Christopher Micallef

Prof. Christopher Micallef

ASME
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2018 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
JSJessica Settino
Jessica Settino
TSTonio Sant
Tonio Sant
CMChristopher Micallef
Christopher Micallef
MFMario Farrugia
Mario Farrugia
CSCyril Spiteri Staines
Cyril Spiteri Staines
Alexander MicallefAlexander Micallef
Alexander Micallef

30 September 2008 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
CMChristopher Micallef
Christopher Micallef
SPStephen Pickering
Stephen Pickering
KSKathy A. Simmons
Kathy A. Simmons
KBKeith J. Bradley
Keith J. Bradley
Computational fluid-dynamics modeling has been used to investigate the cooling of the end region of a two-pole strip-wound totally enclosed fan-cooled induction motor. The modeling is validated by experimental measurements. The changes in airflow and heat transfer that each configuration gives are discussed, and recommendations are made of features that can be used to achieve lower convective thermal resistance in the end region.

1 March 2013 in IET Electric Power Applications
Verified
Journal Article
Open access
PDF file
PCPeter H. Connor
Peter H. Connor
SPStephen Pickering
Stephen Pickering
CGChristopher Gerada
Christopher Gerada
CECarol N. Eastwick
Carol N. Eastwick
CMChristopher Micallef
Christopher Micallef
CTChris Tighe
Chris Tighe
This study is the first in a series dedicated to investigating the airflow and thermal management of electrical machines. Owing to the temperature dependent resistive losses in the machine's windings, any improvement in cooling provides a direct reduction in losses and an increase in efficiency. This study focuses on the airflow which is intrinsically linked to the thermal behaviour of the machine as well as the windage power consumed to drive the air through the machine. A full computational fluid dynamics (CFD) model has been used to analyse the airflow around all major components of the machine. Results have been experimentally validated and investigated. At synchronous speed the experimentally tested mass flow rate and windage torque were under predicted by 4% and 7%, respectively, by the CFD. A break‐down of torque by component shows that the fan consumes approximately 87% of the windage torque.

1 August 2011
Verified
Conference Paper
Closed access
David GeradaDavid Gerada
David Gerada
DBDavid Borg-Bartolo
David Borg-Bartolo
AMAbdeslam Mebarki
Abdeslam Mebarki
CMChristopher Micallef
Christopher Micallef
NBNeil L. Brown
Neil L. Brown
CGChristopher Gerada
Christopher Gerada
This paper discusses the issues associated with the design of high speed machines with a wide constant-power region requirement. Using described multi-physics design environments, which put equal weight on the electromagnetic, thermal and mechanical considerations, the suitability and power density achievable using Induction Machines (IM) and Permanent Magnet Synchronous Machines (PMSM) are compared.

17 November 2016 in Computation
Verified
Journal Article
Open access
PDF file
SOSalem M. Osta-Omar
Salem M. Osta-Omar
CMChristopher Micallef
Christopher Micallef
The objective of this paper is to develop a mathematical model for thermodynamic analysis of an absorption refrigeration system equipped with an adiabatic absorber using a lithium-bromide/water (LiBr/water) pair as the working fluid. The working temperature of the generator, adiabatic absorber, condenser, evaporator, the cooling capacity of the system, and the ratio of the solution mass flow rate at the circulation pump to that at the solution pump are used as input data. The model evaluates the thermodynamic properties of all state points, the heat transfer in each component, the various mass flow rates, and the coefficient of performance (COP) of the cycle. The results are used to investigate the effect of key parameters on the overall performance of the system. For instance, increasing the generator temperatures and decreasing the adiabatic absorber temperatures can increase the COP of the cycle. The results of this mathematical model can be used for designing and sizing new LiBr/water absorption refrigeration systems equipped with an adiabatic absorber or for optimizing existing aforementioned systems.

1 January 2012
Verified
Conference Paper
Closed access
PCP.H. Connor
P.H. Connor
SPStephen Pickering
Stephen Pickering
CGChristopher Gerada
Christopher Gerada
CEC.N. Eastwick
C.N. Eastwick
CMChristopher Micallef
Christopher Micallef