Background: Patient safety during anesthesia is crucially dependent on the monitoring of vital signs. However, the values obtained must also be perceived and correctly classified by the attending care providers. To facilitate these processes, we developed Visual-Patient-avatar, an animated virtual model of the monitored patient, which innovatively presents numerical and waveform data following user-centered design principles. After a high-fidelity simulation study, we analyzed the participants' perceptions of 3 different monitor modalities, including this newly introduced technique. Objective: The aim of this study was to collect and evaluate participants' opinions and experiences regarding 3 different monitor modalities, which are Visual-Patient-avatar, Split Screen (avatar and Conventional monitor alongside each other), and Conventional monitor after using them during simulated critical anesthetic events. Methods: This study was a researcher-initiated, single-center, semiquantitative study. We asked 92 care providers right after finishing 3 simulated emergency scenarios about their positive and negative opinions concerning the different monitor modalities. We processed the field notes obtained and derived the main categories and corresponding subthemes following qualitative research methods. Results: We gained a total of 307 statements. Through a context-based analysis, we identified the 3 main categories of "Visual-Patient-avatar," "Split Screen," and "Conventional monitor" and divided them into 11 positive and negative subthemes. We achieved substantial interrater reliability in assigning the statements to 1 of the topics. Most of the statements concerned the design and usability features of the avatar or the Split Screen mode. Conclusions: This study semiquantitatively reviewed the clinical applicability of the Visual-Patient-avatar technique in a high-fidelity simulation study and revealed the strengths and limitations of the avatar only and Split Screen modality. In addition to valuable suggestions for improving the design, the requirement for training prior to clinical implementation was emphasized. The responses to the Split Screen suggest that this symbiotic modality generates better situation awareness in combination with numerical data and accurate curves. As a subsequent development step, a real-life introduction study is planned, where we will test the avatar in Split Screen mode under actual clinical conditions.
Viscoelastic point-of-care haemostatic resuscitation methods, such as ROTEM or TEG, are crucial in deciding on time-efficient personalised coagulation interventions. International transfusion guidelines emphasise increased patient safety and reduced treatment costs. We analysed care providers’ perceptions of ROTEM to identify perceived strengths and areas for improvement. We conducted a single-centre, mixed qualitative–quantitative study consisting of interviews followed by an online survey. Using a template approach, we first identified themes in the responses given by care providers about ROTEM. Later, the participants rated six statements based on the identified themes on five-point Likert scales in an online questionnaire. Seventy-seven participants were interviewed, and 52 completed the online survey. By analysing user perceptions, we identified ten themes. The most common positive theme was “high accuracy”. The most common negative theme was “need for training”. In the online survey, 94% of participants agreed that monitoring the real-time ROTEM temograms helps to initiate targeted treatment more quickly and 81% agreed that recurrent ROTEM training would be beneficial. Anaesthesia care providers found ROTEM to be accurate and quickly available to support decision-making in dynamic and complex haemostatic situations. However, clinicians identified that interpreting ROTEM is a complex and cognitively demanding task that requires significant training needs.
As the interpretation of viscoelastic coagulation test results remains challenging, we created Visual Clot, an animated blood clot aiming to facilitate raw rotational thromboelastometry (ROTEM) parameters. This study investigated anesthesia personnel’s cognitive processing in managing simulated bleeding scenarios using eye-tracking technology. This multicenter, international, computer-based study across five large, central European hospitals included 35 participants with minimal to no prior experience interpreting viscoelastic test results. Using eye-tracking technology and an iPad tagged with quick response codes, we defined the time to treatment decision and the time on screen surface in seconds of correctly solved scenarios as our outcomes. The median time to treatment decision was 52 s for Visual Clot and 205 s for ROTEM (p < 0.0001). The probability of solving the scenario correctly was more than 8 times higher when using Visual Clot than when using ROTEM (Hazard ratio [HR] 8.54, 95% CI from 6.5 to 11.21; p < 0.0001). Out of 194 correctly answered scenarios of participants with the eye-tracker, 154 (79.4%) were solved with Visual Clot and 40 (20.6%) with ROTEM. Participants spent on average 30 s less looking at the screen surface with Visual Clot compared to ROTEM (Coefficient −30.74 s, 95% CI from −39.27 to −22.27; p < 0.0001). For a comparison of the two modalities in terms of information transfer, we calculated the percentage of time on the screen surface of the overall time to treatment decision, which with Visual Clot was 14 percentage points shorter than with ROTEM (Coefficient −14.55, 95% CI from −20.05 to −9.12; p < 0.0001). Visual Clot seems to improve perception and detection of coagulopathies and leads to earlier initiation of the appropriate treatment. In a high-pressure working environment such as the operating and the resuscitation room, correct and timely decisions regarding bleeding management may have a relevant impact on patients’ outcomes.
Patient monitoring is crucial in critical care medicine. Perceiving and interpreting multiple vital signs requires a high workload that can lead to decreased situation awareness and consequently inattentional blindness, defined as impaired perception of unexpectedly changing data. To facilitate information transfer, we developed and validated the Visual-Patient avatar. Generated by numerical data, the animation displays the status of vital signs and patient installations according to a user-centered design to improve situation awareness. As a surrogate parameter for information transfer in patient monitoring, we recorded visual attention using eye-tracking data. In this computer-based study, we compared the correlation of visually perceived and correctly interpreted vital signs between a Visual-Patient-avatar ICU and conventional patient monitoring. A total of 50 recruited study participants (25 nurses, 25 physicians) from five European study centers completed five randomized scenarios in both modalities. Using a stationary eye tracker as the primary endpoint, we recorded how long different areas of interest of the two monitoring modalities were viewed. In addition, we tested for a possible association between the length of time an area of interest was viewed and the correctness of the corresponding question. With the conventional monitor, participants looked at the installation site the longest (median 2.13–2.51 s). With the Visual-Patient-avatar ICU, gaze distribution was balanced; no area of interest was viewed for particularly long. For both modalities, the longer an area was viewed, the more likely the associated question was answered incorrectly (OR 0.97, 95% CI 0.95–0.99, p = 0.008). The Visual-Patient-avatar ICU facilitates and improves information transfer through its visualizations, especially with written information. The longer an area of interest was viewed, the more likely the associated question was answered incorrectly.
Interpreting blood gas analysis results can be challenging for the clinician, especially in stressful situations under time pressure. To foster fast and correct interpretation of blood gas results, we developed Visual Blood. This computer-based, multicentre, noninferiority study compared Visual Blood and conventional arterial blood gas (ABG) printouts. We presented six scenarios to anaesthesiologists, once with Visual Blood and once with the conventional ABG printout. The primary outcome was ABG parameter perception. The secondary outcomes included correct clinical diagnoses, perceived diagnostic confidence, and perceived workload. To analyse the results, we used mixed models and matched odds ratios. Analysing 300 within-subject cases, we showed noninferiority of Visual Blood compared to ABG printouts concerning the rate of correctly perceived ABG parameters (rate ratio, 0.96; 95% CI, 0.92–1.00; p = 0.06). Additionally, the study revealed two times higher odds of making the correct clinical diagnosis using Visual Blood (OR, 2.16; 95% CI, 1.42–3.29; p < 0.001) than using ABG printouts. There was no or, respectively, weak evidence for a difference in diagnostic confidence (OR, 0.84; 95% CI, 0.58–1.21; p = 0.34) and perceived workload (Coefficient, 2.44; 95% CI, −0.09–4.98; p = 0.06). This study showed that participants did not perceive the ABG parameters better, but using Visual Blood resulted in more correct clinical diagnoses than using conventional ABG printouts. This suggests that Visual Blood allows for a higher level of situation awareness beyond individual parameters’ perception. However, the study also highlighted the limitations of today’s virtual reality headsets and Visual Blood.
Visual Patient Avatar ICU is an innovative approach to patient monitoring, enhancing the user’s situation awareness in intensive care settings. It dynamically displays the patient’s current vital signs using changes in color, shape, and animation. The technology can also indicate patient-inserted devices, such as arterial lines, central lines, and urinary catheters, along with their insertion locations. We conducted an international, multi-center study using a sequential qualitative-quantitative design to evaluate users’ perception of Visual Patient Avatar ICU among physicians and nurses. Twenty-five nurses and twenty-five physicians from the ICU participated in the structured interviews. Forty of them completed the online survey. Overall, ICU professionals expressed a positive outlook on Visual Patient Avatar ICU. They described Visual Patient Avatar ICU as a simple and intuitive tool that improved information retention and facilitated problem identification. However, a subset of participants expressed concerns about potential information overload and a sense of incompleteness due to missing exact numerical values. These findings provide valuable insights into user perceptions of Visual Patient Avatar ICU and encourage further technology development before clinical implementation.