In this paper an analytical method based on high performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) for the determination of coumarin and its derivatives in tobacco products was developed. The MS/MS fragmentation pathways of the eight coumarins were elucidated. The new analytical method was defined based on two main axes, an extraction procedure with acetonitrile and analyte detection performed by HPLC-MS/MS in electron impact mode. The excellent selectivity and sensitivity achieved in multiple reaction monitoring (MRM) mode allowed satisfactory confirmation and quantitation for the coumarin flavor additives. Under the optimized gradient elution conditions, it took only 4.5 min to separate all eight coumarins. Good linearity for all the analytes were confirmed by the correlation coefficient r2, ranging from 0.9987 to 0.9996. The limits of detection (LODs) and limits of quantitation (LOQs) of these compounds were in the range of 0.5–1.7 μg/kg and 1.7–5.2 μg/kg, respectively. The average recoveries at three spiked levels (LOQ, 1.5LOQ, 2LOQ) were all in the range of 69.6%–95.1% with RSDs (n = 6) lower than 5.3%. The method of HPLC-MS/MS developed in this study was initially applied to the research of coumarin flavor additives in tobacco products collected from the located market in Beijing from China and proved to be accurate, sensitive, convenient and practical.
14 September 2022 in Journal of Agricultural and Food Chemistry
This paper presents an application of high performance liquid chromatography coupled with quadrupole orbitrap high-resolution mass spectrometry (HPLC-Q-Orbitrap HRMS) for the analysis of 27 β-blockers and metabolites in milk powder. Homogenized milk power samples were extracted by acetonitrile and purified by using Oasis PRiME HLB solid-phase extraction cartridges. The Ascentis® C8 chromatographic column was used to separate the analytes. The quantification was achieved by using matrix-matched standard calibration curves with carazolol-d7 and propranolol-d7 as the internal standards. The results show an exceptional linear relationship with the concentrations of analytes over wide concentration ranges (0.5–500 μg kg−1) as all the fitting coefficients of determination r2 are > 0.995. All the limits of detection (LODs) and quantitation (LOQs) values were within the respective range of 0.2–1.5 μg kg−1 and 0.5–5.0 μg kg−1. Overall average recoveries were able to reach 66.1–100.4% with the intra- and inter-day variability under 10%. This method has been successfully applied to the screening of β-blockers and metabolites in commercial milk powders. At the same time, the corresponding characteristic fragmentation behavior of the 27 compounds was explored. The characteristic product ions were determined and applied to the actual samples screening.