Mohammad Saleh Salmanpour

Mr. Mohammad Saleh Salmanpour


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2016 in Journal of Intelligent Material Systems and Structures
Verified
Journal Article
Open access
PDF file
MSMohammad Saleh Salmanpour
Mohammad Saleh Salmanpour
ZZahra Sharif Khodaei
Zahra Sharif Khodaei
MAMh Aliabadi
Mh Aliabadi
In this article, a method for addressing temperature effects using Lamb waves is developed with application to baseline comparison damage detection. The proposed method is based on baseline signal stretch with an improved minimum residual allowing correction over a larger temperature range. The effectiveness of the proposed approach in detecting (artificial) damages is demonstrated experimentally over a large temperature. The method is also shown to accurately detect and localise a crack in an aluminium panel and actual impact damage on a carbon fibre reinforced polymer panel.

22 May 2017 in Sensors
Verified
Journal Article
Open access
PDF file
MSMohammad Saleh Salmanpour
Mohammad Saleh Salmanpour
ZZahra Sharif Khodaei
Zahra Sharif Khodaei
M.H. AliabadiM.H. Aliabadi
M.H. Aliabadi
Guided-wave structural health monitoring (SHM) systems with piezoelectric sensors are investigated for localisation of barely visible impact damage in CFRP plates under vibration and different thermal conditions. A single baseline set is used in a delay-and-sum algorithm with temperature correction for damage localisation in a large temperature range. Damage localisation is also demonstrated under transient thermal conditions, with signals recorded while the temperature is rapidly decreased. Damage severity due to successive impact events is studied under constant temperature. Damage is also localised when the plate is subjected to random vibration.

12 December 2016 in Sensors
Verified
Journal Article
Open access
PDF file
MSMohammad Saleh Salmanpour
Mohammad Saleh Salmanpour
ZZahra Sharif Khodaei
Zahra Sharif Khodaei
M.H. AliabadiM.H. Aliabadi
M.H. Aliabadi
This paper investigates the robustness of permanently mounted transducers used in airborne structural health monitoring systems, when exposed to the operational environment. Typical airliners operate in a range of conditions, hence, structural health monitoring (SHM) transducer robustness and integrity must be demonstrated for these environments. A set of extreme temperature, altitude and vibration environment test profiles are developed using the existing Radio Technical Commission for Aeronautics (RTCA)/DO-160 test methods. Commercially available transducers and manufactured versions bonded to carbon fibre reinforced polymer (CFRP) composite materials are tested. It was found that the DuraAct transducer is robust to environmental conditions tested, while the other transducer types degrade under the same conditions.