Sumal Nandasena

Dr. Sumal Nandasena

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2010 in BMC Public Health
Verified
Journal Article
Open access
PDF file
SNSumal Nandasena
Sumal Nandasena
AWAnanda Rajitha Wickremasinghe
Ananda Rajitha Wickremasinghe
NSNalini Sathiakumar
Nalini Sathiakumar
Air pollution is increasingly documented as a threat to public health in most developing countries. Evaluation of current air quality levels, regulatory standards and scientific literature on outdoor and indoor air pollution, and health effects are important to identify the burden, develop and implement interventions and to fill knowledge gaps in Sri Lanka.

1 January 2013 in World Journal of Clinical Pediatrics
Verified
Journal Article
Open access
SNSumal Nandasena
Sumal Nandasena
AWAnanda Rajitha Wickremasinghe
Ananda Rajitha Wickremasinghe
NSNalini Sathiakumar
Nalini Sathiakumar
Indoor air pollution (IAP) is a key contributor to the global burden of disease mainly in developing countries. The use of solid fuel for cooking and heating is the main source of IAP in developing countries, accounting for an estimated 3.5 million deaths and 4.5% of Disability-Adjusted Life Years in 2010. Other sources of IAP include indoor smoking, infiltration of pollutants from outdoor sources and substances emitted from an array of human utilities and biological materials. Children are among the most vulnerable groups for adverse effects of IAP. The respiratory system is a primary target of air pollutants resulting in a wide range of acute and chronic effects. The spectrum of respiratory adverse effects ranges from mild subclinical changes and mild symptoms to life threatening conditions and even death. However, IAP is a modifiable risk factor having potential mitigating interventions. Possible interventions range from simple behavior change to structural changes and from shifting of unclean cooking fuel to clean cooking fuel. Shifting from use of solid fuel to clean fuel invariably reduces household air pollution in developing countries, but such a change is challenging. This review aims to summarize the available information on IAP exposure during childhood and its effects on respiratory health in developing countries. It specifically discusses the common sources of IAP, susceptibility of children to air pollution, mechanisms of action, common respiratory conditions, preventive and mitigating strategies.

2 September 2019 in BMC Pediatrics
Verified
Journal Article
Open access
PDF file
NRNayomi Ranathunga
Nayomi Ranathunga
PPPriyantha Perera
Priyantha Perera
SNSumal Nandasena
Sumal Nandasena
NSNalini Sathiakumar
Nalini Sathiakumar
AKAnuradhani Kasturiratne
Anuradhani Kasturiratne
AWAnanda Rajitha Wickremasinghe
Ananda Rajitha Wickremasinghe
Household air pollution from combustion of solid fuels for cooking and space heating is one of the most important risk factors of the global burden of disease. This study was aimed to determine the association between household air pollution due to combustion of biomass fuel in Sri Lankan households and self-reported respiratory symptoms in children under 5 years. A prospective study was conducted in the Ragama Medical Officer of Health area in Sri Lanka. Children under 5 years were followed up for 12 months. Data on respiratory symptoms were extracted from a symptom diary. Socioeconomic data and the main fuel type used for cooking were recorded. Air quality measurements were taken during the preparation of the lunch meal over a 2-h period in a subsample of households. Two hundred and sixty two children were followed up. The incidence of infection induced asthma (RR = 1.77, 95%CI;1.098–2.949) was significantly higher among children resident in households using biomass fuel and kerosene (considered as the high exposure group) as compared to children resident in households using Liquefied Petroleum Gas (LPG) or electricity for cooking (considered as the low exposure group), after adjusting for confounders. Maternal education was significantly associated with the incidence of infection induced asthma after controlling for other factors including exposure status. The incidence of asthma among male children was significantly higher than in female children (RR = 1.17; 95% CI 1.01–1.37). Having an industry causing air pollution near the home and cooking inside the living area were significant risk factors of rhinitis (RR = 1.39 and 2.67, respectively) while spending less time on cooking was a protective factor (RR = 0.81). Houses which used biomass fuel had significantly higher concentrations of carbon monoxide (CO) (mean 2.77 ppm vs 1.44 ppm) and particulate matter2.5 (PM2.5) (mean 1.09 mg/m3 vs 0.30 mg/m3) as compared to houses using LPG or electricity for cooking. The CO and PM2.5 concentrations were significantly higher in households using biomass fuel for cooking. There was a 1.6 times higher risk of infection induced asthma (IIA) among children of the high exposure group as compared to children of the low exposure group, after controlling for other factors. Maternal education was significantly associated with the incidence of IIA after controlling for exposure status and other variables.

1 September 2006 in Transactions of the Royal Society of Tropical Medicine and Hygiene
Verified
Journal Article
Closed access
APA. Pathmeswaran
A. Pathmeswaran
AKA. Kasturiratne
A. Kasturiratne
MFM. Fonseka
M. Fonseka
SNSumal Nandasena
Sumal Nandasena
DLD.G. Lalloo
D.G. Lalloo
HSH.J. de Silva
H.J. de Silva
The outcome of snakebite is related to the biting species but it is often difficult to identify the biting snake, particularly in community settings. We have developed a clinical scoring system suitable for use in epidemiological surveys, with the main aim of identifying the presumed biting species in those with systemic envenoming who require treatment. The score took into account ten features relating to bites of the five medically important snakes in Sri Lanka, and an algorithm was developed applying different weightings for each feature for different species. A systematically developed artificial data set was used to fine tune the score and to develop criteria for definitive identification. The score was prospectively validated using 134 species-confirmed snakebites. It correctly differentiated the bites caused by the three snakes that commonly cause major clinical problems (Russell's viper (RV), kraits and cobra) from other snakes (hump-nosed viper (HNV) and saw-scaled viper (SSV)) with 80% sensitivity and 100% specificity. For individual species, sensitivity and specificity were, respectively: cobra 76%, 99%; kraits 85%, 99%; and RV 70%, 99%. As anticipated, the score was insensitive in the identification of bites due to HNV and SSV.

1 September 2010 in International Journal of Hygiene and Environmental Health
Verified
Journal Article
Closed access
JLJiyeon Lee
Jiyeon Lee
SLSoogil Lim
Soogil Lim
KLKiyoung Lee
Kiyoung Lee
XGXinbiao Guo
Xinbiao Guo
RKRamachandra Kamath
Ramachandra Kamath
NSNalini Sathiakumar
Nalini Sathiakumar

MPMichael Phillips
Michael Phillips
ESEmily A. Smith
Emily A. Smith
PMPaul L. Mosquin
Paul L. Mosquin
RCRyan Chartier
Ryan Chartier
SNSumal Nandasena
Sumal Nandasena
LBLinda Morris Brown
Linda Morris Brown
A pilot study of indoor air pollution produced by biomass cookstoves was conducted in 53 homes in Sri Lanka to assess respiratory conditions associated with stove type (“Anagi” or “Traditional”), kitchen characteristics (e.g., presence of a chimney in the home, indoor cooking area), and concentrations of personal and indoor particulate matter less than 2.5 micrometers in diameter (PM2.5). Each primary cook reported respiratory conditions for herself (cough, phlegm, wheeze, or asthma) and for children (wheeze or asthma) living in her household. For cooks, the presence of at least one respiratory condition was significantly associated with 48-h log-transformed mean personal PM2.5 concentration (PR = 1.35; p < 0.001). The prevalence ratio (PR) was significantly elevated for cooks with one or more respiratory conditions if they cooked without a chimney (PR = 1.51, p = 0.025) and non-significantly elevated if they cooked in a separate but poorly ventilated building (PR = 1.51, p = 0.093). The PRs were significantly elevated for children with wheeze or asthma if a traditional stove was used (PR = 2.08, p = 0.014) or if the cooking area was not partitioned from the rest of the home (PR = 2.46, p = 0.012). For the 13 children for whom the cooking area was not partitioned from the rest of the home, having a respiratory condition was significantly associated with log-transformed indoor PM2.5 concentration (PR = 1.51; p = 0.014).