Alonso Alonso Alonso

Prof. Dr. Alonso Alonso Alonso

orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 1999 in IEEE Engineering in Medicine and Biology Magazine
Verified
Journal Article
Closed access
Roberto HorneroRoberto Hornero
Roberto Hornero
PEP. Espino
P. Espino
AAAlonso Alonso Alonso
Alonso Alonso Alonso
MLM. Lopez
M. Lopez
We analyze the EEG background activities of five epileptic patients and compare them with the EEGs of five control subjects by means of methods from nonlinear dynamical system theory. We divided the EEG time-series data into frames to select those that fulfilled the stationarity condition, which is necessary in order to apply our methods. Then, we reconstructed the chaotic dynamic attractors expressed in the phase space and calculated their correlation dimensions, which are a measure of the complexity. Furthermore, we recorded an EEG during a petit mal epileptic seizure, whose attractor is a 3-D plot and the correlation dimension will also be presented.

7 December 2010 in Sensors
Verified
Journal Article
Open access
PDF file
RRRamón De La Rosa
Ramón De La Rosa
AAAlonso Alonso Alonso
Alonso Alonso Alonso
ACAlbano Carrera
Albano Carrera
Ramón J. Durán BarrosoRamón J. Durán Barroso
Ramón J. Durán Barroso
PFPatricia Fernández
Patricia Fernández
This paper presents the UVa-NTS (University of Valladolid Neuromuscular Training System), a multifunction and portable Neuromuscular Training System. The UVa-NTS is designed to analyze the voluntary control of severe neuromotor handicapped patients, their interactive response, and their adaptation to neuromuscular interface systems, such as neural prostheses or domotic applications. Thus, it is an excellent tool to evaluate the residual muscle capabilities in the handicapped. The UVa-NTS is composed of a custom signal conditioning front-end and a computer. The front-end electronics is described thoroughly as well as the overall features of the custom software implementation. The software system is composed of a set of graphical training tools and a processing core. The UVa-NTS works with two classes of neuromuscular signals: the classic myoelectric signals (MES) and, as a novelty, the myomechanic signals (MMS). In order to evaluate the performance of the processing core, a complete analysis has been done to classify its efficiency and to check that it fulfils with the real-time constraints. Tests were performed both with healthy and selected impaired subjects. The adaptation was achieved rapidly, applying a predefined protocol for the UVa-NTS set of training tools. Fine voluntary control was demonstrated to be reached with the myoelectric signals. And the UVa-NTS demonstrated to provide a satisfactory voluntary control when applying the myomechanic signals.

1 January 1999 in IEEE Engineering in Medicine and Biology Magazine
Verified
Journal Article
Open access
Roberto HorneroRoberto Hornero
Roberto Hornero
AAAlonso Alonso Alonso
Alonso Alonso Alonso
NJN. Jimeno
N. Jimeno
AJA. Jimeno
A. Jimeno
MLM. Lopez
M. Lopez

1 August 2008
Verified
Conference Paper
Closed access
RRRamón De La Rosa
Ramón De La Rosa
AAAlonso Alonso Alonso
Alonso Alonso Alonso
SRS. de la Rosa
S. de la Rosa
Daniel AbasoloDaniel Abasolo
Daniel Abasolo
This paper presents the game Myo-Pong, a simple graphical table-tennis game included in the portable UVa Neuromuscular Training System (UVa-NTS). Myo-Pong demonstrates the capabilities of the UVa-NTS as a myoelectric real-time system for training and for playing by means of myoelectric control.

24 March 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ACAlbano Carrera
Albano Carrera
AAAlonso Alonso Alonso
Alonso Alonso Alonso
RRRamón De La Rosa
Ramón De La Rosa
EAEvaristo J. Abril
Evaristo J. Abril
This paper presents a glove designed to assess the viability of communication between a deaf-blind user and his/her interlocutor through a vibrotactile device. This glove is part of the TactileCom system, where communication is bidirectional through a wireless link, so no contact is required between the interlocutors. Responsiveness is higher than with letter by letter wording. The learning of a small set of concepts is simpler and the amount learned can be increased at the user’s convenience. The number of stimulated fingers, the keying frequencies and finger response were studied. Message identification rate was 97% for deaf-blind individuals and 81% for control subjects. Identification by single-finger stimulation was better than by multiple-finger stimulation. The interface proved suitable for communication with deaf-blind individuals and can also be used in other conditions, such as multilingual or noisy environments.

19 August 2014 in Radiation Protection Dosimetry
Verified
Journal Article
Open access
PDF file
Javier PrietoJavier Prieto
Javier Prieto
AAAlonso Alonso Alonso
Alonso Alonso Alonso
RRRamón De La Rosa
Ramón De La Rosa
ACAlbano Carrera
Albano Carrera
Misinterpretation of uncertainty in the measurement of the electromagnetic field (EMF) strength may lead to an underestimation of exposure risk or an overestimation of required measurements. The Guide to the Expression of Uncertainty in Measurement (GUM) has internationally been adopted as a de facto standard for uncertainty assessment. However, analyses under such an approach commonly assume unrealistic static models or neglect relevant prior information, resulting in non-robust uncertainties. This study proposes a principled and systematic framework for uncertainty analysis that fuses information from current measurements and prior knowledge. Such a framework dynamically adapts to data by exploiting a likelihood function based on kernel mixtures and incorporates flexible choices of prior information by applying importance sampling. The validity of the proposed techniques is assessed from measurements performed with a broadband radiation meter and an isotropic field probe. The developed framework significantly outperforms GUM approach, achieving a reduction of 28 % in measurement uncertainty.