Zhiling Li

Dr. Zhiling Li


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2022 in Sensors
Verified
Journal Article
Open access
PDF file
ZLZhiling Li
Zhiling Li
JYJianping Yin
Jianping Yin
GWGao Wang
Gao Wang
HLHaijian Liang
Haijian Liang
CZCongchun Zhang
Congchun Zhang
JZJie Zhang
Jie Zhang
This paper mainly studies the model design of a thin-film heat-flux sensor (TFHFS), and focuses on the comparison of three dynamic calibration methods. The primary motivation for studying this came from the urgent need for heat-flux dynamic measurements in extreme environments, and the one-sidedness of the dynamic performance evaluation of the corresponding TFHFS. The dynamic theoretical model of the TFHFS was originally established on the principle of a temperature gradient on the basis of a thermal radiation boundary. Then, a novel TFHFS sensor was developed, which can be used at temperatures above 880 °C and has a high sensitivity of 2.0 × 10−5 mV/(W/m2). It can function stably for long durations under a heat-flux density of 3 MW/m2. The steady-state, transient, and frequency calibration of a TFHFS were compared to comprehensively analyze the dynamic characteristics of the TFHFS. The steady-state response time measured by the step excitation method was found to be 0.978 s. The QR decomposition method was applied to the steady-state response experimental model construction, and the fitting degree of a second-order transfer function model obtained was 98.61%. Secondly, the transient response time of the TFHFS was 0.31 ms based on the pulse-excitation method. The transient relationship between the surface temperature and the heat flux, and the pulse-width dependence of the TFHFS transient response time were established. Surprisingly, the response frequency of the TFHFS, about 3000 Hz, was efficiently tested using the frequency response function (FRF), which benefitted from the harmonic characteristics of a periodic square-wave excitation signal. Finally, a comprehensive evaluation of the dynamic performance of the TFHFS was realized.

24 August 2023 in Electronics
Verified
Journal Article
Open access
PDF file
ZLZhiling Li
Zhiling Li
GWGao Wang
Gao Wang
JYJianping Yin
Jianping Yin
HXHongxin Xue
Hongxin Xue
JGJinqin Guo
Jinqin Guo
MHManguo Huang
Manguo Huang
Traditional contact heat flux sensors suffer from a lack of dynamic performance, and existing non-contact optical heat measurement equipment fails to detect convective heat transfer effectively. This limitation precludes the effective testing of composite heat flux in explosive fields. This study introduces an ultra-responsive atomic layer thermopile (ALTP) heat flux sensor, developed and employed for the first time, to evaluate the transient heat flux associated with thermobaric explosions. Measurements reveal that the ALTP sensor’s temporal resolution surpasses that of the thermal resistance thin film heat flux sensor (TFHF), attaining a spectral response time of 10 μs under pulsed laser irradiation. Beyond these radiation-based tests, the present work also conducted novel simulation analyses of high-temperature jet impacts using COMSOL software. Static simulation discovered that fluid velocity significantly influences ALTP’s sensitivity, resulting in an error of 71%. Conversely, dynamic simulation demonstrated that an increase in fluid velocity reduces the ALTP’s time constant, whereas other factors such as fluid temperature exert minimal impact on its dynamic characteristics. This confirms that the simulation model compensates for the cost and accuracy deficiencies of convection heating tests. It also provides a new way to analyze the error of explosive heat flux measurement caused by sensitivity fluctuation and insufficient dynamic performance. In thermobaric explosive trials, the maximum heat fluxes recorded were 202 kW/m2 in semi-enclosed environments and 526 kW/m2 in open environments. A distinctive double-wave phenomenon was evident in the test curve. By a fast-response thermocouple, the study was able to differentiate between radiation and convective heat flux in the explosion field. The findings substantiate that the ALTP sensor amalgamates the benefits of optical thermal measurement tools with those of traditional contact heat flux sensors, thereby facilitating composite heat flux measurements in the challenging conditions of an explosive field.

27 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
GWGao Wang
Gao Wang
CQChengyuan Qian
Chengyuan Qian
PSPeng Sun
Peng Sun
ZLZhiling Li
Zhiling Li
GCGuofeng Chen
Guofeng Chen
Junzhi YuJunzhi Yu
Junzhi Yu
In order to accurately detect the temperature of molten aluminum and overcome the adverse influence of high temperature and corrosiveness on the sensing results, a temperature detection system based on a multi-node sapphire fiber sensor was proposed and developed. Through the structural parameter design of the fiber sensor, the scheme of utilizing the 0.7 mm diameter fiber and 0.5 mm groove was formulated. Simulation and analysis were carried out to determine the ultrasonic response distribution of the signal passing through the whole fiber sensor. The results indicate that the system is capable of distinguishing test signals from various positions and temperatures. Following the completion of the static calibration, the temperature of the molten aluminum was observed in real-time, and the data of the temperature measurements conducted at the two groove locations were compared. According to the obtained results, the test accuracy was greater than 1 degree Celsius and the temperature test stability was good, laying a solid foundation for the potential development of temperature measurement devices.