This paper deals with modeling of the doubly-fed induction generator (DFIG) and the corresponding converter for stability studies. To enable efficient computation, a reduced-order DFIG model is developed that restricts the calculation to the fundamental frequency component. However, the model enhancement introduced in this paper allows the consideration of the alternating components of the rotor current as well, which is necessary for triggering the crowbar operation. Suitable models are presented for the rotor and grid side converters as well as the dc-link, taking into account all four possible operating modes. The proposed model for speed and pitch angle control can be used when wind and rotor speed variations are significant. Simulation results are presented for model verification purposes and also for demonstrating the dynamic behavior of a large offshore wind farm connected through a long undersea cable to the high voltage grid.
17 December 2010 in IEEE Transactions on Power Systems
This paper summarizes the work of the Ad Hoc Task Force on Wind Generation Model Validation. The paper describes the concept of model validation, how this applies to wind turbine generation systems, and then gives clear examples of the most recent efforts to achieve model validation for wind turbine power plants. The document ends with a summary of the learning from the work presented and the conclusions which can be derived. Recommendations are made on the path forward for wind turbine generator modeling and model validation, primarily focused on generic models (i.e., standardized and publicly available) for stability analysis in power system studies.
This paper deals with the effectiveness of fault-induced current injection into the system by wind turbines. First, a brief review of the grid code requirement on wind turbines to support voltage profile during fault is reviewed. Based on first principles, analytical expressions quantifying the effectiveness and the limits of the voltage support effort are formulated. This has then been extended to include the limits imposed on output current by the transient stability requirements of the wind park, in which stability constrained current limits through the link wind park - the point of the interconnection and the boundary conditions for stable operation have been derived. Using sample computations, the effect of the violation of this stability limit during fault on the wind park has been analyzed. Finally, a control scheme has been proposed, which on the basis of the voltage dip experienced by the network, reduces the real part of the wind park output current with the objective of enhancing the transient stability margin. Again the effectiveness of the proposed scheme has been demonstrated using sample computations.
This paper provides an overview of the current state of the technology of offshore wind-based power generation and the technological challenges with emphasis on the electrical parts. First, a brief review of the core control functions, their correlation with operational behavior, and the grid-supporting capability of the machine during normal operation as well as during contingency situations are provided. This is followed by the discussion of basic considerations in wind farm collector design, including topology, grounding options, and outlay of the offshore substation. Then, issues related to offshore turbine foundation and typical dimensions of the offshore substation platform are discussed. The platform is designed to accommodate the main and grounding transformers, the switch gear, and other assorted accessories. Next, options for the transmission link from the offshore plant to the grid onshore are reviewed. Finally, a discussion of issues related to grid integration together with currently applicable special grid code requirements concludes the paper.
With the rapid increase of large offshore wind farms in Europe, a new problem associated with the response of wind turbines to temporary overvoltages has arisen. This problem has not been a focus of discussion up to now. The majority of wind turbines use voltage source converters with a DC-link. When the grid voltage exceeds a certain limit the current flow through the line-side converter may reverse, resulting in a rapidly increasing DC voltage. To handle such situations, special countermeasures are required. This paper identifies and outlines the problem and recommends possible measures to ride through the overvoltage safely. Additionally, active voltage control structures to limit the overvoltages are proposed.
22 March 2016 in IEEE Transactions on Energy Conversion
Generic electrical simulation models of wind power generation have been developed as standards, such as the IEC 61400-27-1, to be used by wind industry, system operators, and academia for power system stability studies. In this paper, the IEC type 3 wind turbine model with wind turbine level voltage controller and with wind power plant level power factor controller is validated based on field measurements from a 52-MW wind power plant. In addition to the validation of the IEC type 3 wind turbine and wind power plant controller models, a comparison of the validation approaches, which are the full grid and play-back simulation, is provided together with a survey of the existing validation studies and recommendations for future modeling and validation tasks. The implemented IEC models are tuned to match the measurements accurately and the validated values for the control parameters of the reference wind power plant model are given.