Jun Miao

Dr. Jun Miao


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2023 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
ZGZiming Geng
Ziming Geng
JWJian Wang
Jian Wang
GCGuangdong Chen
Guangdong Chen
JLJianchao Liu
Jianchao Liu
JLJie Lan
Jie Lan
JMJun Miao
Jun Miao
Background: Although previous studies have suggested a close association between gut microbiota (GM) and intervertebral disc degeneration (IVDD), the causal relationship between them remains unclear. Hence, we thoroughly investigate their causal relationship by means of a two-sample Mendelian randomization (MR) study, aiming to determine the impact of gut microbiota on the risk of developing intervertebral disc degeneration. Methods: Summary data from genome-wide association studies of GM (the MiBioGen) and IVDD (the FinnGen biobank) have been acquired. The inverse variance weighted (IVW) method was utilized as the primary MR analysis approach. Weighted median, MR-Egger regression, weighted mode, and simple mode were used as supplements. The Mendelian randomization pleiotropy residual sum and outlier (MR-PRESSO) and MR-Egger regression were performed to assess horizontal pleiotropy. Cochran's Q test evaluated heterogeneity. Leave-one-out sensitivity analysis was further conducted to determine the reliability of the causal relationship. A reverse MR analysis was conducted to assess potential reverse causation. Results: We identified nine gut microbial taxa that were causally associated with IVDD (P < 0.05). Following the Benjamini–Hochberg corrected test, the association between the phylum Bacteroidetes and a higher risk of IVDD remained significant (IVW FDR-corrected P = 0.0365). The results of the Cochrane Q test did not indicate heterogeneity (P > 0.05). Additionally, both the MR-Egger intercept test and the MR-PRESSO global test revealed that our results were not influenced by horizontal pleiotropy (P > 0.05). Furthermore, the leave-one-out analysis substantiated the reliability of the causal relationship. In the reverse analysis, no evidence was found to suggest that IVDD has an impact on the gut microbiota. Conclusion: Our results validate the potential causal impact of particular GM taxa on IVDD, thus providing fresh insights into the gut microbiota-mediated mechanism of IVDD and laying the groundwork for further research into targeted preventive measures.

1 February 2023 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
JWJincheng Wu
Jincheng Wu
QFQing Feng
Qing Feng
DYDongmei Yang
Dongmei Yang
HXHanpeng Xu
Hanpeng Xu
WWWangqiang Wen
Wangqiang Wen
JMJun Miao
Jun Miao
Objective: To study the biomechanical characteristics of various tissue structures of different sizes of 3D printed Cage in lumbar interbody fusion. Methods: A finite element model of normal spine was reconstructed and verified. Pedicle screws and Cage of different sizes were implanted in the L4/5 segment to simulate lumbar interbody fusion. The range of motion of the fixed and cephalic adjacent segment, the stress of the screw-rod system, the stress at the interface between cage and L5 endplate, and intervertebral disc pressure of the adjacent segment were calculated and analyzed. Results: The range of motion and intervertebral disc pressure of the adjacent segment of each postoperative model were larger than those of the intact model, but there was not much difference between them. The stress of cage-endplate interface was also larger than that of the intact model. However, the difference is that the stress of the endplate and the screw-rod system has a tendency to decrease with the increase of the axial area of cage. Conclusions: Cage with larger axial area in lumbar interbody fusion can reduce the stress of internal fixation system and endplate, but will not increase the range of motion and intervertebral disc pressure of adjacent segment. It has a certain effect in preventing the cage subsidence, internal fixation system failure and screw rod fracture.

11 April 2023 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
YLYang Liu
Yang Liu
DLDao-Kuo Liu
Dao-Kuo Liu
ZWZhi-Wei Wang
Zhi-Wei Wang
CZChong Zhao
Chong Zhao
JMJun Miao
Jun Miao
Background: Nucleus pulposus (NP) cell apoptosis contributed to disc degeneration. Baicalein, a natural steroid saponin, has been demonstrated to have anti-inflammatory, antiapoptotic, and antioxidative effects in various diseases.However, little is known about the roles of baicalein in intervertebral disc degeneration.Methods: To evaluate the roles of baicalein in disc degeneration and its specific mechanism, human NP cells were incubated with TNF-α and various concentrations of baicalein. Cell viability, extracellular matrix protein expression, catabolic factors, degree of apoptosis, inflammatory factors, and related signaling pathways were evaluated by western blotting, fluorescence immunostaining, TUNEL staining, and reverse transcription PCR.Results: Baicalein inhibited TNF-α-activated apoptotic signaling and catabolic activity in NP cells. Baicalein promoted PI3K/Akt signaling and attenuated the level of apoptosis-related markers in TNF-α-stimulated human NP cells.Conclusion: Our work provides that baicalein attenuates TNF-α-activated apoptosis in human NP cells through promoting the PI3K/Akt pathway, indicating that baicalein is a new potential candidate for clinical therapy to attenuate disc degeneration.

1 January 2024 in Journal of Pain Research
Verified
Journal Article
Open access
PDF file
ZGZiming Geng
Ziming Geng
JWJian Wang
Jian Wang
JLJianchao Liu
Jianchao Liu
JMJun Miao
Jun Miao
Purpose: Adult degenerative scoliosis (ADS) research lacks bibliometric analysis, despite numerous studies. This study aimed to systematically analyze the development, current status, hot topics, frontier areas, and trends in ADS research. Patients and Methods: A systematic literature review was conducted in the Web of Science Core Collection database from January 1998 to June 2023. Information regarding the country, institution, author, journal, and keywords was collected for each article. Bibliometric analysis was performed using VOSviewer and Citespace software. Results: The final analysis covered 1695 publications, demonstrating a steady increase in ADS research. The United States was the most prolific and influential country with 684 publications, followed by China and Japan. The University of California System was the most productive institution with 113 publications. Shaffrey, CI (47 publications) and Lenke, LG (41 publications) were top authors. The analysis revealed seven main research clusters: “intervertebral disc”, “adult spinal deformity”, “lumbar fusion”, “minimally invasive surgery”, “navigation”, “postoperative complications”, and “mental retardation”. Keywords with strong bursts of activity included degeneration, prevalence, imbalance, classification, lumbar spinal stenosis, and kyphosis. Conclusion: In conclusion, in recent years, ADS research has undergone rapid development. This study analyzed its hot topics, advancements, and research directions, making it the latest bibliometric analysis in this field. The findings aim to provide a new perspective and guidance for clinical practitioners and researchers.

4 November 2022 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
HXHanpeng Xu
Hanpeng Xu
XWXiaodong Wang
Xiaodong Wang
YHYe Han
Ye Han
YJYuanyuan Jiang
Yuanyuan Jiang
JWJianzhong Wang
Jianzhong Wang
JMJun Miao
Jun Miao
Objective: To analyse and compare the biomechanical differences between 3D-printed prostheses, titanium mesh cages and poorly matched titanium mesh cages in total en bloc spondylectomy (TES). Methods: The finite element model of T10-L2 for healthy adults was modified to make three models after T12 total spondylectomy. These models were a 3D-printed prosthesis, titanium mesh cage and prosthesis-endplate mismatched titanium mesh cage for reconstruction. The range of motion (ROM), stress distribution of the endplate and internal fixation system of three models in flexion and extension, lateral bending and axial rotation were simulated and analysed by ABAQUS. Result: In flexion, due to the support of the anterior prosthesis, the fixation system showed the maximum fixation strength. The fixation strength of the 3D-printed prosthesis model was 26.73 N·m /°, that of the TMC support model was 27.20 N·m /°, and that of the poorly matched TMC model was 24.16 N·m /°. In flexion, the L1 upper endplate stress of the poorly matched TMC model was 35.5% and 49.6% higher than that of the TMC and 3D-printed prosthesis, respectively. It was 17% and 28.1% higher in extension, 39.3% and 42.5% higher in lateral bending, and 82.9% and 91.2% higher in axial rotation, respectively. The lower endplate of T11 showed a similar trend, but the magnitude of the stress change was reduced. In the stress analysis of the 3D-printed prosthesis and TMC, it was found that the maximum stress was in flexion and axial rotation, followed by left and right bending, and the least stress was in extension. However, the mismatched TMC withstood the maximum von Mises stress of 418.7 MPa (almost twice as much as the buckling state) in rotation, 3 times and 5.83 times in extension, and 1.29 and 2.85 times in lateral bending, respectively. Conclusion: Different prostheses with good endplate matching after total spondylectomy can obtain effective postoperative stable support, and the reduction in contact area caused by mismatch will affect the biomechanical properties and increase the probability of internal fixation failure.

12 February 2018 in Orthopaedic Surgery
Verified
Journal Article
Open access
PDF file
JSJun Sun
Jun Sun
YLYan‐Cheng Liu
Yan‐Cheng Liu
SYSong‐Hua Yan
Song‐Hua Yan
SWSha‐Sha Wang
Sha‐Sha Wang
DLD Kevin Lester
D Kevin Lester
KZKuan Zhang
Kuan Zhang
Objective: The third generation Intelligent Device for Energy Expenditure and Activity (IDEEA3, MiniSun, CA) has been developed for clinical gait evaluation, and this study was designed to evaluate the accuracy and reliability of IDEEA3 for the gait measurement of lumbar spinal stenosis (LSS) patients.Methods: Twelve healthy volunteers were recruited to compare gait cycle, cadence, step length, velocity, and number of steps between a motion analysis system and a high‐speed video camera. Twenty hospitalized LSS patients were recruited for the comparison of the five parameters between the IDEEA3 and GoPro camera. Paired t‐test, intraclass correlation coefficient, concordance correlation coefficient, and Bland–Altman plots were used for the data analysis.Results: The ratios of GoPro camera results to motion analysis system results, and the ratios of IDEEA3 results to GoPro camera results were all around 1.00. All P‐values of paired t‐tests for gait cycle, cadence, step length, and velocity were greater than 0.05, while all the ICC and CCC results were above 0.950 with P < 0.001.Conclusions: The measurements for gait cycle, cadence, step length, velocity, and number of steps with the GoPro camera are highly consistent with the measurements with the motion analysis system. The measurements for IDEEA3 are consistent with those for the GoPro camera. IDEEA3 can be effectively used in the gait measurement of LSS patients.