Chandrashekhar Narayan Bhende

Prof. Chandrashekhar Narayan Bhende

School of Electrical Sciences, Indian Institute of Technology Bhubaneswar, Odisha 752050, India

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2021 in IEEE Systems Journal
Verified
Journal Article
Closed access
NSNikhil Kumar Sharma
Nikhil Kumar Sharma
SSSubhransu Ranjan Samantaray
Subhransu Ranjan Samantaray
Chandrashekhar Narayan BhendeChandrashekhar Narayan Bhende
Chandrashekhar Narayan Bhende
The utilization of low-voltage direct current (LVdc) distribution system is gaining popularity in recent years due to its numerous advantages. However, the development of efficient fault detection scheme for an LVdc microgrid is a challenging problem. This article proposes a fast and effective variational mode decomposition (VMD)-based fault detection technique for the LVdc distribution system with penetration of renewable sources using the local end current measurements only. This scheme processes the rate of change of current signal of the distribution lines through the VMD algorithm that decomposes it to different modes. The cumulative energy of the most significant mode is being computed and used as a fault detection index. The proposed scheme is tested for pole to pole and pole to ground fault with broad variation in fault location, fault resistance, and distributed generations penetration in grid-connected and islanding mode of microgrid operation. The performance of the proposed technique is compared with the existing differential current and overcurrent relaying scheme as well as other existing schemes. The testing has been done in MATLAB/Simulink and Typhoon hardware-in-loop testbed. The proposed scheme detects all types of fault with wide variation in fault and operating conditions of the microgrid with faster response time. The test results indicate that the proposed protection scheme is a potential candidate for providing effective protection measure for LVdc microgrid.

26 August 2014 in Energy Systems
Verified
Journal Article
Closed access
PDF file
CPChittaranjan Pradhan
Chittaranjan Pradhan
Chandrashekhar Narayan BhendeChandrashekhar Narayan Bhende
Chandrashekhar Narayan Bhende

1 July 2015 in ISA Transactions
Verified
Journal Article
Closed access
AGArun Ghosh
Arun Ghosh
SMSiva Ganesh Malla
Siva Ganesh Malla
Chandrashekhar Narayan BhendeChandrashekhar Narayan Bhende
Chandrashekhar Narayan Bhende

1 March 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SNSidharthenee Nayak
Sidharthenee Nayak
DDDivyanshi Dwivedi
Divyanshi Dwivedi
KBK. Victor Sam Moses Babu
K. Victor Sam Moses Babu
Chandrashekhar Narayan BhendeChandrashekhar Narayan Bhende
Chandrashekhar Narayan Bhende
PYPradeep Kumar Yemula
Pradeep Kumar Yemula
MPMayukha Pal
Mayukha Pal
The availability of high-fidelity time-series data is essential for distribution grid operations such as state estimation, prediction, protection and scheduling of distributed energy resources. However, disruptions in the metering systems, such as latency, equipment malfunctions, and communication congestion, could lead to missing data points. In this paper, we propose a fully data-driven approach for the distribution grid aimed at imputing the missing data from distributed-phasor measurement units (D-PMU). An advanced method is proposed named self-attention-based imputation for time series (SAITS) which is adapted to handle the complex and diverse data found in digital substations. The proposed method has the ability to accurately impute data even during fault events, thereby mitigating the potential misoperation of protection devices. This enables accurate data imputation and reconstruction of missing data points, thereby preserving the continuity and integrity of the dataset. We have validated the performance of the proposed method by comparing it with various traditional methods. By implementing the proposed imputation technique, the accuracy, and reliability are significantly improved, which enhances the decision-making processes for digital substations.

15 June 2021 in IEEE Systems Journal
Verified
Journal Article
Closed access
GMG N V Mohan
G N V Mohan
Chandrashekhar Narayan BhendeChandrashekhar Narayan Bhende
Chandrashekhar Narayan Bhende
ASAnurag Srivastava
Anurag Srivastava
Natural disasters and accidents have underscored the need for operative solutions that can enhance the resiliency of power distribution network (PDN). This article proposes novel methods of scheduling of battery energy storage system (BESS) and loads of microgrid to enhance the resiliency of PDN. A mixed-integer linear programming model is developed to minimize the energy mismatch between available resources and critical loads during outage period. The proposed model is aimed at minimizing the shedding of high critical loads (hcl) and maximizing the serving time of hcl during outages. In order to increase the longevity of the load serving, the fuzzy-based approach is developed to control the C_rate of the BESS. Moreover, to increase the resiliency of hcl, partitioning of BESS capacity is proposed, which provides more flexibility for charging/discharging control of the BESS. The concept of variable dispatch interval is introduced to reduce the frequent switching of loads. By considering the reactive power, an apparent power resiliency metric is proposed to quantify the resiliency of PDN. The IEEE 33-bus network is tested under various restoration periods in order to verify the performance of the proposed methodology in the MATLAB environment.

26 August 2016 in Electric Power Components and Systems
Verified
Journal Article
Closed access
CPChittaranjan Pradhan
Chittaranjan Pradhan
Chandrashekhar Narayan BhendeChandrashekhar Narayan Bhende
Chandrashekhar Narayan Bhende
This article focuses on fuzzy logic-based primary frequency regulation of doubly fed induction generator type variable-speed wind turbine generators. Wind turbine generators can be operated at a deloading power point with a reduced power level instead of maximum power point. Deloading operation makes the reserve power available, which can be utilized to stabilize the power system for frequency regulation during active power mismatch between generation and demand. The droop control is implemented as supplementary control to improve the short-term frequency dynamics. In this article, the deloading parameter and droop parameter of wind turbine generators are dynamically adjusted by using a fuzzy-based controller that mitigates system frequency transients. The combination of fuzzy-based dynamic deloading and variable droop operation gives better power system performance in terms of frequency excursion and increases the output power extracted from the deloaded wind turbine generator. Hence, proposed the fuzzy-based droop and deloading scheme not only increases overall annual capacity factor of wind farm but also reduces fuel consumption when diesel generators are operated along with wind turbines. The effectiveness of the proposed fuzzy-based control scheme is validated on an IEEE 9-bus test system.