Saleh Naser Almohammed

Prof. Dr. Saleh Naser Almohammed

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 October 2021 in Heliyon
Verified
Journal Article
Open access
TZTareq A. Ziyad
Tareq A. Ziyad
LALayla Abu-naba'a
Layla Abu-naba'a
SASaleh Naser Almohammed
Saleh Naser Almohammed
This in vitro investigation aims to evaluate and compare optical properties of three types of esthetic CAD-CAM monolithic multi-layered zirconia materials with a control (conventional lithium disilicate, IPS e. max CAD). Four monolithic CAD-CAM ceramic materials were investigated: Ceramill Zolid® FX Multilayer (ZF), IPS e. max® ZirCAD MT Multi (ZM), Katana® STML (KS) and one lithium disilicate glass-ceramics as a control (IPS e. max® CAD LT; LC). A total of 72 (15 × 15 × 1 mm) samples were CAD CAM fabricated and sintered based on sample-size power calculations, and each material comprised 18 samples. The translucency and opalescence parameters with the contrast ratio were evaluated with a dental spectrophotometer over the backgrounds of black and white. The data were analyzed by ANOVA, then Bonferroni post hoc comparison test was made between groups. The statistical significance was set at p < 0.05. Zirconia materials revealed lower optical properties than the lithium disilicate control LC (P < 0.05). TP values ranged from 14.174 to 20.439. No differences were detected between the zirconia products in terms of TP and CR (P = 1.000). OP values ranged from 5.068 to 10.097. The lowest OP values were found statistically significant for ZF followed by KS and ZM (P = 1.000). LC had the highest TP and OP values, as well as the lowest CR (p < 0.05). The optical properties of monolithic zirconia systems tested here are still lower than those of lithium disilicate glass-ceramics. The only difference observed between the monolithic CAD CAM zirconia materials, was for the low opalescence parameter for the ZF. Multi-layered monolithic zirconia systems have better esthetics by shade layers resembling natural tooth color gradients. CAD-CAM technology allowed for in-office milling and shaping of restorations using these systems. This study reports on their optical properties affecting human vision/perception of natural tooth shade to conclude about their use in the esthetic zones.

24 April 2023 in Ceramics
Verified
Journal Article
Open access
PDF file
SASaleh Naser Almohammed
Saleh Naser Almohammed
BABelal Alshorman
Belal Alshorman
LALayla Abu-naba'a
Layla Abu-naba'a
Monolithic zirconia and hybrid ceramic restorations have been widely used in the last decade for both anterior and posterior dental restorations. However, their use lacks sufficient scientific evidence in most cases, as the expeditious manufacturing of these versatile ceramic materials exceeds the limits of in vitro and/or in vivo validation. This study aimed to evaluate and compare the mechanical properties (flexural strength, fracture toughness, Vickers hardness, and brittleness index) of three CAD-CAM monolithic multilayer zirconia ceramics (GNX—Ceramill Zolid® Gen-X, ZCP—IPS e.max® ZirCAD, and UPC—Upcera® Esthetic Explore Prime) and one CAD-CAM monolithic multilayer polymer-infiltrated hybrid ceramic (ENM—Vita® Enamic) with a CAD-CAM monolithic lithium disilicate ceramic as a control (EMX —IPS e.max® CAD). A total of 160 discs (GNX = 32, ZCP = 32, UPC = 32, ENM = 32, and EMX = 32) were cut, polished, and fully sintered (except for the ENM). Half of the samples for each group were subjected to hydrothermal aging. Descriptive analysis and ANOVA tests were used to compare the groups. The zirconia groups showed significantly higher mechanical properties than the EMX group for both the non-aged and aged samples (p < 0.05). The ENM group showed the lowest brittleness index, while EMX showed the highest. The mechanical properties of monolithic multilayer zirconia ceramics were generally better than those of monolithic multilayer polymer-infiltrated hybrid ceramic and lithium disilicate ceramic. All groups showed, to some extent, a change in their mechanical properties after aging, with the ENM being the most affected.

10 November 2022 in Ceramics
Verified
Journal Article
Open access
PDF file
SASaleh Naser Almohammed
Saleh Naser Almohammed
BABelal Alshorman
Belal Alshorman
LALayla Abu-naba'a
Layla Abu-naba'a
Zirconia has generated tremendous interest in the esthetic materials used for dental restorations. However, using conventional zirconia has some limitations especially in highly esthetically demanding situations, as it lacks the translucency that other ceramic materials possess. This study aimed to evaluate and compare the optical properties (shade, translucency, and opalescence) of three CAD-CAM monolithic multilayer zirconia ceramics (GNX; Ceramill Zolid® Gen-X, ZCP; IPS e.max® ZirCAD, and UPC; Upcera® Esthetic Explore Prime) and one CAD-CAM monolithic multilayer polymer-infiltrated hybrid ceramic (ENM; Vita® Enamic) with a CAD-CAM monolithic lithium disilicate ceramic as control (EMX; IPS e.max® CAD). 200 discs (GNX = 40, ZCP = 40, UPC = 40, ENM = 40, and EMX = 40) were cut, polished, and fully crystallized. Half of the samples for each group were subjected to hydrothermal aging. Descriptive analysis and ANOVA tests were used to compare the groups. Zirconia GNX, ZCP, and UPC groups showed significantly lower optical properties than ENM and EMX groups for both the non-aged and aged samples (p < 0.05). UPC and ENM groups showed a significant decrease in translucency and opalescence after aging (p < 0.05). The optical properties of monolithic multilayer zirconia ceramics were lower than monolithic multilayer polymer-infiltrated hybrid ceramic and lithium disilicate ceramic. Polymer-infiltrated hybrid ceramic was significantly affected by aging.

18 November 2021 in Journal of Esthetic and Restorative Dentistry
Verified
Journal Article
Closed access
PDF file
KHKhaled Q. Al Hamad
Khaled Q. Al Hamad
SASaleh Naser Almohammed
Saleh Naser Almohammed
NBNadim Z Baba
Nadim Z Baba

16 September 2022 in Case Reports in Dentistry
Verified
Journal Article
Open access
SASaleh Naser Almohammed
Saleh Naser Almohammed
RAReem S. Abdel-Hafez
Reem S. Abdel-Hafez
DADuaa D. Ailabouni
Duaa D. Ailabouni
Immediate replacement of teeth designated for extraction is an appealing treatment rationale for both the patient and the operator. However, it has been associated with a greater risk of facial recession and compromised soft‐tissue esthetics. Partial extraction therapy (PET) or synonymously socket shield technique (SST) or root membrane technique (RMT) has been proposed to conserve the facial alveolar contour and soft‐tissue esthetics. In this article, a special case is described where a root membrane was used to prevent the modeling of the facial aspect of the extraction socket. Partial extraction was performed allowing the socket with the facial root membrane in situ to partially heal for 8 weeks before implant placement. Successful integration and restoration were achieved with very minimal hard‐ and soft‐tissue changes, accentuating satisfactory esthetic results as dictated by objective esthetic assessment. PET with early implant placement may be considered a viable treatment option for selected cases.

10 November 2025 in Ceramics
Verified
Journal Article
Open access
PDF file
LALayla Abu-naba'a
Layla Abu-naba'a
SASaleh Naser Almohammed
Saleh Naser Almohammed
TZTareq Abdulazeez Ziyad
Tareq Abdulazeez Ziyad
Transparent CAD/CAM monolithic ceramics are increasingly used in dentistry due to their combination of high strength, esthetics, and durability, achieved through high yttria content and multilayered systems. This study evaluates the mechanical behavior of four widely used CAD/CAM ceramics, correlating their performance with microstructural characteristics. Bar-shaped specimens (n = 10 per material, for each test) of ZOLID® FX ML (ZF), IPS E.MAX® CAD (MC), E.MAX® ZIRCAD (ZM), and KAT-ANA® STML (KS) (all A2 shade) were prepared and sintered according to manufacturers’ protocols. Flexural strength and elastic modulus were measured using three-point bending, and Vickers hardness was determined separately. Statistical normality was confirmed with the Kolmogorov–Smirnov test. Flexural strength ranged from 252.8 ± 39.8 MPa (MC) to 547.6 ± 125.7 MPa (ZM), elastic modulus from 65.8 ± 6.5 GPa (MC) to 94.1 ± 5.8 GPa (KS), and hardness from 4.2 ± 0.2 GPa (MC) to 9.6 ± 0.6 GPa (ZF). High-elastic-modulus materials (KS, ZM) can better resist deformation under occlusal loads, improving long-term stability of posterior crowns, bridges, and implant-supported restorations. High hardness (ZF) provides superior wear resistance and preserves occlusal anatomy over time, making it suitable for thin-shell restorations and high-stress functional surfaces. Materials with lower modulus and hardness (MC) are more suitable for intra-coronal restorations or thin veneers where stress shielding and material compliance are advantageous. These findings support material selection based on mechanical demands, and further clinical studies are needed to confirm long-term performance.