Tea Gegenava

Dr. Tea Gegenava


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2021 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
KHKensuke Hirasawa
Kensuke Hirasawa
JKJurrien H Kuneman
Jurrien H Kuneman
GSGurpreet K Singh
Gurpreet K Singh
TGTea Gegenava
Tea Gegenava
DHDavid Hautemann
David Hautemann
VDVictoria Delgado
Victoria Delgado
Peak left atrial longitudinal strain (PALS) is a marker of the left atrial (LA) reservoir function. Novel feature tracking (FT) software allows assessment of LA strain from multidetector computed tomography (MDCT) data. This study aimed at evaluating the agreement between speckle tracking echocardiography (STE) and FT MDCT for the measurement of PALS in patients with sinus rhythm (SR) and with atrial fibrillation (AF). The current study included 318 patients (80 ± 7 years, 54% male) with dynamic MDCT data acquired prior to transcatheter aortic valve implantation. PALS was measured by transthoracic echocardiography using STE (PALSecho) and MDCT using dedicated FT software (PALSCT). In the overall population, the median values of PALSecho and PALSCT were 19.0 [interquartile range (IQR) 12.0–25.0] % and 15.3 (IQR 9.2–19.7) %, respectively. High correlation between PALSecho and PALSCT was observed (r = 0.789, P < 0.001) with a mean bias of −3.7%. The correlation between PALSecho and PALSCT was better among patients with SR (N = 258; r = 0.704, P < 0.001) as compared to patients with AF (N = 60; r = 0.622, P < 0.001). PALSecho and PALSCT showed a good agreement in patients with severe aortic stenosis (AS) regardless of the cardiac rhythm. FT MDCT may be an important adjuvant modality for assessing LA reservoir function in patients with severe AS.

12 August 2022 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
KHKensuke (Ken) Hirasawa
Kensuke (Ken) Hirasawa
GSGurpreet K Singh
Gurpreet K Singh
JKJurrien H Kuneman
Jurrien H Kuneman
TGTea Gegenava
Tea Gegenava
FKFrank van der Kley
Frank van der Kley
VDVictoria Delgado
Victoria Delgado
Aortic stenosis (AS) induces left atrial (LA) remodelling through the increase of left ventricular (LV) filling pressures. Peak LA longitudinal strain (PALS), reflecting LA reservoir function, has been proposed as a prognostic marker in patients with AS. Feature-tracking (FT) multi-detector computed tomography (MDCT) allows assessment of LA strain from MDCT data. The aim of this study is to investigate the association between PALS using FT MDCT and survival in patients with severe AS who underwent transcatheter aortic valve implantation (TAVI). A total of 376 patients (mean age 80 ± 7 years, 53% male) who underwent MDCT before TAVI and had suitable data for assessment of PALS using dedicated FT software, were included. The patients were classified into four groups according to PALS quartiles; PALS > 19.3% (Q1, highest reservoir function), 15.0–19.3% (Q2), 9.1–14.9% (Q3), and ≤9.0% (Q4, lowest reservoir function). The primary outcome was all-cause mortality. During a median of 45 (22–68) months follow-up, 148 patients (39%) died. On multivariable Cox regression analysis, PALS was independently associated with all-cause mortality [hazard ratio (HR): 1.044, 95% confidence interval (CI): 1.012–1.076, P = 0.006]. Compared with patients in Q1, patients in Q3 and Q4 were associated with higher risk of mortality after TAVI [HR: 2.262 (95% CI: 1.335–3.832), P = 0.002 for Q3, HR: 3.116 (95% CI: 1.864–5.210), P < 0.001 for Q4]. PALS assessed with FT MDCT is independently associated with all-cause mortality after TAVI. Feature-tracking computed tomography assessment of left atrial reservoir strain in patients with severe aortic stenosis treated with transcatheter aortic valve implantation.

8 February 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
KHKensuke Hirasawa
Kensuke Hirasawa
NVN.M. Vo
N.M. Vo
TGTea Gegenava
Tea Gegenava
SPStephan Milhorini Pio
Stephan Milhorini Pio
SWSuzanne E. van Wijngaarden
Suzanne E. van Wijngaarden
VDVictoria Delgado
Victoria Delgado
The aim of this study is to evaluate the agreement between three-dimensional (3D) transesophageal echocardiography (TEE) and multidetector computed tomography (MDCT) for assessing mitral annular (MA) dimensions. A total of 105 patients (79 ± 9 years old, 52% male) who underwent clinically indicated 3D TEE and MDCT feasible for MA geometrical assessment were included. Using dedicated semi-automated postprocessing software, MA geometry, including mitral annular area (MAA), perimeter, septal-lateral (SL) diameter, and inter-trigonal (TT) diameter, was evaluated using 3D TEE and MDCT. Compared to 3D TEE, MAA, perimeter, and SL distance measured on MDCT data were larger (9.9 ± 3.0 vs. 9.3 ± 3.1 cm2 for MAA; 115 ± 18 vs. 108 ± 18 mm for perimeter; and 35 ± 5 vs. 32 ± 5 cm for SL distance, all p < 0.001). By contrast, the TT distance was comparable between MDCT and 3D TEE (26 ± 4 vs. 26 ± 4 cm, p = 0.258). The correlations of all the MA dimensions were good to excellent between the two modalities (R = 0.911 for MAA, 0.890 for perimeter, 0.739 for TT distance, and 0.857 for SL distance, respectively, all p < 0.001). This study showed good agreement between 3D TEE- and MDCT-derived MA measurements although MDCT systematically provided larger MAA, perimeter, and SL distance compared with 3D TEE.

1 January 2019 in JACC: Cardiovascular Imaging
Verified
Journal Article
Closed access
TGTea Gegenava
Tea Gegenava
EVE. Mara Vollema
E. Mara Vollema
RARachid Abou
Rachid Abou
LGLaurien Goedemans
Laurien Goedemans
ARAlexander van Rosendael
Alexander van Rosendael
VDVictoria Delgado
Victoria Delgado

10 November 2023 in RMD Open
Verified
Journal Article
Open access
PDF file
TGTea Gegenava
Tea Gegenava
FFFederico Fortuni
Federico Fortuni
NLNina Marijn van Leeuwen
Nina Marijn van Leeuwen
ATAnders H Tennoe
Anders H Tennoe
AHAnna-Maria Hoffmann-Vold
Anna-Maria Hoffmann-Vold
Nina Ajmone MarsanNina Ajmone Marsan
Nina Ajmone Marsan
Background: Cardiovascular involvement is one of the leading causes of mortality in systemic sclerosis (SSc) and is reported to be higher in men as compared with women. However, the cause of this difference is largely unknown. The objective of this study was to assess sex differences in echocardiographic characteristics, including left ventricular global longitudinal strain (LV GLS), as a potential explanation of sex differences in outcomes. Methods: A total of 746 patients with SSc from four centres, including 628 (84%, 54±13 years) women and 118 (16%, 55±15 years) men, were evaluated with standard and advanced echocardiographic examinations. The independent association of the echocardiographic parameters with the combined endpoint of cardiovascular events-hospitalisation/death was evaluated. Results: Men and women with SSc showed significant differences in disease characteristics and cardiac function. After adjusting for the most important clinical characteristics, while LV ejection fraction and diastolic function were not significantly different anymore, men still presented with more impaired LV GLS as compared with women (−19% (IQR −20% to −17%) vs −21% (IQR: −22% to −19%), p<0.001). After a median follow-up of 48 months (IQR: 26–80), the combined endpoint occurred in 182 patients. Men with SSc experienced higher cumulative rates of cardiovascular events-hospitalisation/mortality (χ2=8.648; Log-rank=0.003), and sex differences were maintained after adjusting for clinical confounders, but neutralised when matching the groups for LV GLS. Conclusion: In patients with SSc, male sex is associated with worse cardiovascular outcomes even after adjusting for important clinical characteristics. LV GLS was more impaired in men as compared with women and potentially explains the sex difference in cardiovascular outcomes.