Taiyi Zhang

Dr. Taiyi Zhang

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 July 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
TZTaiyi Zhang
Taiyi Zhang
FDFeng Ding
Feng Ding
YYYujing Yang
Yujing Yang
GZGaozhen Zhao
Gaozhen Zhao
CZChuanhao Zhang
Chuanhao Zhang
Xiaowen HuangXiaowen Huang
Xiaowen Huang
In vitro diagnosis (IVD) has become a hot topic in laboratory research and achievement transformation. However, due to the high cost, and time-consuming and complex operation of traditional technologies, some new technologies are being introduced into IVD, to solve the existing problems. As a result, IVD has begun to develop toward point-of-care testing (POCT), a subdivision field of IVD. The pandemic has made governments and health institutions realize the urgency of accelerating the development of POCT. Microfluidic paper-based analytical devices (μPADs), a low-cost, high-efficiency, and easy-to-operate detection platform, have played a significant role in advancing the development of IVD. μPADs are composed of paper as the core material, certain unique substances as reagents for processing the paper, and sensing devices, as auxiliary equipment. The published reviews on the same topic lack a comprehensive and systematic introduction to μPAD classification and research progress in IVD segmentation. In this paper, we first briefly introduce the origin of μPADs and their role in promoting IVD, in the introduction section. Then, processing and detection methods for μPADs are summarized, and the innovative achievements of μPADs in IVD are reviewed. Finally, we discuss and prospect the upgrade and improvement directions of μPADs, in terms of portability, sensitivity, and automation, to help researchers clarify the progress and overcome the difficulties in subsequent μPAD research.

10 June 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
XLXiaoli Liu
Xiaoli Liu
HLHuichao Lin
Huichao Lin
JSJiaao Song
Jiaao Song
TZTaiyi Zhang
Taiyi Zhang
XWXiaoying Wang
Xiaoying Wang
CZchengyun zheng
chengyun zheng
Cell culture is important for the rapid screening of anti-cancer drug candidates, attracting intense interest. Traditional 2D cell culture has been widely utilized in cancer biological research. However, 3D cellular spheroids are able to recapitulate the in vivo microenvironment of tissues or tumors. Thus far, several 3D cell culture methods have been developed, for instance, the hanging drop method, spinner flasks and micropatterned plates. Nevertheless, these methods have been reported to have some disadvantages, for example, medium replacement is inconvenient or causes cellular damage. Here, we report on an easy-to-operate and useful micro-hole culture chip (SimpleDrop) for 3D cellular spheroid formation and culture and drug analysis, which has advantages over the traditional method in terms of its ease of operation, lack of shear force and environmentally friendliness. On this chip, we observed the formation of a 3D spheroid clearly. Three drugs (paclitaxel, cisplatin and methotrexate) were tested by both cell viability assay and drug-induced apoptotic assay. The results show that the three drugs present a similar conclusion: cell viability decreased over time and concentration. Moreover, the apoptotic experiment showed a similar trend to the live/dead cell assay, in that the fraction of the apoptotic and necrotic cells correlated with the concentration and time. All these results prove that our SimpleDrop method is a useful and easy method for the formation of 3D cellular spheroids, which shows its potential for both cell–cell interaction research, tissue engineering and anticancer drug screening.

15 March 2022 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
LHLijuan Hou
Lijuan Hou
LZLimin Zhang
Limin Zhang
JZJinhao Zang
Jinhao Zang
WSWeixia Shen
Weixia Shen
TZTaiyi Zhang
Taiyi Zhang
TXTingting Xu
Tingting Xu
K0.8Ti1.73Li0.27O4 (KLTO) is an important titanium-based anode material for lithium-ion batteries (LIBs) and is expected to become an alternative to carbonaceous materials on account of its nontoxicity, low cost, and high safety performance. However, it suffers from poor specific capacity at high charge–discharge rates due to its low conductivity and obstructed Li-ion diffusion. In this work, an Fe-doped KLTO@rGO (Fe-KLTO@rGO) composite prepared by following a simple electrostatic assembly process and its high-rate and long-cycle-life-performance as an anode in LIBs is obtained. The Fe-KLTO@rGO composite sample has an excellent specific capacity of 330 and 105 mAh g−1 at a current density of 1 C (1 C = 175 mA g−1) and 50 C, respectively. In addition, the Fe-KLTO@rGO composite sample can carry out a long cycle of 3000 cycles at a rate of 50 C, and the specific capacity remains at 127 mAh g−1.

17 June 2021 in Journal of Materials Chemistry C
Verified
Journal Article
Closed access
PDF file
LZLimin Zhang
Limin Zhang
DKDezhi Kong
Dezhi Kong
QZQianqian Zhuang
Qianqian Zhuang
MWMinglang Wang
Minglang Wang
TZTaiyi Zhang
Taiyi Zhang
Xiaowen HuangXiaowen Huang
Xiaowen Huang
We prepared 1T-PtSe 2 films on a flexible carbon cloth through a facile yet effective approach. The optimized samples exhibit a low overpotential of 177 mV and a favorable Tafel slope of 67 mV dec −1 with good stability.

3 December 2025 in Materials Chemistry Frontiers
Verified
Journal Article
Closed access
PDF file
TZTaiyi Zhang
Taiyi Zhang
YJYingying Jing
Yingying Jing
ZWZhao Wang
Zhao Wang
WWWen-Xiu Wu
Wen-Xiu Wu
YPYen Leng Pak
Yen Leng Pak
JSJibin Song
Jibin Song
Room-temperature phosphorescence (RTP) materials have received widespread attention in the fields of optoelectronics and biomedical sciences due to their extremely long phosphorescence lifetimes and unique time-resolved properties.

29 September 2023 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
WSWeidu Song
Weidu Song
CZChuanhao Zhang
Chuanhao Zhang
HLHuichao Lin
Huichao Lin
TZTaiyi Zhang
Taiyi Zhang
HLHaixia Liu
Haixia Liu
Xiaowen HuangXiaowen Huang
Xiaowen Huang
The rapid quantitative detection of Pseudomonas aeruginosa in milk is of great significance to food safety. Quantitative real-time polymerase chain reaction (qPCR) technology is a good choice to meet this requirement. A good qPCR system should show the advantages of being low cost, having low-power consumption, having potential for miniaturization and be portable. However, most of the time-domain-based qPCR systems reported to date do not meet these requirements. In this study, we propose a novel real-time rotary PCR reaction system (RRP) that meets all the abovementioned specifications, and contains four modules: a heating control module, a disposable PCR capillary tube, a mechanical control module, and a photoelectric detection module. The volume of our homemade-PCR capillary tube is only 3 μL. The total manufacturing cost is cheaper than $200, and the capillary tube is about 1.4 cents. The size parameter of the RRP is less than 300 mm × 150 mm × 150 mm, using low mobile power sources to operate. All the features mean that the RRP meets the advantages of low sample volumes, enhanced thermal conductivity and being portable. Through conducting the experimental quantitative detection of Pseudomonas aeruginosa in milk and theoretical simulations by COMSOL, we prove the feasibility of this rotary PCR real-time detection system, which has broad application prospects in the rapid detection of bacteria and food safety.