We propose an efficient direct k-domain interpolation based on spectral phase in swept-source optical coherence tomography (SS-OCT). Both the calibration signal from the Mach-Zehnder interferometer (MZI) and the OCT imaging signal from the Michelson interferometer sharing the same swept source are detected and digitized simultaneously. Sufficient sampling of the OCT imaging signal with uniform k interval are directly interpolated in the k-domain based on the spectral phase derived from MZI calibration signal. Depth profile is then obtained from Fourier transform of the k-domain interpolated data. In vivo imaging of human finger skin and nail fold are conducted. Reconstructed images corresponding to different calibration methods are evaluated for comparison. Experimental results demonstrate that improved imaging quality with enhanced resolution and signal-to-noise ratio is realized by the proposed method in contrast to the spectral phase based time-domain interpolation method as well as the intensity based calibration method.
We present a miniaturized precalibration-based forward-viewing Lissajous scanning fiber probe for high speed endoscopic optical coherence tomography (OCT). The probe is based on an asymmetric fiber cantilever driven by the piezoelectric bender to realize two-dimensional (2D) Lissajous scanning. The stability and repeatability of the Lissajous scanning trajectory of the probe is tested by a position sensitive detector (PSD)-based position calibration setup. The two orthogonal resonant frequencies of the cantilever are measured to be 167.2 and 121 Hz. A 25 µm focal spot is formed at the working distance of 5 mm by the graded-index (GRIN) lens, and the field of view of the imaging probe is around . The probe is fully packaged in a hypodermic tube for endoscopic imaging. The total rigid length and outer diameter are 35 mm and 3.5 mm, respectively. The probe is incorporated in a 50 KHz swept source OCT system with the axial resolution of 14 µm, and its imaging performance is validated by the 2D en face and 3D volumetric OCT imaging of the phantom and the biological tissue.
An adaptive total variation method based on the combination of speckle statistics and total variation restoration is proposed and developed for reducing speckle noise in optical coherence tomography (OCT) images. The statistical distribution of the speckle noise in OCT image is investigated and measured. With the measured parameters such as the mean value and variance of the speckle noise, the OCT image is restored by the adaptive total variation restoration method. The adaptive total variation restoration algorithm was applied to the OCT images of a volunteer’s hand skin, which showed effective speckle noise reduction and image quality improvement. For image quality comparison, the commonly used median filtering method was also applied to the same images to reduce the speckle noise. The measured results demonstrate the superior performance of the adaptive total variation restoration method in terms of image signal-to-noise ratio, equivalent number of looks, contrast-to-noise ratio, and mean square error.
We present a spatial frequency domain multiplexing method for extending the imaging depth range of a spectral domain optical coherence tomography (SDOCT) system without any expensive device. This method uses two galvo scanners with different pivot-offset distances in two independent reference arms for spatial frequency modulation and multiplexing. The spatial frequency contents corresponding to different depth regions of the sample can be shifted to different frequency bands. The spatial frequency domain multiplexing SDOCT system provides an approximately 1.9-fold increase in the effective ranging depth compared with that of a conventional full-range SDOCT system. The reconstructed images of phantom and biological tissue demonstrate the expected increase in ranging depth. The parameters choice criterion for this method is discussed.
In spectraldomain optical coherence tomography the sample is illuminated by a broadband light source, and the spectrum of the interference light between the light returned from the sample and a reference mirror is detected by a grating spectrometer. Conventionally, the grating spectrometer is comprised of a diffraction grating, a focusing lens, and a line-scan camera. According to the grating equation the diffraction angle from the grating is approximately linearly related to the optical wavelength. Thus the distribution function of the light spectrum at the line-scan camera is nonlinearly dependent on wavenumber. For the high-quality image reconstruction, the numerical resampling of the spectral interference data from wavelength-space to wavenumber-space is commonly required prior to the Fourier Transformation. The nonlinear detection of the spectral interferograms in wavenumber space also degrades the depth-dependent signal sensitivity in conventional linear-wavelength spectrometer based spectraldomain optical coherence tomography. Recently reported spectraldomain optical coherence tomography based on a linearwavenumber spectrometer does not need the resampling or interpolating of the nonlinearwavenumber interference spectral data, which greatly reduces the cost of computation and improves the imaging sensitivity. Various methods based on the different evaluation protocols for optimizing the design of the linear-wavenumber spectrometer have been reported. Here we report an effective optimization method for linear-wavenumber spectrometer used in a high-resolution spectral domain optical coherence tomography system. We take the reciprocal of the fullwidthhalfmaximum of the simulated point spread function as an evaluating criterion to optimize the structure parameters of the linearwavenumber spectrometer, including the refractive index and the vertex angle of the dispersive prism and the rotation angle between the diffraction grating and the dispersive prism. According to the optimization, an F2 equilateral dispersive prism is used to construct the optimized linearwavenumber spectrometer with a rotation angle of 21.8°. We construct an optimized linearwavenumber spectrometer and implement the spectrometer in a developed spectraldomain optical coherence tomography system as a detection unit. We evaluate the performances of the linear-wavenumber spectrometer both theoretically and experimentally. The experimentally measured axial resolution of the spectraldomain optical coherence tomography system based on the linear-wavenumber spectrometer is 8.52 μm, and the sensitivity is measured to be 91 dB with -6 dB sensitivity roll-off within a depth range of 1.2 mm. The experimentally measured sensitivity roll-off curve accords well with the theoretical sensitivity roll-off curve. Utilizing the general parallel computing capability of a GPU card, the highquality spectraldomain optical coherence tomography images of the human finger skin can be reconstructed in real time without any resampling or interpolating process.
To realize the high sensitivity polarization sensitive optical coherence tomography (PS-OCT) imaging, a fiber-based full-range depth-encoded swept source PS-OCT (SS-PS-OCT) method is proposed. The two OCT images corresponding to the orthogonal polarized input light are located on the high sensitivity imaging region of the opposite sides relative to the zero optical path difference position. The full-range OCT images can be obtained by implementing the spatial phase modulation in the reference arm. The detection sensitivity of the system was measured experimentally to be 67 dB when the imaging depth approaching to 2 mm. The imaging of the biological tissue verifies that the proposed full-range depth-encoded SS-PS-OCT system has the higher detection sensitivity compared with the conventional depth encoded SS-PS-OCT system. Finally, we demonstrated the full-range high sensitivity phase retardation image of the bovine tendon and skin of human fingertip. The fiber-based full-range depth-encoded SS-PS-OCT method can realize the high sensitivity birefringence imaging in the medical diagnosis scenes with the requirements for long imaging range and high detection sensitivity.