Fengge Wang

Dr. Fengge Wang


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
JSJunyu Shen
Junyu Shen
YXYanyan Xu
Yanyan Xu
ZXZhengwen Xiao
Zhengwen Xiao
YLYuebo Liu
Yuebo Liu
HLHonghui Liu
Honghui Liu
BZBaijun Zhang
Baijun Zhang
Optrodes, which are single shaft neural probes integrated with microelectrodes and optical light sources, offer a remarkable opportunity to simultaneously record and modulate neural activities using light within an animal’s brain; however, a common problem with optrodes is that stimulation artifacts can be observed in the neural recordings of microelectrodes when the light source on the optrode is activated. These stimulation artifacts are undesirable contaminants, and they cause interpretation complexity when analyzing the recorded neural activities. In this paper, we tried to mitigate the effects of the stimulation artifacts by developing a low-noise, double-sided optrode integrated with multiple Electromagnetic Shielding (EMS) layers. The LED and microelectrodes were constructed separately on the top epitaxial and bottom substrate layers, and EMS layers were used to separate the microelectrodes and LED to reduce signal cross-talks. Compared with conventional single-sided designs, in which the LED and microelectrodes are constructed on the same side, our results indicate that double-sided optrodes can significantly reduce the presence of stimulation artifacts. In addition, the presence of stimulation artifacts can further be reduced by decreasing the voltage difference and increasing the rise/fall time of the driving LED pulsed voltage. With all these strategies, the presence of stimulation artifacts was significantly reduced by ~76%. As well as stimulation suppression, the sapphire substrate also provided strong mechanical stiffness and support to the optrodes, as well as improved electronic stability, thus making the double-sided sapphire optrodes highly suitable for optogenetic neuroscience research on animal models.

31 August 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
JSJunyu Shen
Junyu Shen
YXYanyan Xu
Yanyan Xu
ZXZhengwen Xiao
Zhengwen Xiao
YLYuebo Liu
Yuebo Liu
HLHonghui Liu
Honghui Liu
BZBaijun Zhang
Baijun Zhang
Integrated optrodes for optogenetics have been becoming a significant tool in neuroscience through the combination of offering accurate stimulation to target cells and recording biological signals simultaneously. This makes it not just be widely used in neuroscience researches, but also have a great potential to be employed in future treatments in clinical neurological diseases. To optimize the integrated optrodes, this paper aimed to investigate the influence of surface material and illumination upon the performance of the microelectrode/electrolyte interface and build a corresponding evaluation system. In this work, an integrated planar optrode with a blue LED and microelectrodes was designed and fabricated. The charge transfer mechanism on the interface was theoretically modeled and experimentally verified. An evaluation system for assessing microelectrodes was also built up. Using this system, the proposed model of various biocompatible surface materials on microelectrodes was further investigated under different illumination conditions. The influence of illumination on the microelectrode/electrolyte interface was the cause of optical artifacts, which interfere the biological signal recording. It was found that surface materials had a great effect on the charge transfer capacity, electrical stability and recoverability, photostability, and especially optical artifacts. The metal with better charge transfer capacity and electrical stability is highly possible to have a better performance on the optical artifacts, regardless of its electrical recoverability and photostability under the illumination conditions of optogenetics. Among the five metals used in our investigation, iridium served as the best surface material for the proposed integrated optrodes. Thus, optimizing the surface material for optrodes could reduce optical interference, enhance the quality of the neural signal recording for optogenetics, and thus help to advance the research in neuroscience.

1 June 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
FWFengge Wang
Fengge Wang
HLHonghui Liu
Honghui Liu
YXYanyan Xu
Yanyan Xu
ZLZhiwen Liang
Zhiwen Liang
ZWZhisheng Wu
Zhisheng Wu
BZBaijun Zhang
Baijun Zhang
Human epidermal growth factor receptor-3 (HER-3) plays a key role in the growth and metastasis of cancer cells. The detection of HER-3 is very important for early screening and treatment of cancer. The AlGaN/GaN-based ion-sensitive heterostructure field effect transistor (ISHFET) is sensitive to surface charges. This makes it a promising candidate for the detection of HER-3. In this paper, we developed a biosensor for the detection of HER-3 with AlGaN/GaN-based ISHFET. The AlGaN/GaN-based ISHFET biosensor exhibits a sensitivity of 0.53 ± 0.04 mA/dec in 0.01 M phosphate buffer saline (1× PBS) (pH = 7.4) solution with 4% bovine serum albumin (BSA) at a source and drain voltage of 2 V. The detection limit is 2 ng/mL. A higher sensitivity (2.20 ± 0.15 mA/dec) can be achieved in 1× PBS buffer solution at a source and drain voltage of 2 V. The AlGaN/GaN-based ISHFET biosensor can be used for micro-liter (5 μL) solution measurements and the measurement can be performed after incubation of 5 min.

27 July 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
ZLZenghui Liu
Zenghui Liu
XZXiaobo Zhang
Xiaobo Zhang
ZLZhiwen Liang
Zhiwen Liang
FWFengge Wang
Fengge Wang
YXYanyan Xu
Yanyan Xu
BZBaijun Zhang
Baijun Zhang
GaN Schottky diodes show great potential in high-power terahertz frequency multipliers. The thermal characteristics of GaN Schottky diodes with single and double-row anode arrangements are described in this paper. The temperature distribution inside the Schottky diode is discussed in detail under the coupling condition of Joule heat and solid heat transfer. The effects of different substrates and substrate geometric parameters on the thermal characteristics of the Schottky diode chips with single and double-row anode arrangements are systematically analyzed. Compared with that of the chip with single-row anode arrangement, the maximum temperature of the chip with double-row anode arrangement can be reduced by 40 K at the same conditions. For chips with different substrates, chips with diamond substrates can withstand greater power dissipation when reaching the same temperature. The simulation results are instructive for the design and optimization of Schottky diodes in the terahertz field.