Pierre DROUIN

Mr. Pierre DROUIN


Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2007 in Fundamental & Clinical Pharmacology
Verified
Journal Article
Closed access
PDF file
AKAnna Kearney‐Schwartz
Anna Kearney‐Schwartz
JVJean‐Marc Virion
Jean‐Marc Virion
JSJean‐François Stoltz
Jean‐François Stoltz
PDPierre DROUIN
Pierre DROUIN
FZFaiez Zannad
Faiez Zannad

1 September 1999 in Clinical Chemistry
Verified
Journal Article
Open access
PDF file
BGBruno Guerci
Bruno Guerci
HAHelena Antebi
Helena Antebi
LMLaurent Meyer
Laurent Meyer
VDVincent Durlach
Vincent Durlach
OZOlivier Ziegler
Olivier Ziegler
PDPierre DROUIN
Pierre DROUIN
Background: We assessed the ability of LDL from 30 type 1 diabetic patients (18 men, 12 women), 65 type 2 diabetic patients (35 men, 30 women), and 35 controls (19 men, 16 women) to generate peroxides. The men and women in the diabetic groups were studied separately and matched for age, body mass index, duration of diabetes, glycohemoglobin, and conventional lipid characteristics according to the presence or absence of hyperlipidemia. Methods: The ability of LDL to form peroxides was assessed by measuring the thiobarbituric acid-reactive substances corrected for LDL-cholesterol [ratio of malondialdehyde (MDA) to LDL-cholesterol]. LDL particle size was expressed as the ratio of LDL-cholesterol to apolipoprotein B (LDL-cholesterol/apoB). Results: The MDA/LDL-cholesterol ratio was higher in type 1 and type 2 diabetic patients with hyperlipidemia than in controls. The MDA/LDL-cholesterol ratio was also higher in type 2 normolipidemic women than in controls (P <0.01). The LDL-cholesterol/apoB ratio was lower in type 2 diabetic women than in type 2 diabetic men (P <0.05). The MDA/LDL-cholesterol ratio was negatively correlated with the LDL-cholesterol/apoB ratio (r = −0.78, P <0.001) in hyperlipidemic type 1 (not type 2) diabetic patients. In normolipidemic type 2 diabetic patients, the MDA/LDL-cholesterol ratio was also negatively correlated with the LDL-cholesterol/apoB ratio (r = −0.75, P <0.001) because of the highly significant negative correlation in type 2 diabetic women (r = −0.89, P <0.01). Conclusions: LDL from well-controlled type 2 diabetic women is smaller and more prone to form peroxides. This could explain why diabetic women are at greater risk of cardiovascular disease.

7 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
RBRaphaël Brard
Raphaël Brard
LBLise Bellanger
Lise Bellanger
LCLaurent Chevreuil
Laurent Chevreuil
FDFanny Doistau
Fanny Doistau
PDPierre DROUIN
Pierre DROUIN
ASAymeric Stamm
Aymeric Stamm
Solutions to assess walking deficiencies are widespread and largely used in healthcare. Wearable sensors are particularly appealing, as they offer the possibility to monitor gait in everyday life, outside a facility in which the context of evaluation biases the measure. While some wearable sensors are powerful enough to integrate complex walking activity recognition models, non-invasive lightweight sensors do not always have the computing or memory capacity to run them. In this paper, we propose a walking activity recognition model that offers a viable solution to this problem for any wearable sensors that measure rotational motion of body parts. Specifically, the model was trained and tuned using data collected by a motion sensor in the form of a unit quaternion time series recording the hip rotation over time. This time series was then transformed into a real-valued time series of geodesic distances between consecutive quaternions. Moving average and moving standard deviation versions of this time series were fed to standard machine learning classification algorithms. To compare the different models, we used metrics to assess classification performance (precision and accuracy) while maintaining the detection prevalence at the level of the prevalence of walking activities in the data, as well as metrics to assess change point detection capability and computation time. Our results suggest that the walking activity recognition model with a decision tree classifier yields the best compromise in terms of precision and computation time. The sensor that was used had purposely low computing and memory capacity so that reported performances can be thought of as the lower bounds of what can be achieved. Walking activity recognition is performed online, i.e., on-the-fly, which further extends the range of applicability of our model to sensors with very low memory capacity.

12 December 2022 in Statistics in Medicine
Verified
Journal Article
Open access
PDPierre DROUIN
Pierre DROUIN
ASAymeric Stamm
Aymeric Stamm
LCLaurent Chevreuil
Laurent Chevreuil
VGVincent Graillot
Vincent Graillot
LBLaetitia Barbin
Laetitia Barbin
LBLise Bellanger
Lise Bellanger
Recent approaches in gait analysis involve the use of wearable motion sensors to extract spatio‐temporal parameters that characterize multiple aspects of an individual's gait. In particular, the medical community could largely benefit from this type of devices as they could provide the clinicians with a valuable tool for assessing gait impairment. Motion sensor data are however complex and there is an urgent unmet need to develop sound statistical methods for analyzing such data and extracting clinically relevant information. In this article, we measure gait by following the hip rotation over time and the resulting statistical unit is a time series of unit quaternions. We explore the possibility to form groups of patients with similar walking impairment by taking into account their walking data and their global decease severity with semi‐supervised clustering. We generalize a compromise‐based method namedhclustcomproto unit quaternion time series by combining it with the proper dissimilarity quaternion dynamic time warping. We apply this method on patients diagnosed with multiple sclerosis to form groups of patients with similar walking deficiencies while accounting for the clinical assessment of their overall disability. We also compare the compromise‐based clustering approach with the methodmergeTreesthat falls into a sub‐class of ensemble clustering named collaborative clustering. The results provide a first proof of both the interest of using wearable motion sensors for assessing gait impairment and the use of prior knowledge to guide the clustering process. It also demonstrates that compromise‐based clustering is a more appropriate approach in this context.

7 April 2026
Verified
Thesis
Closed access
PDPierre DROUIN
Pierre DROUIN
Cette thèse s’inscrit dans le contexte du projet e-Gait dont l’objectif est de développer un nouvel outil de mesure basé sur l’utilisation de systèmes numériques pour quantifier les troubles de la démarche de patients atteints de maladie neurodégénative, et plus particulièrement la Sclérose En Plaques (SEP). La solution adoptée consiste à mesurer les rotations en trois dimensions de la hanche au cours de la marche à l’aide d’un système de capteurs inertiels placé à la ceinture. Ces rotations sont représentées sous la forme d’une séquence de quaternions unitaires. Des méthodes adaptées à ce type de données sont présentées pour en extraire des informations relatives à la démarche de l’individu. Un algorithme est proposé pour segmenter le signal en cycles de marche. Dans une première approche, la démarche individuelle est représentée sous forme de paramètres spatiotemporels. Dans une seconde, elle est représentée sous la forme d’une unique séquence de quaternions unitaire appelée "Signature de Marche" (SdM). Des méthodes de classification non supervisée et semi-supervisée sont adaptées pour permettre d’identifier des groupes de patients présentant des déficits de la marche similaires à partir de leur SdM