Yu chen Qian

Dr. Yu chen Qian


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YQYu chen Qian
Yu chen Qian
YXYong Xie
Yong Xie
JJJia Jianjun
Jia Jianjun
LZLiang Zhang
Liang Zhang
In this study, an active microvibration isolation system is developed for precision space payload. Vibrational environment affects the performance and reliability of measuring instruments. To improve the measurement accuracy of the precision space payload, an active vibration isolation system based on eight vibration isolation modules, which are applied for microvibration isolation on the satellite, is designed. A vibration suppression control strategy for multiple degrees of freedom is studied. A hybrid control method involving a feedback and a feedforward controller based on a nonlinear tracking differentiator and an nth-order weak integrator, respectively, was adopted to optimize the suppression effect of microvibration. As a result, the microvibration of the order of mg can be reduced to the order of μg through the active control of modules. Research experiment results show that the root cumulative power spectral density of the systemic sensitive frequency band in the range of 0.5–200 Hz, i.e., microvibration frequency band in the optical reference cavity, has been reduced to in the order of μg in three directions, which satisfied the requirements of aerospace engineering.

28 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
YQYu chen Qian
Yu chen Qian
YXYong Xie
Yong Xie
JJJia Jianjun
Jia Jianjun
LZLiang Zhang
Liang Zhang
The optical reference cavity in an ultrastable laser is sensitive to vibrations; the microvibrations in a space platform affect the accuracy and stability of such lasers. In this study, an active vibration isolation controller is proposed to reduce the effect of vibrations on variations in the cavity length and improve the frequency stability of ultrastable lasers. Based on the decentralized control strategy, we designed a state-differential feedback controller with a linear quadratic regulator (LQR) and added a disturbance observer (DOB) to estimate the source noise. Experiments were conducted using an active vibration isolation system; the results verified the feasibility and performance of the designed controller. The accelerations along the axis (Z-, X-, Y-) directions were suppressed in the low-frequency band within 200 Hz, and the root-cumulative power spectral densities (PSDs) declined to 1.17 × 10−5, 7.16 × 10−6, and 8.76 × 10−6 g. This comprehensive vibration met the requirements of an ultrastable laser.