Administration of a selective β1-blocker, such as esmolol, in human septic shock has demonstrated cardiovascular protective effects related to heart rate reduction. Certain experimental data also indicate that esmolol exerts systemic anti-inflammatory and beneficial effects on vascular tone. Thus, the present study aimed to determine whether a non-chronotropic dose of esmolol maintains its protective cardiovascular and anti-inflammatory effects in experimental septic shock. Four hours after cecal ligation and puncture (CLP), Wistar male rats were randomly allocated to the following groups (n = 8): CLP, CLP + E-1 (esmolol: 1 mg.kg−1.h−1), CLP + E-5 (esmolol: 5 mg.kg−1.h−1), CLP + E-18 (esmolol: 18 mg.kg−1.h−1). An additional eight rats underwent sham operation. All rats received a continuous infusion of saline, analgesic and antibiotics 4 hours after the surgery. Assessment at 18 hours included in vivo cardiac function assessed by echocardiography and ex vivo vasoreactivity assessed by myography. Circulating cytokine levels (IL-6 and IL-10) were measured by ELISA. Cardiac and vascular protein expressions of p-NF-κB, IκBα, iNOS, p-AKT/AKT and p-eNOS/eNOS were assessed by western blotting. CLP induced tachycardia, hypotension, cardiac output reduction, hyperlactatemia and vascular hypo-responsiveness to vasopressors. Compared to CLP animals, heart rate was unchanged in CLP + E-1 and CLP + E-5 but was reduced in CLP + E-18. Stroke volume, cardiac output, mean arterial pressure and lactatemia were improved in CLP + E-1 and CLP + E-5, while vascular responsiveness to phenylephrine was only improved in CLP + E-5 and CLP + E-18. Plasma IL-6 levels were decreased in all esmolol groups. p-NF-κB was decreased in both cardiac and vascular tissues in CLP + E-5 and CLP + E-18. In experimental septic shock, low doses of esmolol still improved cardiac function and vasoreactivity. These benefits appear to be associated with a modulation of inflammatory pathways.
Remote photoplethysmography imaging (rPPG) is a new solution proposed to measure vital signs, such as respiratory rate (RR) in teleconsultation, by using a webcam. The results, presented here, aim at evaluating the accuracy of such remote measurement methods, compared with existing measurement methods, in a real-life clinical setting. For each patient, measurement of RR, using the standard system (control), has been carried out concomitantly with the experimental system. A 60-s time frame was used for the measurements made by our rPPG system. Age, gender, BMI, and skin phototype were collected. We performed the intraclass correlation coefficient and Bland–Altman plot to analyze the accuracy and precision of the rPPG algorithm readings. Measurements of RR, using the two methods, have been realized on 963 patients. Comparison of the two techniques showed excellent agreement (96.0%), with most of the patients (n = 924—standard patients) being in the confidence interval of 95% in Bland–Altman plotting. There were no significant differences between standard patients and outlier patients for demographic and clinical characteristics. This study indicates a good agreement between the rPPG system and the control, thus allowing clinical use of this remote assessment of the respiratory rate.
1 January 2021 in Journal of Gynecology Obstetrics and Human Reproduction
Introduction: Physiological signals are essential for assessing human health. The absence of a medical device to carry out these measurements remotely is one of the main limitations of telemedicine. Remote photoplethysmography imaging (rPPG) makes it possible to use a camera video to measure some of the most valuable physiological variables: heart rate (HR), respiratory rate (RR) and oxygen saturation (SpO 2 ). Our objective was to evaluate the value of such remote measurements compared with existing contact point measurements techniques in real-life clinical settings. Methods and analysis: Prospective hospital-based study that will recruit 1045 patients who require a pulmonary function test. For each patient, measurements of HR, RR and SpO 2 , using a standard acquisition system, will be carried out concomitantly with the measurements made by the rPPG system. 30, 60 and 120 s time frames will be used to take measurements. Age, gender and skin phototype will also be collected. The intraclass coefficient correlation will be performed to determine the accuracy and precision of the rPPG algorithm readings. Ethics and dissemination: The study protocol has been approved by the French Agency for the Safety of Health Products (ANSM registration no. ID RCB 2020-A02428-31) and by a French ethics committee (CPP OUEST I-TOURS-2020T1-30 DM at 30 October 2020). Results will be published in peer-reviewed journals, at scientific conferences and through press releases. Trial registration number: NCT04660318 .