is easy-to-build, very adaptive, and independent from operating systems. It has the potential to facilitate POC-US training throughout the world, especially in resource-limited areas.
Background: Regarding the overall inadequate results after cardiopulmonary resuscitation, the development of new treatment concepts is urgently needed. Controlled Automated Reperfusion of the whoLe body (CARL) represents a therapy bundle to control the conditions of reperfusion and the composition of the reperfusate after cardiac arrest (CA). The aim of this study was to investigate the plasma expander’s role in the CARL priming solution and examine its mechanism of action. Methods: Viscosity, osmolality, colloid osmotic pressure (COP), pH and calcium binding of different priming solutions were measured in vitro and compared to in vivo data. N = 16 pigs were allocated to receive CARL following 20 min of untreated CA with either human albumin 20% (HA, N = 8) or gelatin polysuccinate 4% (GP, N = 8). Blood gas analyses were performed during the first hour of reperfusion and catecholamine and fluid requirements were recorded. Neurological outcome was assessed by neurological deficit scoring (NDS) on the seventh day. Results: In vitro, addition of HA to the CARL priming solution resulted in higher COP and higher calcium-binding than GP. In vivo, treatment with HA led to greater reduction of ionized calcium and higher extracorporeal flows within the first 30 min of reperfusion with no difference in catecholamine support and fluid requirement. Seven-day survival of 75% with no difference in NDS was observed in both groups. Conclusions: Our data show that the plasma expander in the CARL priming solution has a significant effect on the initial reperfusate and can potentially influence the course of resuscitation. However, seven-day survival and NDS did not differ between groups.
The latest guidelines for cardiopulmonary resuscitation recommend that in case of suspected cardiac arrest first responders, who are close to the emergency location, should be notified by a smartphone app or text message. Smartphone Alerting Systems (SAS) aim to reduce the resuscitation-free interval. Thus, there is a need for uniform reporting of process times. Objective: To compare the response times in a SAS either by using global positioning system (GPS) data or by manual confirmation of first responders arriving at the scene. Methods: In the region of Freiburg (Southern Germany, 1,531 km2, 493,000 inhabitants), a SAS is activated when the emergency dispatch centre receives a call regarding suspected cardiac arrest. First responders who accept a mission are tracked using GPS. GPS-based times are logged for each responder when their position is within a radius of 100, 50, or 10 metres around the geographical position of the reported emergency. When arriving at the patient location, the first responders manually confirm “arrived” via their app. GPS-based and manually confirmed response arrival times were compared for all cases between 1 October and 31 March. Results: 192 missions with correct manual logging of the arrival time were included. GPS-based times were available in 175 (91%), 100 (52%), and 30 (16%) cases within radii of 100, 50, and 10 metres, respectively. GPS arrival times were approximately 1.5 minutes shorter when using a 100-metre radius and significantly longer when using a 10-metre radius. No difference was found for a 50-metre radius, but this would result in a lack of data in nearly half of the cases. Conclusion: GPS-based logging of arrival times leads to missing data. A 100-metre circle is associated with a low number of missing values, but 1.5 minutes must be added for the last 100 metres the first responder has to move. A wide range of the difference in response times (GPS vs. manual confirmation) must be regarded as a disadvantage. Manual confirmation reveals precise response times, but first responders may forget to confirm when they arrive. Trial registration: DRKS00016625 (14-April-2019)