Silke Huegl

Ms. Silke Huegl

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 October 2018 in European Archives of Oto-Rhino-Laryngology
Verified
Journal Article
Closed access
PDF file
SHSilke Huegl
Silke Huegl
KRKatharina Rülander
Katharina Rülander
TLThomas Lenarz
Thomas Lenarz
OMOmid Majdani
Omid Majdani
TRThomas S. Rau
Thomas S. Rau

25 February 2017 in European Archives of Oto-Rhino-Laryngology
Verified
Journal Article
Closed access
PDF file
MMMarjan Mirsalehi
Marjan Mirsalehi
TRThomas S. Rau
Thomas S. Rau
LHLenka Harbach
Lenka Harbach
SHSilke Huegl
Silke Huegl
SMSaleh Mohebbi
Saleh Mohebbi
OMOmid Majdani
Omid Majdani

1 October 2019 in Computerized Medical Imaging and Graphics
Verified
Journal Article
Closed access
TRThomas Rau
Thomas Rau
DKDiana Kreul
Diana Kreul
JLJakob Lexow
Jakob Lexow
SHSilke Huegl
Silke Huegl
MZM. Geraldine Zuniga
M. Geraldine Zuniga
OMOmid Majdani
Omid Majdani

17 April 2022 in Biomolecules
Verified
Journal Article
Open access
PDF file
JSJana Schwieger
Jana Schwieger
AFAnna Sophie Frisch
Anna Sophie Frisch
TRThomas Rau
Thomas Rau
TLThomas Lenarz
Thomas Lenarz
SHSilke Huegl
Silke Huegl
Verena ScheperVerena Scheper
Verena Scheper
Cochlear hair cell damage and spiral ganglion neuron (SGN) degeneration are the main causes of sensory neural hearing loss. Cochlear implants (CIs) can replace the function of the hair cells and stimulate the SGNs electrically. The condition of the SGNs and their spatial distance to the CI are key factors for CI-functionality. For a better performance, a high number of neurons and a closer contact to the electrode are intended. Neurotrophic factors are able to enhance SGN survival and neurite outgrowth, and thereby might optimize the electrode-nerve interaction. This would require chronic factor treatment, which is not yet established for the inner ear. Investigations on chronic drug delivery to SGNs could benefit from an appropriate in vitro model. Thus, an inner ear inspired Neurite Outgrowth Chamber (NOC), which allows the incorporation of a mini-osmotic pump for long-term drug delivery, was designed and three-dimensionally printed. The NOC’s function was validated using spiral ganglion explants treated with ciliary neurotrophic factor, neurotrophin-3, or control fluid released via pumps over two weeks. The NOC proved to be suitable for explant cultivation and observation of pump-based drug delivery over the examined period, with neurotrophin-3 significantly increasing neurite outgrowth compared to the other groups.

1 September 2018 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
SHSilke Huegl
Silke Huegl
TBTobias Blum
Tobias Blum
TLThomas Lenarz
Thomas Lenarz
OMOmid Majdani
Omid Majdani
TRThomas S. Rau
Thomas S. Rau
The choice of a cochlear implant electrode carrier for the individual patient is influenced by cochlear size, as this parameter has an impact on the risk of scala dislocations. Therefore, size and morphology should be represented in artificial cochlear models too, since these are generally used for insertion studies evaluating newly developed cochlear implant electrode carriers and insertion techniques, before human temporal bone studies are applied for. Within this study custom-made electrode carrier test samples were inserted into nine artificial cochlear models of different shape. To fabricate them, four human temporal bone samples have been processed by a serial cross-sectioning technique; the other four samples have been scanned with micro computed tomography. The cochlea was segmented on this data using rotating, midmodiolar slice planes, followed by the generation of a three-dimensional digital model, which finally was projected on a plane and 2D models were milled out of PTFE. The ratios of length to width of the cochlear basal turn of our samples were found to be within previously reported range. For comparative reasons a model used in previous studies was included in this study too. The maximal insertion forces per cochlear model followed a normal distribution. The insertion depth at initial insertion force increase is correlated to the length of cochlear basal turn. Using the here presented cochlear models with varying anatomical measures may help to increase the clinical relevance of insertion studies in artificial cochlear models.

1 June 2017 in Mechanism and Machine Theory
Verified
Journal Article
Closed access
LZLena Zentner
Lena Zentner
SGStefan Griebel
Stefan Griebel
CWClemens Wystup
Clemens Wystup
SHSilke Huegl
Silke Huegl
TRThomas Rau
Thomas Rau
OMOmid Majdani
Omid Majdani