Application of the air‐puff swept source OCT (SS‐OCT) instrument to determine the influence of viscoelasticity on the relation between overall the air‐puff force and corneal apex displacement of porcine corneas ex vivo is demonstrated. Simultaneous recording of time‐evolution of the tissue displacement and air pulse stimulus allows obtaining valuable information related in part to the mechanical properties of the cornea. A novel approach based on quantitative analysis of the corneal hysteresis of OCT data is presented. The corneal response to the air pulse is assessed for different well‐controlled IOP levels and for the progression of cross‐linking induced stiffness of the cornea. Micrometer resolution, fast acquisition and non‐contact character of the air‐puff SS‐OCT measurements have potential to improve the in vivo assessment of mechanical properties of the human corneas.
Introduction and Hypothesis. Some papers have shown that bone mineral density (BMD) may not be accurate in predicting fracture risk. Recently microarchitecture parameters have been reported to give information on bone characteristics. The aim of this study was to find out if the values of volume, fractal dimension, and bone mineral density are correlated with bone strength.Methods. Forty-two human bone samples harvested during total hip replacement surgery were cut to cylindrical samples. The geometrical mesh of layers of bone mass obtained from microCT investigation and the volumes of each layer and fractal dimension were calculated. The finite element method was applied to calculate the compression forceFcausing% strain.Results. There were stronger correlations for microarchitecture parameters with strength than those for bone mineral density. The values of determination coefficientR2for mean volume and force were 0.88 and 0.90 for mean fractal dimension and force, while for BMD and force the value was 0.53. The samples with bigger mean bone volume of layers and bigger mean fractal dimension of layers (more complex structure) presented higher strength.Conclusion. The volumetric and fractal dimension parameters better describe bone structure and strength than BMD.
1 November 2011 in Journal of the Mechanical Behavior of Biomedical Materials
The research method proposed in the paper assumes multi-level loads of trabecular bone, which are similar to the real ones and demonstrate a step-wise amplitude increase. Throughout the study, such loadings were applied to bone structures sampled from 61 donors. The samples were obtained after hip arthroplasty from the neck fragment of femur heads. All the samples were scanned with a desktop microtomographer. The fatigue damage of the sample structures throughout the experiments was seen in changes in the form of the hysteresis loop recorded in the stress-strain system. The dissipation energy, which is calculated based on the hysteresis loop, is present in the fatigue life function. A three-stage sample fatigue damage pattern was demonstrated. The sum of the dissipation energies was calculated for all the hysteresis loops, and thus we obtain the accumulated dissipation energy, which is referred to as the total fatigue life for all the samples. The calculation results were determined to have an exponential-like curve and reported a high value of the coefficient of determinacy. The accumulated dissipation energy is also related to the value of the compressive stress levels applied. Referring the calculated results of the accumulated energy to the structure index BV/TV, we identified the existence of a strong relationship between the quantities.
This study proposes to design a road support structure subjected to high-strain-rate loading occurring during vehicle collisions. The strain-rate affects both the hardening process and the material failure process. For modeling the strain-rate influence on material, various mathematical material models are used including the Johnoson-Cook model. The main goal of the study is to presenta method for determining the parameters for the Johnson-Cook damage model, a hybrid method which requires Charpy impact tests on a standard specimen with an annular notch and a series of calculations using finite element method simulating the test. The advantages of the presented method compared to existing methods are the high availability of the equipment, simple and quick processing of results and significantly lower costs.
Trabecular bone cores were collected from the femoral head at the time of surgery (hip arthroplasty). Investigated were 42 specimens, from patients with osteoporosis and coxarthrosis. The cores were scanned used computer microtomography (microCT) system at an isotropic spatial resolution of 36 microns. Image stacks were converted to finite element models via a bone voxel-to-element algorithm. The apparent modulus was calculated based on the assumptions that for the elastic properties, MPa and. The compressive deformation as calculated by finite elements (FE) analysis was 0.8%. The models were coarsened to effectively change the resolution or voxel size (from 72 microns to 288 microns or from 72 microns to 1080 microns). The aim of our study is to determine how an increase in the distance between scans changes the elastic properties as calculated by FE models. We tried to find a border value voxel size at which the module values were possible to calculate. As the voxel size increased, the mean voxel volume increased and the FEA-derived apparent modulus decreased. The slope of voxel size versus modulus relationship correlated with several architectural indices of trabecular bone.