Shuiyuan He

Dr. Shuiyuan He

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2022 in Energies
Verified
Journal Article
Open access
PDF file
JRJiahui Ren
Jiahui Ren
WLWenli Lin
Wenli Lin
XLXinbo Liu
Xinbo Liu
SHShuiyuan He
Shuiyuan He
ZDZhonghao Dongye
Zhonghao Dongye
LDLijun Diao
Lijun Diao
With greater power density, a hybrid power source that combines supercapacitors and batteries has a wide range of applications in pulse-operated power systems. In this paper, a supercapacitor/battery semi-active hybrid energy storage system (HESS) with a full current-type control strategy is presented. The studied HESS is composed of batteries, supercapacitors, and a bidirectional buck–boost converter. The converter is controlled such that supercapacitors supply load power pulses, and batteries provide the power in steady state. To realize the fast compensation of the supercapacitors to the load power pulses, a power distribution module based on hysteresis control theory is designed in the control system. Moreover, the control strategy does not require the model parameters of the converter and supercapacitors, so the control system is simplified. A complete configuration scheme and cost analysis of the proposed HESS are also presented. Obtained results show that the proposed supercapacitor/battery semi-active HESS has good performance in terms of dynamic response, weight, and energy utilization coefficient (EUC).

5 September 2022 in IEEE Access
Verified
Journal Article
Open access
CKChengwei Kang
Chengwei Kang
HPHongliang Pan
Hongliang Pan
SHShuiyuan He
Shuiyuan He
JRJiahui Ren
Jiahui Ren
PCPeicheng Cong
Peicheng Cong
LDLijun Diao
Lijun Diao
To improve the lightweight level of auxiliary converters for urban rail vehicles, full SiC intermediate frequency auxiliary converters have become a trend. Aiming at its core component, a full SiC intermediate frequency isolated DC-DC converter using Boost + LLC topology is studied in this paper. The working principle and characteristics of the converter are analyzed in detail. Based on the operating characteristics of the LLC resonant converter and the realization mechanism of soft switching, an optimization design method of the resonant parameters is proposed, which can make LLC resonant converters exhibit the characteristics of DC transformers and realize soft switching in the full load range. Considering the power losses of the converter and the voltage stress of SiC MOSFET, the intermediate bus voltage design method is given. Finally, the correctness of the parameter design method is verified by simulation and experiment, and the performance of the full SiC intermediate frequency isolated DC-DC converter is analyzed. When the input voltage is 1500V and the output power is 15kW, the efficiency of the converter reaches 96.21%. Compared with the Si intermediate frequency isolated DC-DC converter, the power density is improved by 80.62%.

24 February 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
XLXinbo Liu
Xinbo Liu
SHShuiyuan He
Shuiyuan He
RMRuiqi Ma
Ruiqi Ma
CKChengwei Kang
Chengwei Kang
YMYingtao Ma
Yingtao Ma
LDLijun Diao
Lijun Diao
This paper proposes a resonant parameter design method for high-frequency power LLC DCX converter, aiming to achieve ZVS under high power conditions and improve the overall performance of the converter. Firstly, a detailed derivation process of the electrical parameters design is presented, and an LLC converter dead time state model is established. The analytical formulation encompassing dead time and resonant parameters combine the influence of junction capacitances and high-frequency resonance during dead time. Through manipulation of the phase angle of the high-frequency resonant current within the dead time, a comprehensive assessment of the ZVS is conducted. This assessment takes into account variations in power level and phase angles. This analysis realizes the matched phase angles and electrical parameters to achieve ZVS. Moreover, this study focusing on resonant capacitor incorporating withstand voltage and voltage gain, and resonant inductor addressing matched parameter and stability. Thus, the method proposed improves accuracy and safety, assisting the design of parameters. Finally, a 30-kHz 2×50-kW prototype is constructed and validated through experiments to confirm the suggested methodology, where the efficiency of the prototype at full load is 99.06%.

30 December 2024 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
XLXinbo Liu
Xinbo Liu
SHShuiyuan He
Shuiyuan He
RMRuiqi Ma
Ruiqi Ma
SYShibin Yang
Shibin Yang
YXYuhang Xi
Yuhang Xi
LDLijun Diao
Lijun Diao
This article proposes a systematic method to analyze the resonant parameters, considering the common-mode voltage (CMV) and power density in full-bridge (FB) LLC-DC transformer (DCX) converters. A time-domain model of the CMV source triggered by high-frequency resonance is derived, and its frequency spectrum is obtained through Fourier decomposition. Furthermore, this study assesses the impact of resonant and parasitic parameters on CMV. In addition, for the selection of appropriate resonant parameters, two boundaries and their intersection are formulated. These boundaries encompass the consideration of CMV reduction and the maintenance of gain stability and resonant capacitor voltage. The importance of these proper resonant parameters is verified by a $2 \times 50$ kW prototype with 950-V input and 630-V output. Experiments show that with the proper resonant parameters, the LLC-DCX converter achieves CMV reduction in the high-frequency range. It provides the attenuation of up to 12.77 and 26.02 dB in the 0.15–0.5-MHz and 0.5–30-MHz frequency bands, respectively, when operating under rated conditions. Comparative analysis of the resonant element’s volume reveals an enhancement in power density.

21 March 2025 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
XLXinbo Liu
Xinbo Liu
LDLijun Diao
Lijun Diao
HLHaodong Li
Haodong Li
CKChengwei Kang
Chengwei Kang
RMRuiqi Ma
Ruiqi Ma
ZLZezheng Li
Zezheng Li
This article investigates the impact of SiC MOSFET module’s drive and parasitic parameters on common-mode voltage (CMV). A time-domain model of the switching noise source is derived, considering drive and parasitic parameters, and its frequency spectrum is obtained through the Fourier transform. The propagation path of CM noise based on a double-pulse test circuit is, furthermore, analyzed. Second, an ANSYS/Simplorer-based simulation test platform is established to evaluate the comprehensive sensitivity analysis of the impact of various parameters on electrical stress, loss, and CMV. Based on this, this article proposes a multiobjective optimization algorithm where the simulation solution is used as the initial solution set. The optimization of the parameters with high comprehensive sensitivity is performed using a multiobjective genetic optimization algorithm, and the optimal design was selected from the Pareto front generated by Nondominated Sorting Genetic Algorithm (NSGA-II). The importance of these proper drive parameters is verified by a 1500 V/150 kW Boost converter. The results show that the optimized selected drive parameters operating at rated conditions, provide attenuation of up to 5.2 dB in the 0.15–30 MHz frequency bands, and reduce the voltage stress and the current stress by 33.8 V and 31 A.

7 April 2026 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
SHShuiyuan He
Shuiyuan He
RMRuiqi Ma
Ruiqi Ma
CXChongshan Xie
Chongshan Xie
YGYunhao Guo
Yunhao Guo
JZJiepin Zhang
Jiepin Zhang
LDLijun Diao
Lijun Diao
In high-voltage high-power rail transit auxiliary power supply (APS) systems, ensuring zero-voltage switching (ZVS) under discontinuous conduction mode (DCM) is critical for LLC resonant converters (LLC RCs). However, the temperature sensitivity of the turn-off transient in high-voltage field-stop insulated gate bipolar transistors (FS IGBTs) is often neglected, posing a risk of ZVS failure under thermal stress. In response to this challenge, this article proposes a temperature dependent analytical model and an optimal design method. Specifically, an analytical model is derived to capture the characteristic two-stage dVCE/dt of FS IGBTs during the near zero-current turn-off (near-ZCT) transient. Based on this model, a parameter design methodology for LLC RCs is developed, incorporating constraints on junction temperature and turn-off current. Unlike conventional approaches, the proposed method optimizes dead-time selection to ensure ZVS and DCM operation across the full operating temperature range. The approach is validated on a 150-kW prototype, achieving a peak efficiency of 98.97% at full load.