Jong-jin Jeong

Dr. Jong-jin Jeong

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 September 2023 in Fire and Materials
Verified
Journal Article
Closed access
Kye-Won PARKKye-Won PARK
Kye-Won PARK
MMMasayuki Mizuno
Masayuki Mizuno
CCChang‐Geun Cho
Chang‐Geun Cho
JJJong-jin Jeong
Jong-jin Jeong

2 November 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Kye-Won PARKKye-Won PARK
Kye-Won PARK
MMMasayuki Mizuno
Masayuki Mizuno
CCChang-Geun Cho
Chang-Geun Cho
JJJong-jin Jeong
Jong-jin Jeong
The population density of cities has been increasing with time and the development of industry. Building fires in large cities with high population density cause extensive human and property damage. To prevent such damage, the characteristics of flames such as the thermal radiation and intensity of the fire source must be considered when designing building structures. However, the consideration of these factors is practically inadequate. Accordingly, in this study, when a mattress was ignited in an open environment at a different installation height (0–515 mm), the measurements from a heat flux meter and the calculated thermal radiation were compared, and a comparative analysis was conducted using the existing prediction formulas by researchers described in ISO 24678-7. We examined the fire risk of mattresses according to the mattress installation height. As a result, the fire risk of the mattress was confirmed according to the mattress installation height; upon comparing the experimental and calculated values for radiant heat, it was found to be necessary to estimate the radiant heat using a calculation method that applies the configuration factor differently depending on the change in the flame shape. In addition, as a result of substituting the experimental value into the calculation method of ISO 24678-7 (a method for estimating the radiant heat of liquid combustibles), the experimental value and the calculated value were found to be significantly different. Therefore, similar to ISO 24678-7 for the radiation heat estimation method for “liquid combustibles”, an international standard for establishing the radiation heat estimation method for “solid combustible materials” as a standard was also required for a reasonable analysis of the fire safety phenomenon of solid materials, such as bed mattresses.

3 December 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Kye-Won PARKKye-Won PARK
Kye-Won PARK
EJEun-Goo Jeon
Eun-Goo Jeon
JJJong-jin Jeong
Jong-jin Jeong
MKMoojoon Kim
Moojoon Kim
DKDo-Woo Kim
Do-Woo Kim
This study provides a comprehensive analysis of the fire hazards associated with Building-Integrated Photovoltaics (BIPV), using Aluminum Composite Panels (ACP) as a benchmark. Large-scale fire tests, modified from ISO 13785-1, were conducted on vertically installed BIPV modules to observe their fire behavior under conditions simulating a severe fire. The experimental process involved measuring key fire performance indicators, leading to the identification of a cascading failure mechanism. The BIPV modules demonstrated a peak Heat Release Rate (HRR) up to hi times higher (max. 898 kW) and smoke production nearly 10 times greater than the ACP baseline. The analysis reveals a distinct, multi-stage failure sequence that defines the systemic fire hazard of BIPV. Initially, a phenomenon strongly indicative of a chimney effect within the rear air cavity accelerates concealed fire spread. This rapid heating induces thermal stress, leading to extensive specimen damage termed cracking. This cracking event acts as a critical turning point, triggering a rapid release of trapped pyrolyzates and driving the fire to its peak intensity. This chain of events constitutes a unique hazard signature not observed in conventional cladding. The findings conclude that the fire risk of BIPV is a systemic issue, challenging the adequacy of component-level testing and highlighting the need for safety standards that assess the façade as a complete assembly.

24 May 2022 in Materials
Verified
Journal Article
Open access
PDF file
JJJong-jin Jeong
Jong-jin Jeong
MMMasayuki Mizuno
Masayuki Mizuno
Kye-Won PARKKye-Won PARK
Kye-Won PARK
HLHyeon-Jin Lim
Hyeon-Jin Lim
CCChang-Geun Cho
Chang-Geun Cho
Bed mattresses are rated as products to cause a fire hazard because of their very high heat release rate among indoor combustibles. In this study, fire growth rate and flame height were measured through a series of combustion experiments on a full scale in order to provide information regarding mattress fire characteristics. The experiments were conducted in an open space, and bed mattresses as the test samples were installed at different installation heights (0~515 mm). The experiment results revealed that the higher the bed mattress was installed, the higher the fire growth rate, the heat release rate, and the flame height. Additionally, the time of the mattress to reach 1 MW was evaluated as the category “medium” in the NFPA 72 standards. The flame heights showed a good coincidence compared to the existing flame height model equations, proving the applicability of the model to the mattress combustion.

12 April 2026 in Fire and Materials
Verified
Journal Article
Closed access
JJJong-jin Jeong
Jong-jin Jeong
MMMasayuki Mizuno
Masayuki Mizuno
Kye-Won PARKKye-Won PARK
Kye-Won PARK
CCChang‐Geun Cho
Chang‐Geun Cho