Liquid film thickness measurements under temperature-varying conditions in a two-phase flow are of great importance to refining our understanding of two-phase flows. In order to overcome the limitations of the conventional electrical means of measuring the thickness of a liquid film, this study proposes a three-electrode conductance method, with the device fabricated on a flexible printed circuit board (FPCB). The three-electrode conductance method offers the advantage of applicability under conditions with varying temperatures in principle, while the FPCB has the advantage of usability on curved surfaces and in relatively high-temperature conditions in comparison with sensors based on a printed circuit board (PCB). Two types of prototype sensors were fabricated on an FPCB and the feasibility of both was confirmed in a calibration test conducted at different temperatures. With the calibrated sensor, liquid film thickness measurements were conducted via a falling liquid film flow experiment, and the working performance was tested.
The advanced thermal-hydraulic test loop for accident simulation (ATLAS) was developed and operated at The Korea Atomic Energy Research Institute. The ATLAS is operated to simulate accidents in pressurized water reactors (PWRs). A domestic standard problem (DSP) using the ATLAS was proposed for transferring the database of the integral effect test to Korean nuclear researchers and developing the safety analysis methodology of PWRs. The fourth DSP (DSP-04) exercise was performed during 2015–2017 with 15 participants (13 organizations), that are universities, government, and nuclear industries. In DSP-04, a top-slot break at the cold leg was chosen as the target scenario to resolve an issue about the effect of loop seal clearing and the reformation on the peak cladding temperature during the cold leg top-slot break LOCA for APR1400. The participants performed a code calculation for the experimental simulation and sensitivity studies for the enhancement of the code. This paper includes brief information about the experimental and major code assessment results.
A test called B4.2 in the OECD-ATLAS2 project was performed to simulate loss of the residual heat removal system (RHRS) during mid-loop operation (MLO) using a thermal-hydraulic (T-H) integral-effect test facility: the Advanced Thermal-Hydraulic Test Loop for Accident Simulation (ATLAS). The main purpose of this test was to investigate a T-H transient in the reactor coolant system (RCS) during loss of the RHRS and to evaluate the effectiveness of reflux condensation and the capability of a safety injection tank (SIT) on shutdown coolability. The initial and boundary conditions for the B4.2 test were appropriately determined according to a state of MLO corresponding to 65 h after reactor trip in the Advanced Power Reactor 1400 MW(electric) (APR1400). During the loss of RHRS accident transient simulation, major T-H parameters such as system pressures, temperatures, and collapsed water levels in the RCS were measured, and unique T-H phenomena such as reflux/cocurrent condensations, off-take, countercurrent flow, and countercurrent flow limitation were investigated. In this paper, the overall T-H behavior in the RCS during a simulated loss of the RHRS with SITs is highlighted to provide a better understanding of T-H phenomena regarding coolability with reflux condensation.