Within China, brick dwellings stand as archetypal relics of traditional habitation, embodying a “living fossil” status. The sustainability of these dwellings is contingent upon the integration of energy-conservation strategies. This study scrutinized and empirically assessed a representative dwelling in the Peking area. Using numerical simulations, the impact on energy consumption of factors such as insulation and glazing type, external wall thickness, insulation thickness, and solar energy utilization was evaluated. The outcomes reveal that introducing external thermal insulation—specifically, expanded polystyrene panels with a thickness of 60 mm and 40 mm for the roof and exterior walls, respectively—along with a sunspace of depth 1.5 m yielded superior energy efficiency. Additionally, substituting conventional roofing with solar tiles exhibited a potential annual electricity generation coupled with an annual solar radiation conversion efficiency of 17%. Collectively, these strategies induced a substantial reduction in annual energy consumption. This study presents tailored energy-conservation measures and provides design decision support for architects’ practical recommendations on thermal environment control of passive traditional dwellings in the Peking area.
Aging populations have intensified the demand for thermally comfortable and energy-efficient housing, particularly for elderly residents whose diminished thermoregulatory capacity renders them disproportionately vulnerable to indoor temperature fluctuations. Existing senior apartments in cold-climate regions frequently fail to meet age-specific thermal comfort standards, yet systematic retrofit optimization frameworks explicitly tailored to elderly occupants remain scarce. This study presents a data-driven multi-objective optimization framework for building envelope retrofitting, which is validated using on-site temperature measurements from a representative 1980s brick–concrete senior apartment building in Beijing. The framework integrates Latin Hypercube Sampling (LHS) for design space exploration, a Long Short-Term Memory (LSTM) surrogate model for simultaneous prediction of three performance objectives, and Non-dominated Sorting Genetic Algorithm II (NSGA-II) for Pareto-optimal solution generation, with final selection performed via a weighted Mahalanobis distance-based Technique for Order Preference by Similarity to an Ideal Solution (TOPSIS). Optimization targets—annual energy consumption, indoor thermal discomfort hours, and retrofit cost—are parameterized using the age-sensitive comfort thresholds specified in GB 50340-2016. The LSTM surrogate achieved R2 values of 0.91–0.93 across all objectives with training–testing differences below 0.02. The optimal retrofit package—Polyvinyl Chloride (PVC) Low Emissivity (Low-E) double-glazed windows (5 + 6A + 5), glass fiber roof insulation (65.25 mm), and Extruded Polystyrene (XPS) external wall insulation (65.39 mm)—reduces annual energy consumption by 47.1% (from 40,867 to 21,626 kWh) and annual thermal discomfort hours by 62.4% (from 2454 °C·h to 923 °C·h). SHapley Additive exPlanations (SHAP)-based sensitivity analysis further identifies wall U-value and roof thickness as the dominant performance drivers. A reproducible and computationally efficient pathway is provided by the proposed framework for evidence-based envelope retrofit decision-making in existing senior residential buildings.