Juan Manuel Belda Lois

Dr. Juan Manuel Belda Lois

Instituto de Biomecánica de Valencia, Universitat Politècnica de València, 46022 Valencia, Spain
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2011 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
Juan Manuel Belda LoisJuan Manuel Belda Lois
Juan Manuel Belda Lois
SHSilvia Mena-Del Horno
Silvia Mena-Del Horno
IBIgnacio Bermejo-Bosch
Ignacio Bermejo-Bosch
JMJuan C. Moreno
Juan C. Moreno
JPJose L. Pons
Jose L. Pons
MRMassimiliano Rea
Massimiliano Rea
This document provides a review of the techniques and therapies used in gait rehabilitation after stroke. It also examines the possible benefits of including assistive robotic devices and brain-computer interfaces in this field, according to a top-down approach, in which rehabilitation is driven by neural plasticity.The methods reviewed comprise classical gait rehabilitation techniques (neurophysiological and motor learning approaches), functional electrical stimulation (FES), robotic devices, and brain-computer interfaces (BCI).From the analysis of these approaches, we can draw the following conclusions. Regarding classical rehabilitation techniques, there is insufficient evidence to state that a particular approach is more effective in promoting gait recovery than other. Combination of different rehabilitation strategies seems to be more effective than over-ground gait training alone. Robotic devices need further research to show their suitability for walking training and their effects on over-ground gait. The use of FES combined with different walking retraining strategies has shown to result in improvements in hemiplegic gait. Reports on non-invasive BCIs for stroke recovery are limited to the rehabilitation of upper limbs; however, some works suggest that there might be a common mechanism which influences upper and lower limb recovery simultaneously, independently of the limb chosen for the rehabilitation therapy. Functional near infrared spectroscopy (fNIRS) enables researchers to detect signals from specific regions of the cortex during performance of motor activities for the development of future BCIs. Future research would make possible to analyze the impact of rehabilitation on brain plasticity, in order to adapt treatment resources to meet the needs of each patient and to optimize the recovery process.

17 September 2007 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
EREduardo Rocon
Eduardo Rocon
Juan Manuel Belda LoisJuan Manuel Belda Lois
Juan Manuel Belda Lois
ARAndres Ruiz-Olaya
Andres Ruiz-Olaya
MMM. Manto
M. Manto
JMJuan C. Moreno
Juan C. Moreno
JPJose L. Pons
Jose L. Pons
Exoskeletons are mechatronic systems worn by a person in such a way that the physical interface permits a direct transfer of mechanical power and exchange of information. Upper limb robotic exoskeletons may be helpful for people with disabilities and/or limb weakness or injury. Tremor is the most common movement disorder in neurological practice. In addition to medication, rehabilitation programs, and deep brain stimulation, biomechanical loading has appeared as a potential tremor suppression alternative. This paper introduces the robotic exoskeleton called WOTAS (wearable orthosis for tremor assessment and suppression) that provides a means of testing and validating nongrounded control strategies for orthotic tremor suppression. This paper describes in detail the general concept for WOTAS, outlining the special features of the design and selection of system components. Two control strategies developed for tremor suppression with exoskeletons are described. These two strategies are based on biomechanical loading and notch Altering the tremor through the application of internal forces. Results from experiments using these two strategies on patients with tremor are summarized. Finally, results from clinical trials are presented, which indicate the feasibility of ambulatory mechanical

1 September 2020 in Applied Ergonomics
Verified
Journal Article
Closed access
Sofía IranzoSofía Iranzo
Sofía Iranzo
APAlicia Piedrabuena
Alicia Piedrabuena
DIDaniel Iordanov
Daniel Iordanov
UMUrsula Martinez-Iranzo
Ursula Martinez-Iranzo
Juan Manuel Belda LoisJuan Manuel Belda Lois
Juan Manuel Belda Lois

1 May 2017 in Robotics and Autonomous Systems
Verified
Journal Article
Open access
CBCristina Bayón
Cristina Bayón
ORO. Ramírez
O. Ramírez
José Ignacio SerranoJosé Ignacio Serrano
José Ignacio Serrano
María Dolores MesaMaría Dolores Mesa
María Dolores Mesa
APA. Pérez-Somarriba
A. Pérez-Somarriba
EREduardo Rocon
Eduardo Rocon
The term Cerebral Palsy (CP) is a set of neurological disorders that appear in infancy or early childhood and permanently affect body movement and muscle coordination. The prevalence of CP is twothree per 1000 births. Emerging rehabilitation therapies through new strategies are needed to diminish the assistance required for these patients, promoting their functional capability. This paper presents a new robotic platform called CPWalker for gait rehabilitation in patients with CP, which allows them to start experiencing autonomous locomotion through novel robot-based therapies. The platform (smart walker +exoskeleton) is controlled by a multimodal interface that gives high versatility. The therapeutic approach, as well as the details of the interactions may be defined through this interface. CPWalker concept aims to promote the earlier incorporation of patients with CP to the rehabilitation treatment and increases the level of intensity and frequency of the exercises. This will enable the maintenance of therapeutic methods on a daily basis, with the intention of leading to significant improvements in the treatment outcomes. Rehabilitation with free displacement and not restricted to a treadmill.Integration of central nervous system into therapies.Postural control and partial body weight support for individuals with more severe disorders.Assist as needed approach.Locomotion strategy based on laser sensor.

1 January 2013 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
JGJuan Alvaro Gallego
Juan Alvaro Gallego
EREduardo Rocon
Eduardo Rocon
Juan Manuel Belda LoisJuan Manuel Belda Lois
Juan Manuel Belda Lois
JPJose L. Pons
Jose L. Pons
Pathological tremor is the most prevalent movement disorder. Current treatments do not attain a significant tremor reduction in a large proportion of patients, which makes tremor a major cause of loss of quality of life. For instance, according to some estimates, 65% of those suffering from upper limb tremor report serious difficulties during daily living. Therefore, novel forms for tremor management are required. Since muscles intrinsically behave as a low pass filter, and tremor frequency is above that of volitional movements, the authors envisioned the exploitation of these properties as a means of developing a novel treatment alternative. This treatment would rely on muscle co-contraction for tremor management, similarly to the strategy employed by the intact central nervous system to stabilize a limb during certain tasks. We implemented a neuroprosthesis that regulated the level of muscle co-contraction by injecting current at a pair of antagonists through transcutaneous neurostimulation. Co-contraction was adapted to the instantaneous parameters of tremor, which were estimated from the raw recordings of a pair of solid state gyroscopes with a purposely designed adaptive algorithm. For the experimental validation, we enrolled six patients suffering from parkinsonian or essential tremor of different severity, and evaluated the effect of the neuroprosthesis during standard tasks employed for neurological examination. The neuroprosthesis attained significant attenuation of tremor (p<0.001), and reduced its amplitude up to a 52.33±25.48%. Furthermore, it alleviated both essential and parkinsonian tremor in spite of their different etiology and symptomatology. Tremor severity was not a limiting factor on the performance of the neuroprosthesis, although there was a subtle trend towards larger attenuation of more severe tremors. Tremor frequency was not altered during neurostimulation, as expected from the central origin of Parkinson’s disease and essential tremor. All patients showed a good tolerance to neurostimulation in terms of comfort and absence of pain, and some spontaneously reported that they felt that tremor was reduced when the neuroprosthesis was activated. The results presented herein demonstrate that the neuroprosthesis provides systematic attenuation of the two major types of tremor, irrespectively from their severity. This study sets the basis for the validation of the neuroprosthesis as an alternative, non-invasive means for tremor management.

19 July 2004 in Technology and Disability
Verified
Journal Article
Closed access
PDF file
EREduardo Rocon
Eduardo Rocon
Juan Manuel Belda LoisJuan Manuel Belda Lois
Juan Manuel Belda Lois
JSJ.J. Sanchez-Lacuesta
J.J. Sanchez-Lacuesta
JPJose L. Pons
Jose L. Pons
A great deal of effort has been devoted in the past decades in the generic area of tremor management. Specific topics of modelling for objective classification of pathological tremor out of kinematics and physiological data, compensatory technologies