Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 June 2021 in Journal of Speech, Language, and Hearing Research
Verified
Journal Article
Open access
AKAndreas Kist
Andreas Kist
PGPablo Gómez
Pablo Gómez
DDDenis Dubrovskiy
Denis Dubrovskiy
PSPatrick Schlegel
Patrick Schlegel
MKMelda Kunduk
Melda Kunduk
Michael DöllingerMichael Döllinger
Michael Döllinger
Purpose: High-speed videoendoscopy (HSV) is an emerging, but barely used, endoscopy technique in the clinic to assess and diagnose voice disorders because of the lack of dedicated software to analyze the data. HSV allows to quantify the vocal fold oscillations by segmenting the glottal area. This challenging task has been tackled by various studies; however, the proposed approaches are mostly limited and not suitable for daily clinical routine. Method: We developed a user-friendly software in C# that allows the editing, motion correction, segmentation, and quantitative analysis of HSV data. We further provide pretrained deep neural networks for fully automatic glottis segmentation. Results: We freely provide our software Glottis Analysis Tools (GAT). Using GAT, we provide a general threshold-based region growing platform that enables the user to analyze data from various sources, such as in vivo recordings, ex vivo recordings, and high-speed footage of artificial vocal folds. Additionally, especially for in vivo recordings, we provide three robust neural networks at various speed and quality settings to allow a fully automatic glottis segmentation needed for application by untrained personnel. GAT further evaluates video and audio data in parallel and is able to extract various features from the video data, among others the glottal area waveform, that is, the changing glottal area over time. In total, GAT provides 79 unique quantitative analysis parameters for video- and audio-based signals. Many of these parameters have already been shown to reflect voice disorders, highlighting the clinical importance and usefulness of the GAT software. Conclusion: GAT is a unique tool to process HSV and audio data to determine quantitative, clinically relevant parameters for research, diagnosis, and treatment of laryngeal disorders. Supplemental Material: https://doi.org/10.23641/asha.14575533

21 March 2019 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
PGPablo Gómez
Pablo Gómez
MSMarion Semmler
Marion Semmler
ASAnne Schützenberger
Anne Schützenberger
CBChristopher Bohr
Christopher Bohr
Michael DöllingerMichael Döllinger
Michael Döllinger

21 November 2016 in BioMed Research International
Verified
Journal Article
Open access
PDF file
ASAnne Schützenberger
Anne Schützenberger
MKMelda Kunduk
Melda Kunduk
MDMichael Döllinger
Michael Döllinger
CAChristoph Alexiou
Christoph Alexiou
DDDenis Dubrovskiy
Denis Dubrovskiy
CBChristopher Bohr
Christopher Bohr
The current use of laryngeal high-speed videoendoscopy in clinic settings involves subjective visual assessment of vocal fold vibratory characteristics. However, objective quantification of vocal fold vibrations for evidence-based diagnosis and therapy is desired, and objective parameters assessing laryngeal dynamics have therefore been suggested. This study investigated the sensitivity of the objective parameters and their dependence on recording frame rate. A total of 300 endoscopic high-speed videos with recording frame rates between 1000 and 15 000 fps were analyzed for a vocally healthy female subject during sustained phonation. Twenty parameters, representing laryngeal dynamics, were computed. Four different parameter characteristics were found: parameters showing no change with increasing frame rate; parameters changing up to a certain frame rate, but then remaining constant; parameters remaining constant within a particular range of recording frame rates; and parameters changing with nearly every frame rate. The results suggest that (1) parameter values are influenced by recording frame rates and different parameters have varying sensitivities to recording frame rate; (2) normative values should be determined based on recording frame rates; and (3) the typically used recording frame rate of 4000 fps seems to be too low to distinguish accurately certain characteristics of the human phonation process in detail.

18 December 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PSPatrick Schlegel
Patrick Schlegel
MSMarion Semmler
Marion Semmler
MKMelda Kunduk
Melda Kunduk
Michael DöllingerMichael Döllinger
Michael Döllinger
CBChristopher Bohr
Christopher Bohr
ASAnne Schützenberger
Anne Schützenberger
Laryngeal high-speed videoendoscopy (HSV) allows objective quantification of vocal fold vibratory characteristics. However, it is unknown how the analyzed sequence length affects some of the computed parameters. To examine if varying sequence lengths influence parameter calculation, 20 HSV recordings of healthy females during sustained phonation were investigated. The clinical prevalent Photron Fastcam MC2 camera with a frame rate of 4000 fps and a spatial resolution of 512 × 256 pixels was used to collect HSV data. The glottal area waveform (GAW), describing the increase and decrease of the area between the vocal folds during phonation, was extracted. Based on the GAW, 16 perturbation parameters were computed for sequences of 5, 10, 20, 50 and 100 consecutive cycles. Statistical analysis was performed using SPSS Statistics, version 21. Only three parameters (18.8%) were statistically significantly influenced by changing sequence lengths. Of these parameters, one changed until 10 cycles were reached, one until 20 cycles were reached and one, namely Amplitude Variability Index (AVI), changed between almost all groups of different sequence lengths. Moreover, visually observable, but not statistically significant, changes within parameters were observed. These changes were often most prominent between shorter sequence lengths. Hence, we suggest using a minimum sequence length of at least 20 cycles and discarding the parameter AVI.

9 June 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MSMarion Semmler
Marion Semmler
SKStefan Kniesburges
Stefan Kniesburges
JPJonas Parchent
Jonas Parchent
BJBernhard Jakubaß
Bernhard Jakubaß
MZMaik Zimmermann
Maik Zimmermann
Michael DöllingerMichael Döllinger
Michael Döllinger
Recently, we reported on the in vivo application of a miniaturized measuring device for 3D visualization of the superior vocal fold vibrations from high-speed recordings in combination with a laser projection unit (LPU). As a long-term vision for this proof of principle, we strive to integrate the further developed laserendoscopy as a diagnostic method in daily clinical routine. The new LPU mainly comprises a Nd:YAG laser source (532 nm/CW/2 ω ) and a diffractive optical element (DOE) generating a regular laser grid (31 × 31 laser points) that is projected on the vocal folds. By means of stereo triangulation, the 3D coordinates of the laser points are reconstructed from the endoscopic high-speed footage. The new design of the laserendoscope constitutes a compromise between robust image processing and laser safety regulations. The algorithms for calibration and analysis are now optimized with respect to their overall duration and the number of required interactions, which is objectively assessed using binary classifiers. The sensitivity and specificity of the calibration procedure are increased by 40.1% and 22.3%, which is statistically significant. The overall duration for the laser point detection is reduced by 41.9%. The suggested semi-automatic reconstruction software represents an important stepping-stone towards potential real time processing and a comprehensive, objective diagnostic tool of evidence-based medicine.

3 June 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HSHossein Sadeghi
Hossein Sadeghi
SKStefan Kniesburges
Stefan Kniesburges
SFSebastian Falk
Sebastian Falk
MKManfred Kaltenbacher
Manfred Kaltenbacher
ASAnne Schützenberger
Anne Schützenberger
Michael DöllingerMichael Döllinger
Michael Döllinger
The enormous computational power and time required for simulating the complex phonation process preclude the effective clinical use of computational larynx models. The aim of this study was to evaluate the potential of a numerical larynx model, considering the computational time and resources required. Using Large Eddy Simulations (LES) in a 3D numerical larynx model with prescribed motion of vocal folds, the complicated fluid-structure interaction problem in phonation was reduced to a pure flow simulation with moving boundaries. The simulated laryngeal flow field is in good agreement with the experimental results obtained from authors’ synthetic larynx model. By systematically decreasing the spatial and temporal resolutions of the numerical model and optimizing the computational resources of the simulations, the elapsed simulation time was reduced by 90% to less than 70 h for 10 oscillation cycles of the vocal folds. The proposed computational larynx model with reduced mesh resolution is still able to capture the essential laryngeal flow characteristics and produce results with sufficiently good accuracy in a significant shorter time-to-solution. The reduction in computational time achieved is a promising step towards the clinical application of these computational larynx models in the near future.