Jiří Plášek

Dr. Jiří Plášek


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2021 in The American Journal of the Medical Sciences
Verified
Journal Article
Closed access
JPJiří Plášek
Jiří Plášek
JGJ. Gumulec
J. Gumulec
JMJ. Máca
J. Máca
JŠJ. Škarda
J. Škarda
VPV. Procházka
V. Procházka
JVJan Václavík
Jan Václavík

23 September 2019 in Biomedical Papers
Verified
Journal Article
Open access
PDF file
MHMiroslav Homza
Miroslav Homza
OMOndrej Machaczka
Ondrej Machaczka
MPMartin Porzer
Martin Porzer
MKMilan Kozak
Milan Kozak
JPJiří Plášek
Jiří Plášek
DSDavid Sipula
David Sipula
Ankle brachial index (ABI) is the principal screening method for peripheral arterial disease (PAD). In this study, we compare various types of Doppler-derived and oscillometric ABIs with results obtained through duplex ultrasonography. 62 patients were enrolled in the study. For each limb, blood pressures for both ankle arteries and the arm were measured using Doppler and an automated oscillometric device. Duplex ultrasound was performed for all limbs and occlusions >50% were considered PAD-positive. ABI was calculated using both higher (HABP) and lower (LABP) arterial blood pressure on the individual limbs and the ability to predict duplex-detected stenoses was evaluated. LABP calculation provided results superior to the guideline-recommended HABP. Considering patients with ABI >1.4 or measurement failure as PAD-positive further enhanced the test parameters. The higher ABI cut-off of 1.0 resulted in somewhat better sensitivities (max 92%) and negative predictive values (max 87%) at the expense of a substantial increase in the number of false positives. Oscillometric method yielded poor sensitivities but very good specificities (max 94%) and positive predictive values (max 90%). Doppler-based LABP provides better results than the guideline-recommended HABP in diabetic patients, nevertheless even this method is not perfect. Increasing the cut-off value to 1.0 in these patients does not bring a substantial improvement of the test performance. Patients with high ABI should be automatically considered PAD-positive and referred for further investigation using imaging techniques.

20 April 2026 in European Heart Journal
Verified
Journal Article
Open access
LPL H G van der Pol
L H G van der Pol
Bartłomiej TomasikBartłomiej Tomasik
Bartłomiej Tomasik
WHWiert F Hoeksema
Wiert F Hoeksema
SMStefano Mandija
Stefano Mandija
MMMarcin Miszczyk
Marcin Miszczyk
MFM F Fast
M F Fast
Background and Aims: Stereotactic arrhythmia radioablation (STAR) is increasingly used for refractory ventricular tachycardia (VT), yet prospective multicentre outcome data remain limited. Here, the planned interim analysis of the prospective Standardized Treatment and Outcome Platform for Stereotactic Therapy Of Re-entrant tachycardia by a Multidisciplinary (STOPSTORM) registry is reported. Methods: STOPSTORM is a European prospective, international, multicentre registry of patients treated with STAR. The primary efficacy endpoint was the change in sustained VT episode burden comparing the 6 months before versus the 6 months after STAR. The primary safety endpoint was the occurrence of serious adverse events (SAEs) adjudicated as possibly or probably treatment-related. Overall survival was assessed using time-to-event methods. Results: Across 28 centres, 193 patients were included (mean age 68±9 years; 88% male; 53% non-ischaemic cardiomyopathy). Median follow-up was 19 months. Among 107 evaluable patients with ≥6-month follow-up, the median VT episode burden was reduced by 80% after STAR. Among patients surviving ≥6 months, 72% were free from implantable cardioverter-defibrillator (ICD) shock. In the full cohort, 12 SAEs were adjudicated as possibly or probably treatment-related, including pericardial effusion, coronary events, and early post-treatment ventricular arrhythmia. Overall survival probability was 77% at 12 months. Conclusions: In the largest prospective multicentre cohort reported to date, STAR was associated with a substantial reduction in VT burden and ICD shocks, with a low frequency of possibly or probably treatment-related SAEs.

11 January 2021 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
JPJiří Plášek
Jiří Plášek
DWDan Wichterle
Dan Wichterle
PPPetr Peichl
Petr Peichl
RČRobert Čihák
Robert Čihák
PJPatrik Jarkovský
Patrik Jarkovský
JKJosef Kautzner
Josef Kautzner

3 December 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JPJiří Plášek
Jiří Plášek
MLMarie Lazárová
Marie Lazárová
JDJozef Dodulik
Jozef Dodulik
PŠPatrik Šulc
Patrik Šulc
David StejskalDavid Stejskal
David Stejskal
JVJan Václavík
Jan Václavík
Secretoneurin (SN) is a 33 amino-acid evolutionary conserved neuropeptide from the chromogranin peptide family. SN’s main effects may be cardioprotective and are believed to be mediated through its inhibition of calmodulin-dependent kinase II (CaMKII), which influences intracellular calcium handling. SN inhibition of CaMKII suppresses calcium leakage from the sarcoplasmic reticulum through the ryanodine receptor. This action may reduce the risk of ventricular arrhythmias and calcium-dependent remodelling in heart failure. SN is also involved in reducing the intracellular reactive oxygen species concentration, modulating the immune response, and regulating the cell cycle, including apoptosis. SN can predict mortality in different disease states, beyond the classical risk factors and markers of myocardial injury. Plasma SN levels are elevated soon after an arrhythmogenic episode. In summary, SN is a novel biomarker with potential in cardiovascular medicine, and probably beyond.

25 April 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JPJiří Plášek
Jiří Plášek
TRTomáš Rychlý
Tomáš Rychlý
DDDiana Drieniková
Diana Drieniková
OCOndřej Cisovský
Ondřej Cisovský
TGTomáš Grézl
Tomáš Grézl
JVJan Václavík
Jan Václavík
Background: Two-dimensional (2D) and three-dimensional (3D) speckle-tracking echocardiography (STE) enables assessment of myocardial function. Here, we examined the agreement between 2D and 3D STE measurement of a global longitudinal strain (GLS) in patients with normal left ventricle, reduced ejection fraction, and cardiac pacing. Methods: Our analysis included 90 consecutive patients (59% males; average age: 73.2 ± 11.2 years) examined between May 2019–December 2020, with valid 2D and 3D loops for further speckle-tracking strain analysis. Linear regression, Pearson correlation, and a Bland–Altman plot were used to quantify the association between 2D and 3D GLS and related segments, using the 17-segment American Heart Association (AHA) model. Analyses were performed in the entire study group and subgroups. Intra- and inter-observer variability of 2D and 3D GLS measurement was also performed in all participants. Results: We observed a strong correlation between 2D and 3D GLS measurements (R = 0.76, p < 0.001), which was higher in males (R = 0.78, p < 0.001) than females (R = 0.69, p < 0.001). Associated segment correlation was poor (R = 0.2–0.5, p < 0.01). The correlation between 2D and 3D GLS was weaker in individuals with ventricular pacing of >50% (R = 0.62, p < 0.001) than <50% (R = 0.8, p < 0.001), and in patients with LVEF of 35% (R = 0.72, p < 0.001). Intra-observer variability for 2D and 3D GLS was 2 and 2.3%, respectively. Inter-observer variability for 2D and 3D GLS was 3.8 and 3.6%, respectively Conclusion: Overall 2D and 3D GLS were closely associated but not when analyzed per segment. It seems that GLS comparison is more representative of global shortening than local displacement. Right ventricular pacing and reduced left ventricular ejection fraction were associated with a reduced correlation between 2D and 3D GLS.