Acacio Manuel Amaral

Prof. Acacio Manuel Amaral

Polytechnic Institute of Coimbra, Coimbra, Portugal
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2009 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Acacio Manuel AmaralAcacio Manuel Amaral
Acacio Manuel Amaral
Antonio J. Marques CardosoAntonio J. Marques Cardoso
Antonio J. Marques Cardoso
This paper presents a very simple technique to estimate the condition of aluminum-electrolytic-capacitors. The aging of aluminum-electrolytic-capacitors is expressed by the increase of their equivalent series resistance (ESR) and the reduction of their capacitance. Thus, the proposed technique is based on the estimation of both the ESR and capacitance values. To implement the proposed technique, the capacitor is fed by a sinusoidal voltage with the required power. The resultant impedance vector defined by the capacitor voltage and current gives enough information to estimate the condition of the capacitor.

7 March 2012 in IET Power Electronics
Verified
Journal Article
Closed access
Acacio Manuel AmaralAcacio Manuel Amaral
Acacio Manuel Amaral
Antonio J. Marques CardosoAntonio J. Marques Cardoso
Antonio J. Marques Cardoso
The aim of this study is to present a simple on-line fault detection technique that is able to prevent structural failures in aluminium electrolytic capacitors used in the output filter of step-down DC–DC converters. The aluminium electrolytic capacitors equivalent circuit consists of an ideal resistance in series with an ideal capacitor and an ideal inductor. The first two elements change with frequency, temperature and aging. Most manufacturers define the end of life limit of these capacitors when their internal resistance (equivalent series resistance (ESR)) doubles or their capacitance (C) reduces by 20%, when compared with the initial values. The proposed on-line fault detection technique is able to estimate the capacitor ESR value during converter operation. For that purpose, a simple relationship between the input current and the output voltage ripple is used. The measurement system is composed of a digital oscilloscope that is connected to a microcomputer with ‘Matlab’ software. Several simulation and experimental results are presented to validate the proposed fault detection technique.

20 October 2009 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
GBGustavo Malagoni Buiatti
Gustavo Malagoni Buiatti
JMJ A Martín-Ramos
J A Martín-Ramos
CGCarlos H. Rojas Garcia
Carlos H. Rojas Garcia
Acacio Manuel AmaralAcacio Manuel Amaral
Acacio Manuel Amaral
Antonio J. Marques CardosoAntonio J. Marques Cardoso
Antonio J. Marques Cardoso
Capacitors usually determine the overall lifetime of power converters since they are mainly responsible for breakdowns. Their failure results from the deterioration of their dielectric, the production of gases, and, eventually, their explosion. This process leads to an increase in the capacitor equivalent series resistance (ESR) and a decrease in its capacitance value for both electrolytic and metalized polypropylene film (MPPF) capacitors. In this paper, a novel noninvasive technique for capacitor diagnostic in Boost converters is presented. It can easily be applied online and even in real time, and it is suitable for the operation in both continuous current mode (CCM) and discontinuous current mode (DCM). The technique is based on the double estimations of the ESR and the capacitance, improving the diagnostic reliability. This way, predictive maintenance is provided, and it is possible to alarm for capacitor replacement, avoiding downtime. As the method is intended for railway high-power applications, it has been conceived neither to add any additional hardware in the power stage nor to even slightly modify it. To demonstrate and validate the effectiveness and accuracy of the proposed technique, several simulations and experimental results are discussed in a small prototype. In this prototype, the software for real-time estimation is programmed in a low-cost digital signal processor (DSP).

5 April 2010 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Acacio Manuel AmaralAcacio Manuel Amaral
Acacio Manuel Amaral
Antonio J. Marques CardosoAntonio J. Marques Cardoso
Antonio J. Marques Cardoso
The aim of this paper is to present two very simple, cheap, and practical experimental techniques that are able to estimate the capacitor equivalent circuit for a wide range of frequencies and temperatures. The capacitor equivalent circuit considerably changes with temperature, aging, and frequency. Therefore, knowledge of their equivalent circuit at their operating conditions can lead to better design proposals. In addition, knowledge of the evolution of the equivalent series resistance (ESR) with temperature is essential for the development of reliable online fault diagnosis techniques. This issue is particularly important for aluminum electrolytic capacitors, since they are the preferred capacitor type in power electronics applications and simultaneously one of the most critical components in such applications. To implement the first technique, it is necessary to put the capacitor under test in series with a resistor and connect it to a sinusoidal voltage. The second technique requires a simple charge-discharge circuit. After acquiring both capacitors' current and voltage through an oscilloscope, which is connected to a PC with Matlab software, it is possible to compute both capacitor capacitance and resistance using the least mean square (LMS) algorithm. To simulate the variation of capacitor case temperature, a very simple prototype was used. Several experimental results were obtained to evaluate the accuracy and precision of the two experimental techniques.

4 August 2009 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
GBGustavo Malagoni Buiatti
Gustavo Malagoni Buiatti
JMJuan A. Martín-Ramos
Juan A. Martín-Ramos
Acacio Manuel AmaralAcacio Manuel Amaral
Acacio Manuel Amaral
PDPiotr Dworakowski
Piotr Dworakowski
Antonio J. Marques CardosoAntonio J. Marques Cardoso
Antonio J. Marques Cardoso
A novel technique for monitoring the condition of metallized polypropylene film (MPPF) capacitors installed in the dc link of railway power trains is proposed in this paper. The technique is based on the capacitance estimation of the two different capacitors used in the dc link (dc filtering and 2F filter capacitors), and it is done without adding any extra sensor or filter to the respective traction drive scheme. Therefore, the proposed method is implemented using software but not additional hardware for the different trains. Two other important passive component parameters of the traction drive are also monitored, all of them by means of curve fitting based on the least-mean-square (LMS) algorithm. The proposed technique is implemented and validated at simulation and experimental levels, using MATLAB/Simulink and a 1.2-MW traction drive test bench. Very accurate results are obtained, and the predictive maintenance of MPPF capacitors for different topologies of railway power trains can be set through the proposed technique.

17 June 2008 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Acacio Manuel AmaralAcacio Manuel Amaral
Acacio Manuel Amaral
Antonio J. Marques CardosoAntonio J. Marques Cardoso
Antonio J. Marques Cardoso
This paper presents an experimental technique that allows the determination of both reactance and equivalent series resistance (ESR) intrinsic values of aluminum electrolytic capacitors. The ESR is one of the most critical problems of static converters that operate near the resonance frequency of electrolytic capacitors. An increased ESR value leads to a significant increase in the alternate component of the output voltage, requiring constant action of the control system. In addition, manufacturers usually do not give the ESR value, but do give the maximum dissipation factor (DF), at the operating frequency of 120 Hz. From the DF, it is possible to determine the maximum ESR value at 120 Hz. Since the ESR value changes with frequency, and static converters operate at much higher ranges, designers need to compute its value at the operating frequency of these converters to reach the best design proposal. Moreover, almost all capacitor manufacturers give the capacitance value with a tolerance of 20%, whereas the proposed technique permits computation of its value with higher accuracy. Additionally, at low frequencies, if the ESR value of the capacitor is known, through its comparison with the maximum value given by the manufacturer, it is possible to estimate its condition. To validate the proposed technique and to demonstrate its applicability, some experimental results are presented and compared with the ones obtained with an impedance gain-phase analyzer and the manufacturers' specifications for four different capacitors.