Mehmet Kanoglu

Prof. Mehmet Kanoglu


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 June 2002 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
MKMehmet Kanoglu
Mehmet Kanoglu
This paper provides an exergy analysis of the multistage cascade refrigeration cycle used for natural gas liquefaction. The equations of exergy destruction and exergetic efficiency for the main cycle components such as evaporators, condensers, compressors, and expansion valves are developed. The relations for the total exergy destruction in the cycle and the cycle exergetic efficiency are obtained. Also, an expression for the minimum work requirement for the liquefaction of natural gas is developed. It is shown that the minimum work depends only on the properties of the incoming and outgoing natural gas, and it increases with decreasing liquefaction temperature. The minimum work for a typical natural gas inlet and exit state is determined to be 456.8 kJ kg−1 of liquefied natural gas (LNG), which corresponds to a coefficient of performance (COP) of 1.8. Using a typical actual work input value; the exergetic efficiency of the multistage cascade refrigeration cycle is determined to be 38.5% indicating a great potential for improvements. Copyright © 2002 John Wiley & Sons, Ltd.

1 October 2015 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
CYCEYHUN YILMAZ
CEYHUN YILMAZ
MKMehmet Kanoglu
Mehmet Kanoglu
AAAysegul Abusoglu
Aysegul Abusoglu

1 January 2019 in Geothermics
Verified
Journal Article
Closed access
TCTugberk Hakan Cetin
Tugberk Hakan Cetin
MKMehmet Kanoglu
Mehmet Kanoglu
NYNeslihan Yanikomer
Neslihan Yanikomer

1 September 2015 in Geothermics
Verified
Journal Article
Closed access
CYCEYHUN YILMAZ
CEYHUN YILMAZ
MKMehmet Kanoglu
Mehmet Kanoglu
AAAysegul Abusoglu
Aysegul Abusoglu


10 September 2025 in Entropy
Verified
Journal Article
Open access
PDF file
YCYunus Cengel
Yunus Cengel
MKMehmet Kanoglu
Mehmet Kanoglu
Exergy efficiency is viewed as the degree of approaching reversible operation, with a value of 100 percent for a reversible process characterized by zero entropy generation or equivalently zero exergy destruction since Xdestroyed = T0Sgen. As such, exergy efficiency becomes a measure of thermodynamic perfection. There are different conceptual definitions of exergy efficiency, the most common ones being (1) the ratio of exergy output to exergy input ηex = Xoutput/Xinput = 1 − (Xdestroyed + Xloss)/Xinput, (2) the ratio of the product exergy to fuel exergy ηex = Xproduct/Xfuel = 1 − (Xdestroyed + Xloss)/Xfuel, and (3) the ratio of exergy recovered to exergy expended ηex = Xrecovered/Xexpended = 1 − Xdestroyed/Xexpended. Most exergy efficiency definitions are formulated with steady-flow systems in mind, and they are generally applied to systems in steady operation such as power plants and refrigeration systems whose exergy content remains constant. If these definitions are to be used for closed and unsteady-flow systems, the terms need to be interpreted broadly to account for the exergy change of the systems as exergy input or output, as appropriate. In this paper, general exergy efficiency relations are developed for closed and unsteady-flow systems and their use is demonstrated with applications. Also, the practicality of the use of the term exergy loss Xloss is questioned, and limitations on the definition ηex = Wact,out/Wrev,out are discussed.