This in vitro study evaluated the effect of commercial whitening dentifrices on erosive tooth wear (ETW) of bovine enamel samples, in comparison with commercial regular dentifrices. Sixty bovine crowns were embedded in acrylic resin, polished and then had their baseline profile determined. They were randomly assigned to 5 groups (n=12/group), according to the type of commercial dentifrice to be tested: GI - Crest Anti-cavity Regular; GII - Crest 3D White; GIII - Colgate Total 12 Clean Mint; GIV - Colgate Optic White; GV - Placebo (negative control, fluoride-free dentifrice). The samples were submitted to daily erosive and abrasive challenges for 3 days. The erosive challenges were performed 3 times a day by immersing the specimens in 0.1% citric acid solution (pH 2.5) for 90 s. Each day after the first and last erosive challenges, the specimens were subjected to the abrasive challenge for 15 s, using a toothbrushing machine (Biopdi, São Carlos, SP, Brazil), soft toothbrushes and slurry (1:3 g/ml) of the tested toothpastes (1.5 N). The specimens were kept in artificial saliva between the challenges. The final profile was obtained and the ETW (µm) was calculated. Data were analyzed by Kruskal-Wallis and Dunn's tests (p<0.05). All dentifrices tested significantly reduced the enamel wear in comparison with the Placebo, except GIII. The median (95% CI) ETW was 1.35 (1.25-1.46)bc for GI, 1.17 (1.01-1.34)cd for GII, 1.36 (1.28-1.45)ab for GIII, 1.08 (1.04-1.14)d for GIV and 2.28 (2.18-2.39)a for GV. When dentifrices from the same manufacturer were compared, the whitening dentifrices led to similar or less wear than the regular ones.
To clinically assess the effect of desensitizing gels and dentifrices on the reduction in pain sensitivity and color variation during tooth bleaching. A total of 108 volunteers were randomly separated into the following groups of n=12: GT/S-glycerine and thickener/sucralose; NF/S-potassium nitrate and sodium fluoride/sucralose; NA/S-potassium nitrate and arginine/sucralose; GT/AC-glycerine and thickener/arginine and calcium carbonate; NF/AC-potassium nitrate and sodium fluoride/arginine and calcium carbonate; NA/AC-potassium nitrate and arginine/arginine and calcium carbonate; GT/PN-glycerine and thickener/potassium nitrate; NF/PN-potassium nitrate and sodium fluoride/potassium nitrate; and NA/PN-potassium nitrate and arginine/potassium nitrate. Sensitivity was assessed with the numerical analogue scale, and color variation (ΔE) was measured with a spectrophotometer. The sensitivity values obtained were subjected to a multivariate analysis of variance (MANOVA) and color variation values were subjected to a randomized analysis of variance (p<0.05). The NF/AC, NA/AC, NF/PN, and NA/PN groups presented lower sensitivity values and reduced sensitivity compared to those of the other groups throughout the clinical sessions. None of the groups showed sensitivity at the 24-week assessment. Statistically, no significant difference were observed in the color values among the groups four weeks after the beginning of bleaching (p=0.074). Additionally, the color assessment of all groups was statistically similar four weeks (p=0.084) and 24 weeks (p=0.118) after the beginning. Our results indicate that adding NF/S, NA/S, NF/AC, and NA/AC desensitizers to tooth bleaching protocols reduces pain sensitivity without affecting its effectiveness.
The effect of solutions containing a statherin-derived peptide (Stn15pSpS) on the protection against enamel erosion in vitro was evaluated. Bovine enamel specimens were divided into 4 groups (n = 15/group): (1) deionized water (negative control), (2) Elmex Erosion Protection™ (positive control), (3) 1.88 × 10−5 M Stn15pSpS, and (4) 3.76 × 10−5 M Stn15pSpS. The solutions were applied on the specimens for 1 min. Stimulated saliva was collected from 3 donors and used to form a 2-h acquired pellicle on the specimens. Then, the specimens were submitted to an erosive pH-cycling protocol 4 times/day, for 7 days (0.01 M HCl pH 2.0/45 s, artificial saliva/2 h, and artificial saliva overnight). The solutions were applied again during pH-cycling, 2 times/day for 1 min after the first and last erosive challenges. Enamel loss (μm) was assessed by contact profilometry. Data were analyzed by Kruskal-Wallis and Dunn’s test (p < 0.05). The best protection against erosion was conferred by Elmex Erosion Protection that significantly differed from all the other treatments, followed by the solutions containing Stn15pSpS, regardless of the concentration. However, 3.76 × 10−5 M Stn15pSpS did not differ from the negative control. The solution containing the lower concentration of Stn15pSpS protected against erosion in vitro, which should be confirmed using protocols that more closely resemble the clinical condition.
3 November 2022 in Journal of the Mechanical Behavior of Biomedical Materials