Arathi Murugesan

Arathi Murugesan


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

20 March 2020 in Journal of Orthodontics
Verified
Journal Article
Closed access
PDF file
AMArathi Murugesan
Arathi Murugesan
ASArvind Sivakumar
Arvind Sivakumar
To compare the measured values obtained from the plaster model, digital models created by scanning the plaster models and direct intraoral scanning with the values obtained from direct intraoral measurements. This was a prospective clinical study. The study was conducted in Department of Orthodontics, Saveetha Dental College and Hospital, Tamil Nadu, India. Ten patients before the start of orthodontic treatment were selected for the study. A computer-aided design and manufacturing (CAD-CAM) system is an advanced technology that is being adopted in the field of orthodontics for diagnosis, treatment planning and documentation of patient records. Mesiodistal tooth width measurements of first premolars, canines, lateral incisors and central incisors, and transverse width measurement from mesial pit of right first premolar to mesial pit of left first premolar in both maxilla and mandible were obtained from direct intraoral measurement (gold standard), study model obtained from alginate impression, intraoral scanned image, and desktop scanned image of the study model. Descriptive statistics and ANOVA was performed to find the difference in mean among the groups. A P value > 0.05 was obtained in ANOVA indicating that there is no statistically significant difference in the measurements obtained by either of the methods. Conventional stone models and digital models obtained from intraoral scan and desktop scanning of plaster models are clinically reliable as the variations in measurements obtained from these methods were clinically negligible.

26 October 2022 in Medical Science Monitor
Verified
Journal Article
Open access
AMArathi Murugesan
Arathi Murugesan
SDS.P. Saravana Dinesh
S.P. Saravana Dinesh
SPSrirengalakshmi Muthuswamy Pandian
Srirengalakshmi Muthuswamy Pandian
LSLichi Ashwin Solanki
Lichi Ashwin Solanki
AAAbdulrahman Alshehri
Abdulrahman Alshehri
Shankargouda PatilShankargouda Patil
Shankargouda Patil
Background: In this study, we aimed to evaluate orthodontic mini-implant placement in the maxillary anterior alveolar region by cone beam computed tomography (CBCT) in 15 patients at a single center in South India. Material/Methods: A total of 15 CBCT scans of orthodontic patients after completion of leveling and aligning stage were included. The thickness of labial alveolar bone, labio-palatal bone, and inter-radicular distance between the maxillary central incisors (U1-U1), maxillary central and lateral incisor (U1-U2), and maxillary lateral incisor and canine (U2-U3) at vertical levels 4 mm, 6 mm, and 8 mm above the interdental cementoenamel junction were measured. Descriptive statistics, ANOVA, and Tukey post hoc tests were done to assess the differences among the groups. An independent t test was done to analyze differences by sex. Results: The thickness of cortical bone in the labial region was higher in the U2-U3 site than in the U1-U1 site, at a height of 4 mm. Also, there was a significant difference between 4 mm and 8 mm heights in the U2-U3 region. No significant difference was noted in bone dimensions among men and women and in the labio-palatal bone thickness among the different sites. The inter-radicular distance was the highest between the U2-U3 site, while it was the lowest in the U1-U2 site. Conclusions: The findings from this center showed that when CBCT was used to evaluate orthodontic mini-implant placement in the maxillary anterior alveolar region, the U2-U3 and U1-U1 locations at heights between 6 mm to 8 mm apical to the interdental cementoenamel junction were optimal for placement of the mini-implants.

3 July 2021 in Orthodontic Waves
Verified
Journal Article
Closed access
AMArathi Murugesan
Arathi Murugesan
NRNavaneethan R
Navaneethan R
Objective : The present study was aimed to analyse the efficacy of specs loop, a newly designed closing loop. Materials and Methods : A finite element maxillary model for en-masse anterior retraction was made. The newly designed specs loop was tested with different preactivation bends (alpha-30 degree; beta-15 degree, 30 degree and 45 degree) and without preactivation bends. The horizontal and vertical forces and moments at both the alpha and beta nodes and overall moment to force ratio, range of crown tip, root tip and vertical movement of all the individual teeth, stress acting on the teeth and bone were calculated for each group for a horizontal activation of 3 mm using Abaqus software. Results : Stress acting on the teeth and bone decreased with increasing beta bend. Moment-to-force (M/F) ratio acting on the anterior teeth was approximately 10:1 with preactivation bends of alpha 30 degrees and beta degrees 15, 30 and 45 degrees whereas the M/F ratio was only 2:1 without the preactivation bends. With increasing beta bend, distal crown tip of the teeth and the extrusive movement of the posteriors increased while the extrusive movements of the anterior decreased. Conclusion : The specs loop with preactivation bends can be efficiently used for en-masse anterior retraction.

20 March 2022 in Clinical and Investigative Orthodontics
Verified
Journal Article
Open access
AMArathi Murugesan
Arathi Murugesan
RNR. Navaneethan
R. Navaneethan
T loop is one of the most commonly used loops for space closure. But the previous literature shows that T loop produces a moment to force ratio of less than the ideal value with high load deflectio...

1 January 2021 in Annals of Orthodontics and Periodontics Specialty
Verified
Journal Article
Open access
PDF file
AMArathi Murugesan
Arathi Murugesan
SDSaravana Dinesh
Saravana Dinesh
NBNivethigaa Balakrishnan
Nivethigaa Balakrishnan
Racial, ethnic, sexual, and nutritional variances all have an impact on malocclusion and craniofacial growth in the South Indian inhabitants which is diverse in terms of ethnicity and culture. Therefore, the assessment and diagnosis of craniofacial anomalies depend critically on the availability of standard standards for the local population . The purpose of the study was to evaluate the accuracy of Schwarz's analysis in determining mandibular length in the population of South India. One hun