Olga Sorokia

Dr. Olga Sorokia


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 April 2012 in Applied Sciences
Verified
Journal Article
Open access
PDF file
OSOlga Sorokia
Olga Sorokia
AKAlexander L. Kovarski
Alexander L. Kovarski
MLMarina A. Lagutina
Marina A. Lagutina
SDSergey A. Dubrovskii
Sergey A. Dubrovskii
FDFridrikh S. Dzheparov
Fridrikh S. Dzheparov
Aggregation of magnetic nanoparticles immobilized in polymer gels was studied by ferromagnetic resonance and paramagnetic sensor techniques. Ferromagnetic resonance spectra of magnetic gels prepared in the presence of external magnetic field of 1.5 kG were compared to the spectra of gels synthesized in the absence of a magnetic field. Application of a magnetic field led to formation of linear aggregates of magnetic particles in the polymer matrix. The aggregates did not come apart after the field was switched off. The fraction of aggregated particles (of 62(6)%) and aspect ratio (elongation) of the aggregates (12.6(1.3)) was determined using paramagnetic sensor technique.

14 September 2020 in Microchimica Acta
Verified
Journal Article
Closed access
PDF file
SPSergey N. Podoynitsyn
Sergey N. Podoynitsyn
OSOlga Sorokia
Olga Sorokia
NNNatalia L. Nechaeva
Natalia L. Nechaeva
SYSergey V. Yanovich
Sergey V. Yanovich
IKIlya N. Kurochkin
Ilya N. Kurochkin

27 February 2019 in Separation Science Plus
Verified
Journal Article
Open access
PDF file
SPSergey N. Podoynitsyn
Sergey N. Podoynitsyn
OSOlga Sorokia
Olga Sorokia
MKMaksim A. Klimov
Maksim A. Klimov
ILIgor I. Levin
Igor I. Levin
SSSergey B. Simakin
Sergey B. Simakin
Barrier contactless dielectrophoresis is proposed as a method for microbiological particle separation. Design of a separation device for barrier contactless dielectrophoresis is discussed. The principle of separation device is based on formation of barriers of gradient fields in the volume of separation chamber by electrodes with passivation dielectric coating of silicon carbide. A feature of the method is absence of contact between separated samples and conductive elements of electrode structure. The proposed method is highly efficient and easy to use in comparison with dielectrophoresis on isolated structures and conventional planar systems. Computer simulation of electric field distribution over dielectrophoretic barriers is carried out, and effect of the thickness of the passivation coating on dielectrophoretic properties of barriers is shown. Forces acting on a particle (a yeast cell with a diameter of 7 μm) in separation chamber are evaluated using computer simulation data. Ability of the cell to be captured by the method of contactless barrier dielectrophoresis is theoretically predicted and confirmed experimentally, using yeast cells. The yeast cells subjected to positive dielectrophoresis can be effectively captured (up to 90%) by the separation device at the applied voltage of 20 V and 100 kHz and at flow rate of 20 mL/h.

1 December 2024 in Russian Journal of Physical Chemistry B
Verified
Journal Article
Closed access
PDF file
OSOlga Sorokia
Olga Sorokia
TKT. S. Konstantinova
T. S. Konstantinova
AVA. K. Vorobyova
A. K. Vorobyova
AVA. D. Vasilyeva
A. D. Vasilyeva
LYL. V. Yurina
L. V. Yurina
IKI. N. Kurochkin
I. N. Kurochkin
A highly sensitive method for the quantitative rapid determination of cardiac troponin I (cTnI) in human serum is developed. The method is based on an enzyme-linked immunosorbent assay (ELISA) on magnetic particles in the volume of a blood serum sample, which can significantly reduce the diffusion limitations typical for the traditional ELISA. Alkaline phosphatase which is a high-performance enzyme was used as an enzyme label. The enzyme demonstrated a catalytic efficiency of (kcat/Km) = 26 500 L/(s mM) in combination with the substrate 1-naphtyl phosphate monosodium salt. The planar electrochemical sensors manufactured by industrial screen-printing technology are used for signal detection. The detection is carried out in differential pulse voltammetry mode. The calculated limit of detection by the enzymatic reaction product is 0.075 μM which significantly exceeds the sensitivity of colorimetric methods. The combination of the proposed methods and approaches makes it possible to obtain a quantitative analysis for cTnI in human serum within 20 min with an estimated detection limit of 7 pg/mL and the upper reference limit of the normal analyte concentration (99th percentile) of 22 pg/mL.

1 January 2017 in Biotekhnologiya
Verified
Journal Article
Closed access
SPS.N. Podoynitsyn
S.N. Podoynitsyn
OSOlga Sorokia
Olga Sorokia
MKM.A. Klimov
M.A. Klimov
PPPavel Pronkin
Pavel Pronkin
OBO.A. Bozhkova
O.A. Bozhkova
AKA.L. Kovarski
A.L. Kovarski

18 January 2026 in Talanta
Verified
Journal Article
Closed access
KPKirill Prusakov
Kirill Prusakov
KAKonstantin G. Aldarov
Konstantin G. Aldarov
OSOlga Sorokia
Olga Sorokia
TKTatyana S. Konstantinova
Tatyana S. Konstantinova
AVAnastasia K. Vorobyova
Anastasia K. Vorobyova
IKIliya N. Kurochkin
Iliya N. Kurochkin