Matthias Hey

Dr. Matthias Hey


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 July 2014 in International Journal of Audiology
Verified
Journal Article
Closed access
PDF file
MHMatthias Hey
Matthias Hey
THThomas Hocke
Thomas Hocke
JHJürgen Hedderich
Jürgen Hedderich
JMJoachim Müller-Deile
Joachim Müller-Deile
Objective: The aim of this study was to describe common properties (reproducibility, discrimination function, and its steepness) of matrix tests used for cochlear implant (CI) users and to obtain data for the German-language version matrix test, the Oldenburg sentence test (OLSA), presented in noise. Design: The speech reception thresholds (SRT) in noise were measured by means of an adaptive test procedure, and by measurement at various signal-to-noise ratios to determine the course of the entire discrimination function per subject. Study sample: The measurements were performed on 38 CI users fitted with a Cochlear™ Freedom® or a Cochlear™ Nucleus® 5 CI system. Results: The test–retest reproducibility showed a significant dependence on the SRT in noise. For the better performers, the test-retest difference was found to be smaller, while for the poorer performers the difference increased. For the better performers, the slope of the discrimination function at SRT (s50) was comparable to that for individuals with normal hearing, while for the poorer performers the s50 tended to be significantly reduced. Conclusions: As the CI users differed significantly in their SRT and their s50, a unified discrimination function for CI users must not be used. Further tailoring of the procedure may be required, especially for poorer CI performers.

29 August 2019 in International Journal of Audiology
Verified
Journal Article
Open access
MHMatthias Hey
Matthias Hey
THThomas Hocke
Thomas Hocke
BBBritta Böhnke
Britta Böhnke
SMStefan J. Mauger
Stefan J. Mauger
Objective: To clinically evaluate ForwardFocus in noise with experienced Nucleus® cochlear implant (CI) recipients. Design: Listening performance with ForwardFocus was compared against the best in class directional microphone program (BEAM®). Speech comprehension was tested with the Oldenburg sentence test with competing signals (stationary, three, six and 18-talker babble) in both co-located and spatially-separated listening environments. Additionally, normal hearing participants were tested monaurally in the same listening environments as a reference and to promote cross-study comparisons between CI clinical study outcomes. Study sample: Post-lingually deaf adult CI recipients (n = 20) who were experienced users of the Nucleus sound processor (Cochlear Limited). Results: Improved speech comprehension was found with the ForwardFocus program compared to the BEAM program in a co-located frontal listening environment for both stationary and fluctuating competing signals. In spatially-separated environments ForwardFocus provided significant speech reception threshold (SRT) improvements of 5.8 dB for three-talker competing signals, respectively. Conclusions: ForwardFocus was shown to significantly improve speech comprehension in a wide range of listening environments. This technology is likely to provide significant improvements in real-world listening for CI recipients, given the clinically relevant performance outcomes in challenging dynamic noise environments, bringing their performance closer to their normal hearing peers.

8 June 2016 in European Archives of Oto-Rhino-Laryngology
Verified
Journal Article
Open access
PDF file
MHMatthias Hey
Matthias Hey
THThomas Hocke
Thomas Hocke
SMStefan Mauger
Stefan Mauger
JMJoachim Müller-Deile
Joachim Müller-Deile
Individual speech intelligibility was measured in quiet and noise for cochlear Implant recipients upgrading from the Freedom to the CP900 series sound processor. The postlingually deafened participants (n = 23) used either Nucleus CI24RE or CI512 cochlear implant, and currently wore a Freedom sound processor. A significant group mean improvement in speech intelligibility was found in quiet (Freiburg monosyllabic words at 50 dBSPL) and in noise (adaptive Oldenburger sentences in noise) for the two CP900 series SmartSound programs compared to the Freedom program. Further analysis was carried out on individual’s speech intelligibility outcomes in quiet and in noise. Results showed a significant improvement or decrement for some recipients when upgrading to the new programs. To further increase speech intelligibility outcomes when upgrading, an enhanced upgrade procedure is proposed that includes additional testing with different signal-processing schemes. Implications of this research are that future automated scene analysis and switching technologies could provide additional performance improvements by introducing individualized scene-dependent settings.

1 January 2015 in Journal of Neuroscience Methods
Verified
Journal Article
Closed access
MHMatthias Hey
Matthias Hey
JMJoachim Müller-Deile
Joachim Müller-Deile

1 November 2017 in Hearing Research
Verified
Journal Article
Open access
MHMatthias Hey
Matthias Hey
JMJoachim Müller-Deile
Joachim Müller-Deile
HHHorst Hessel
Horst Hessel
MKMatthijs Killian
Matthijs Killian
In this study we aim to resolve the contributions of facilitation and refractoriness at very short pulse intervals. Measurements of the refractory properties of the electrically evoked compound action potential (ECAP) of the auditory nerve in cochlear implant (CI) users at inter pulse intervals below 300 μs are influenced by facilitation and recovery effects. ECAPs were recorded using masker pulses with a wide range of current levels relative to the probe pulse levels, for three suprathreshold probe levels and pulse intervals from 13 to 200 μs. Evoked potentials were measured for 21 CI patients by using the masked response extraction artifact cancellation procedure. During analysis of the measurements the stimulation current was not used as absolute value, but in relation to the patient's individual ECAP threshold. This enabled a more general approach to describe facilitation as a probe level independent effect. Maximum facilitation was found for all tested inter pulse intervals at masker levels near patient's individual ECAP threshold, independent from probe level. For short inter pulse intervals an increased N1P1 amplitude was measured for subthreshold masker levels down to 120 CL below patient's individual ECAP threshold in contrast to the recreated state. ECAPs recorded with inter pulse intervals up to 200 μs are influenced by facilitation and recovery. Facilitation effects are most pronounced for masker levels at or below ECAP threshold, while recovery effects increase with higher masker levels above ECAP threshold. The local maximum of the ECAP amplitude for masker levels around ECAP threshold can be explained by the mutual influence of maximum facilitation and minimal refractoriness.

8 July 2016 in HNO
Verified
Journal Article
Closed access
PDF file
MHMatthias Hey
Matthias Hey
GBG. Brademann
G. Brademann
PAP. Ambrosch
P. Ambrosch