Livia Nagy

Dr. Livia Nagy


Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2006 in Journal of Biochemical and Biophysical Methods
Verified
Journal Article
Closed access
LNLivia Nagy
Livia Nagy
GGGergely Gyetvai
Gergely Gyetvai
LKLászló Kollár
László Kollár
GNGéza Nagy
Géza Nagy

1 June 2001 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
LNLivia Nagy
Livia Nagy
GNGéza Nagy
Géza Nagy
PHPéter Hajós
Péter Hajós

1 May 2003 in Talanta
Verified
Journal Article
Closed access
ÖSÖ. Szabadka
Ö. Szabadka
EVE. Varga
E. Varga
LNLivia Nagy
Livia Nagy

27 March 2022 in Molecules
Verified
Journal Article
Open access
PDF file
DFDániel Filotás
Dániel Filotás
JPJavier Izquierdo Pérez
Javier Izquierdo Pérez
BFBibiana María Fernández-Pérez
Bibiana María Fernández-Pérez
LNLivia Nagy
Livia Nagy
GNGéza Nagy
Géza Nagy
Ricardo SoutoRicardo Souto
Ricardo Souto
Spatially resolved information on corrosion reactions operating at the cut edges of coated metals can be obtained using microelectrochemical scanning techniques using a suitable selection of operation modes and scanning probes. The scanning vibrating electrode technique (SVET) provides current density maps with a spatial resolution of the order of the dimensions of the sample, which allows the temporal evolution of the corrosion reactions to be followed over time. This leads to the identification and localization of cathodic and anodic sites, although the technique lacks chemical specificity for the unequivocal identification of the reactive species. The application of scanning electrochemical microscopy (SECM) was previously limited to image cathodic reaction sites, either due to oxygen consumption in the amperometric operation or by the alkalinisation of the electrolyte in potentiometric operation. However, it is shown that anodic sites can be effectively monitored using an ion-selective microelectrode (ISME) as a probe. The ISME probes detected differences in the local concentrations of Zn2+ and OH− ions from the cut edges of a complete coil coating system compared to the same system after the polymeric layers were removed. In this way, it has been shown that the inhibitor loading in the polymer layers effectively contributes to reducing the corrosion rates at the cut edge, thus helping to extend the useful life of the sacrificial galvanized layer bonded directly to the steel matrix. Additionally, these two probe configurations can be integrated into a multi-electrode tip for potentiometric operation to simultaneously monitor localized changes in pH values and metal ion dissolution in a single scan. Spatial and temporal distributions were further investigated using different rastering procedures, and the potential of constructing pseudomaps for 2D-imaging is described.

1 January 2014 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
ZŐZsuzsanna Őri
Zsuzsanna Őri
AKAndrás Kiss
András Kiss
ACAnton Ciucu
Anton Ciucu
CMConstantin Mihailciuc
Constantin Mihailciuc
CSCristian Dragos Stefanescu
Cristian Dragos Stefanescu
GNGeza Nagy
Geza Nagy

18 September 2019 in European Journal of Inorganic Chemistry
Verified
Journal Article
Closed access
PDF file
SKSoma J. Keszei
Soma J. Keszei
SBSzabolcs Balogh
Szabolcs Balogh
CFCsaba Fehér
Csaba Fehér
LNLivia Nagy
Livia Nagy
NTNikolay Tumanov
Nikolay Tumanov
RSRita Skoda-Földes
Rita Skoda-Földes